Maurizio Del Greco

Prof. Maurizio Del Greco

Santa Maria del Carmine Hospital Rovereto
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2017 in EP Europace
Verified
Journal Article
Closed access
PDF file
MMMassimiliano Maines
Massimiliano Maines
Alessandro ZorziAlessandro Zorzi
Alessandro Zorzi
GTGiancarlo Tomasi
Giancarlo Tomasi
CACarlo Angheben
Carlo Angheben
DCDomenico Catanzariti
Domenico Catanzariti
MGMaurizio Del Greco
Maurizio Del Greco
Implantable loop recorders (ILR) are indicated in a variety of clinical situations when extended cardiac rhythm monitoring is needed. We aimed to assess the clinical impact, safety, and accuracy of the new Medtronic Reveal LINQTM ILR that can be inserted outside the electrophysiology (EP) laboratory and remotely monitored. All 154 consecutive patients (100 males, 63 ± 15 year-old) who received the Reveal LINQTM ILR during the period July 2014–June 2016 were enrolled. The device was implanted in a procedure room and all patients where provided with the MyCareLinkTM remote monitoring system. Data were reviewed every working day via the Carelink® web system by a specialist nurse who, in case of significant events, consulted an electrophysiologist. During a mean follow-up of 12.1 (6.7–18.4) months (range 2–24 months), a diagnosis was made in 99 (64%) patients and in 60 (39%) ≥1 therapeutic interventions were established following recording of arrhythmias. In 26 of these 60 patients, remote monitoring prompted therapeutic interventions following asymptomatic arrhythmic events 3.8 months before the next theoretical scheduled in-office data download. False bradycardia detection for undersensing occurred in 44 (29%) patients and false tachycardia detection for oversensing in 4 (3%). One patient experienced skin erosion requiring explantation and none suffered from infection. The remote monitoring feature of the Reveal LINQTM allowed earlier diagnosis of asymptomatic but serious arrhythmias in a significant proportion of patients. Implantation of the device outside the EP laboratory appeared safe. However, R-wave undersensing and consequent false recognition of bradyarrhythmias remains a clinically important technical issue.

9 November 2016 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
MGMaurizio Del Greco
Maurizio Del Greco
MMMassimiliano Maines
Massimiliano Maines
MMMassimiliano Marini
Massimiliano Marini
ACAndrea Colella
Andrea Colella
MZMassimo Zecchin
Massimo Zecchin
Alessandro ZorziAlessandro Zorzi
Alessandro Zorzi

10 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Massimiliano MainesMassimiliano Maines
Massimiliano Maines
PPPietro Palmisano
Pietro Palmisano
MGMaurizio Del Greco
Maurizio Del Greco
DMDonato Melissano
Donato Melissano
SBSilvana De Bonis
Silvana De Bonis
Giuseppe BorianiGiuseppe Boriani
Giuseppe Boriani
The COVID-19 pandemic has had a profound impact on the organisation of health care in Italy, with an acceleration in the development of telemedicine. To assess the impact of the COVID-19 pandemic on the spread of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) in Italy, a survey addressed to cardiologists operating in all Italian CIED-implanting centres was launched. A total of 127 cardiologists from 116 Italian arrhythmia centres took part in the survey, 41.0% of all 283 CIED-implanting centres operating in Italy in 2019. All participating centres declared to use RM of CIEDs. COVID-19 pandemic resulted in an increase in the use of RM in 83 (71.6%) participating centres. In a temporal perspective, an increase in the median number of patients per centre followed up by RM was found from 2012 to 2017, followed by an exponential increase from 2017 to 2020. In 36 participating centres (31.0%) a telehealth visits service was activated as a replacement for in-person outpatient visits (in patients with or without CIED) during the COVID-19 pandemic. COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs and in the use of telemedicine in the clinical practice of cardiology.

5 May 2020 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
GSGiuseppe Stabile
Giuseppe Stabile
ALAntoine Lepillier
Antoine Lepillier
ERErmenegildo De Ruvo
Ermenegildo De Ruvo
MSMarco Scaglione
Marco Scaglione
MAMatteo Anselmino
Matteo Anselmino
FSFrancesco Solimene
Francesco Solimene

1 December 2020 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
SSSimone Stella
Simone Stella
CVChristian Vergara
Christian Vergara
Massimiliano MainesMassimiliano Maines
Massimiliano Maines
DCDomenico Catanzariti
Domenico Catanzariti
PAPasquale Claudio Africa
Pasquale Claudio Africa
AQAlfio Quarteroni
Alfio Quarteroni