Jean-Francois Manceau

Prof. Jean-Francois Manceau

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2005 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
SAS. Alzuaga
S. Alzuaga
JMJean-Francois Manceau
Jean-Francois Manceau
FBF. Bastien
F. Bastien

8 July 2012 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
NTNathalie Tarchichi
Nathalie Tarchichi
Franck CholletFranck Chollet
Franck Chollet
JMJean-Francois Manceau
Jean-Francois Manceau

1 August 2012 in Mechatronics
Verified
Journal Article
Closed access
Réda YAHIAOUIRéda YAHIAOUI
Réda YAHIAOUI
RZRabah Zeggari
Rabah Zeggari
JMJulien Malapert
Julien Malapert
JMJean-Francois Manceau
Jean-Francois Manceau

29 September 2010 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
RZRabah Zeggari
Rabah Zeggari
Réda YAHIAOUIRéda YAHIAOUI
Réda YAHIAOUI
JMJulien Malapert
Julien Malapert
JMJean-Francois Manceau
Jean-Francois Manceau

22 October 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JBJonathan Bennes
Jonathan Bennes
SASebastien Alzuaga
Sebastien Alzuaga
FCFrederic Cherioux
Frederic Cherioux
SBSylvain Ballandras
Sylvain Ballandras
PVPascal Vairac
Pascal Vairac
FBFrancois Bastien
Francois Bastien
The capability to accurately handle liquids in small volumes is a key point for the development of lab-on-chip devices. In this paper, we investigate an application of surface acoustic waves (SAW) for positioning micro-droplets. A SAW device based on a 2 times 2 matrix of inter-digital transducers (IDTs) has been fabricated on a (YXl)/128deg LiNbO3 substrate, which implies displacement and detection in two dimensions of droplets atop a flat surface. Each IDT operates at a given frequency, allowing for an easy addressing of the active channel. Furthermore, very low cross-talk effects were observed as no frequency mixing arose in our device. Continuous as well as pulsed excitations of the IDTs have been studied, yielding, respectively, continuous and step-by-step droplet displacement modes. In addition, we also have used these two excitation types to control the velocity and the position of the droplets. We also have developed a theoretical analysis of the detection mode, which has been validated by experimental assessment.

12 February 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
GLGuillaume Laurent
Guillaume Laurent
ADAnne Delettre
Anne Delettre
RZRabah Zeggari
Rabah Zeggari
Réda YAHIAOUIRéda YAHIAOUI
Réda YAHIAOUI
JMJean-Francois Manceau
Jean-Francois Manceau
NFNadine Le Fort-Piat
Nadine Le Fort-Piat
The micro-conveyor is a 9 × 9 mm2 manipulation surface able to move millimeter-sized planar objects in the four cardinal directions using air flows. Thanks to a specific design, the air flow comes through a network of micro-channels connected to an array of micro-nozzles. Thus, the micro-conveyor generates an array of tilted air jets that lifts and moves the object in the required direction. In this paper, we characterize the device for transport and positioning tasks and evaluate its performances in terms of speed, resolution and repeatability. We show that the micro-conveyor is able to move the object with a speed up to 137 mm · s-1 in less than 100 ms whereas the positioning repeatability is around 17.7 μm with feedback control. The smallest step the object can do is 0.3 μm (positioning resolution). Moreover, we estimated thanks to a dynamic model that the speed could reach 456 mm· s-1 if several micro-conveyors were used to form a conveying line.