The collapse of overhead power line guyed towers is one of the leading causes of power grid failures, subjecting electricity companies to pay considerable, high-value fines. In this way, the current work proposes a novel and complete framework for the remote monitoring of mechanical stresses in guyed towers. The framework method comprises a mesh network for data forwarding and neural networks to improve the performance of Low-Power and Lossy Networks. The method also considers the use of multiple sensors in the sensor fusion technique. As a result, the risk of collapse of guyed cable towers reduces, due to the remote monitoring and preventive actions promoted by the framework. Furthermore, the proposed method uses multiple input variable fusions, such as accelerometers and tension sensors, to estimate the tower’s displacement. These estimations help address the structural health of the tower against failures (i.e., loosening of the stay cables, displacement, and vibrations) that can cause catastrophic events, such as tower collapse or even cable rupture.
This paper presents the development of a methodology to detect and evaluate faults in cable-stayed towers, which are part of the infrastructure of Brazil’s interconnected electrical system. The proposed method increases system reliability and minimizes the risk of service failure and tower collapse through the introduction of predictive maintenance methods based on artificial intelligence, which will ultimately benefit the end consumer. The proposed signal processing and interpretation methods are based on a machine learning approach, where the tower vibration is acquired from accelerometers that measure the dynamic response caused by the effects of the environment on the towers through wind and weather conditions. Data-based models were developed to obtain a representation of health degradation, which is primarily based on the finite element model of the tower, subjected to wind excitation. This representation is also based on measurements using a mockup tower with different types of provoked degradation that was subjected to ambient changes in the laboratory. The sensor signals are preprocessed and submitted to an autoencoder neural network to minimize the dimensionality of the resources involved, being analyzed by a classifier, based on a Softmax configuration. The results of the proposed configuration indicate the possibility of early failure detection and evolution evaluation, providing an effective failure detection and monitoring system.
This paper introduces a new hyperspectral image (HSI) denoising method called Non-local Convolutional Neural Network Denoiser (NL-CNND). The technique exploits data in four bands adjacent to the target one as additional information for the restoring process, and it uses a pre-denoising step based on BM4D. All the bands paired with their pre-denoised versions in a second step feed a Convolutional Neural Network. To network generalization, one of the inputs is the noise level of the input image, allowing a single model to work with different noise levels. This restoration technique overcomes quality when compared to current eight classical and neural methods. The results show higher PSNR, SSIM, and SAM metrics than all the other restoration methods, surpassing those achieved using BM4D alone. Besides, the results show a higher level of detail visually while at the same time reducing over-smoothing on the input images’ features. The paper also includes an algorithm for complete image restoration, allowing for denoising full-sized HSIs independent of their shape. The dataset creation used for network training is detailed, based on a small set of available hyperspectral images, encompassing data normalization, conversion, and storage.
This article proposes a methodology for monitoring the structural stability of each tower of an electric power transmission line through sensor measurements which estimates the different situations that may indicate the need for intervention to prevent the structure collapsing. The extended Kalman filter was adopted to predict the failures, considering sensor fusion techniques such as the displacements of the upper central position of the tower above certain limits. The load of the stay cables is calculated from the natural frequencies, which are determined by the accelerometers connected to the cables. The average value of these forces, which must be higher than a normal limit, were calculated to predict a failure. All guyed towers of a power transmission line thousands of kilometers long will be individually monitored considering the methodology described in this study, which makes this article one of the first relevant research studies in this area. Typically, guyed towers must often be manually inspected to ensure that the stay cables have acceptable pretension to prevent a lack of stability in the transmission line towers.
This work presents a new unit cell electromagnetic bandgap (EBG) design based on HoneyComb geometry (HCPBG). The new HCPBG takes a uniplanar geometry (UCPBG—uniplanar compact PBG) as a reference and follows similar design methods for defining geometric parameters. The new structure’s advantages consist of reduced occupied printed circuit board area and flexible rejection band properties. In addition, rotation and slight geometry modification in the HCPBG cell allow changing the profile of the attenuation frequency range. This paper also presents a reconfigurable unit cell HCPBG filter strategy, for which the resonance center frequency is shifted by changing the gap capacitance with the assistance of varactor diodes. The HCPBG filter and reconfiguration behavior is demonstrated through electromagnetic (EM) simulations over the FR1 band of the 5G communication network. Intelligent communication systems can use the reconfiguration feature to select the optimal operating frequency for maximum attenuation of unwanted or interfering signals, such as harmonics or intermodulation products.