Modern non-invasive evaluation of Coronary Artery Disease (CAD) requires non-contrast low dose Computed Tomography (CT) imaging for determination of Calcium Scoring (CACS) and contrast-enhanced imaging for evaluation of vascular stenosis. Several methods for calculation of CACS from contrast-enhanced images have been proposed before. The main principle for that is generation of virtual non-contrast images by iodine subtraction from a contrast-enhanced spectral CT dataset. However, those techniques have some limitations: Dual-Source CT imaging can lead to increased radiation exposure, and switching of the tube voltage (rapid kVp switching) can be associated with slower rotation speed of the gantry and is thus prone to motion artefacts that are especially critical in cardiac imaging. Both techniques cannot simultaneously acquire spectral data. A novel technique to overcome these difficulties is spectral imaging with a dual-layer detector. After absorption of the lower energetic photons in the first layer, the second layer detects a hardened spectrum of the emitted radiation resulting in registration of two different energy spectra at the same time. The objective of the present investigation was to evaluate the accuracy of virtual non-contrast CACS computed from spectral data in comparison to standard non-contrast imaging. We consecutively investigated 20 patients referred to Coronary Computed Tomography Angiography (CCTA) with suspicion of CAD using a Dual-Layer spectral CT system (IQon; Philips Healthcare, The Netherlands). CACS was calculated from both, real- and virtual non-contrast images by certified software for medical use. Correlation analyses for real- and virtual non-contrast images and agreement evaluation with Bland-Altman-Plots were performed. Mean patient age was 57.7 ± 14 years (n = 20). 13 patients (65%) were male. Inter-quartile-range of clinical CACS was 0–448, the mean was 334. Correlation of CACS from real- and virtual non-contrast images was very high (0.94); p < 0.0001. The slope was 2.3 indicating that values from virtual non-contrast images are approximately half of the results obtained from real non-contrast data. Visual analysis of Bland-Altman-Plot shows good accordance of both methods when results from virtual non-contrast data are multiplied by the slope of the logistic regression model (2.3). The acquired power of this results is 0.99. Determination of Calcium Score from contrast enhanced CCTA using spectral imaging with a dual-layer detector is feasible and shows good agreement with the conventional technique when a proportionality factor is applied. The observed difference between both methods is due to an underestimation of plaque volume, and—to an even greater extend -an underestimation of plaque density with the virtual non-contrast approach. Our data suggest that radiation exposure can be reduced through omitting additional native scans for patients referred to CCTA when using a dual-layer spectral system without the usual limitations of dual energy analysis.
2 July 2014 in The International Journal of Cardiovascular Imaging
Area at risk (AAR) is an important parameter for the assessment of the salvage area after revascularization in acute myocardial infarction (AMI). By combining AAR assessment by T2-weighted imaging and scar quantification by late gadolinium enhancement imaging cardiovascular magnetic resonance (CMR) offers a promising alternative to the “classical” modality of Tc99m-sestamibi single photon emission tomography (SPECT). Current T2 weighted sequences for edema imaging in CMR are limited by low contrast to noise ratios and motion artifacts. During the last years novel CMR imaging techniques for quantification of acute myocardial injury, particularly the T1-mapping and T2-mapping, have attracted rising attention. But no direct comparison between the different sequences in the setting of AMI or a validation against SPECT has been reported so far. We analyzed 14 patients undergoing primary coronary revascularization in AMI in whom both a pre-intervention Tc99m-sestamibi-SPECT and CMR imaging at a median of 3.4 (interquartile range 3.3–3.6) days after the acute event were performed. Size of AAR was measured by three different non-contrast CMR techniques on corresponding short axis slices: T2-weighted, fat-suppressed turbospin echo sequence (TSE), T2-mapping from T2-prepared balanced steady state free precession sequences (T2-MAP) and T1-mapping from modified look locker inversion recovery (MOLLI) sequences. For each CMR sequence, the AAR was quantified by appropriate methods (absolute values for mapping sequences, comparison with remote myocardium for other sequences) and correlated with Tc99m-sestamibi-SPECT. All measurements were performed on a 1.5 Tesla scanner. The size of the AAR assessed by CMR was 28.7 ± 20.9 % of left ventricular myocardial volume (%LV) for TSE, 45.8 ± 16.6 %LV for T2-MAP, and 40.1 ± 14.4 %LV for MOLLI. AAR assessed by SPECT measured 41.6 ± 20.7 %LV. Correlation analysis revealed best correlation with SPECT for T2-MAP at a T2-threshold of 60 ms (ms) (slope = 0.99, Pearson’s r = 0.94), and for MOLLI at T1-threshold of 1,075 ms (slope 0.86, r = 0.91, Pearson’s r = 0.45). For the assessment of AAR in AMI, the novel T2-mapping technique correlates best with SPECT size, T1-mapping with MOLLI and standard T2-weighted imaging showed similar good correlations.
13 August 2018 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Background Blood flow through the cavities of the heart and great vessels is pulsatile and is subject to time and multidirectional variations. To date, the recording of blood flow in multiple directions and phases has been limited. 4D-flow MRI offers advantages for the recording, visualization and analysis of blood flow. Method The status quo of the method was summarized through analysis with the PubMed database using the keywords “4D-flow MRI, phase-contrast magnetic resonance imaging, MR flow imaging/visualization, MR flow quantification, 3 D cine (time-resolved) phase-contrast CMR, three-directional velocity-encoding MRI”. Results/Conclusion This review summarizes the current status of the technical development of 4D-flow MRI, discusses its advantages and disadvantages and describes clinical applications. Finally, the most important principles and parameters are explained to give the reader relevant information about clinical indications, postprocessing methods and limitations of the method. Key Points: Citation Format
Trans-arterial radioembolization (TARE) is increasingly evaluated for unresectable intrahepatic cholangiocarcinoma (ICC). Not all ICC patients benefit equally well from TARE. Therefore, we sought to evaluate variables predicting progression-free survival (PFS) and overall survival (OS). Patients with non-resectable ICC underwent TARE and were treated with 90Y resin microspheres. Baseline characteristics, biochemical/clinical toxicities, and response were examined for impact on PFS and OS. A total of 103 treatments were administered to 73 patients without major complications or toxicity. Mean OS was 18.9 months (95% confidence intervals (CI); 13.9–23.9 months). Mean and median PFS were 10.1 months (95% CI; 7.9–12.2) and 6.4 months (95% CI; 5.20–7.61), respectively. Median OS and PFS were significantly prolonged in patients with baseline cholinesterase (CHE) ≥ 4.62 kU/L (OS: 14.0 vs. 5.5 months; PFS: 6.9 vs. 3.2 months; p < 0.001). Patients with a tumor burden ≤ 25% had a significantly longer OS (15.2 vs. 6.6 months; p = 0.036). Median PFS was significantly longer for patients with multiple TARE cycles (24.4 vs. 5.8 months; p = 0.04). TARE is a considerable and safe option for unresectable ICC. CA-19-9, CHE, and tumor burden have predictive value for survival in patients treated with TARE. Multiple TARE treatments might further improve survival; this has to be confirmed by further studies.
23 November 2016 in The International Journal of Cardiovascular Imaging