Han Yan

Mr. Han Yan


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
LLLei Luo
Lei Luo
HYHan Yan
Han Yan
WDWei Du
Wei Du
LHLeyi Hou
Leyi Hou
YFYao Fu
Yao Fu
SWSongtao Wang
Songtao Wang
Film holes are extensively utilized to protect the blade external surface by ejecting coolant, forming a protective film, and separating the hot gas and blade surface. Trenched holes, caused by the turbine blade coated with thermal barrier, greatly feature better film cooling performance than traditional cylinder holes. In this study, the effects of a rib-disturbed feed flow on the film cooling performance of trenched holes are studied through the numerical method. Two typical rib attacking angles, 45° and 135°, are compared with the blowing ratio increasing from 0.5 to 2.0. The effects of the curved surface (convex and concave) are also included. Numerical results prove that film effectiveness with the coolant fed by the rib-disturbed internal flow is sensitive to the blowing ratio. The rib-turbulated cooling flow entering the film hole is featured with different swirling states; therefore, the interaction between the mainstream and the cooling air of varied swirling state leads to different film coverage and effectiveness. Overall, 135° ribs induce better adiabatic film cooling effectiveness than 45° ribs, with a maximum improvement 34.9% at M = 0.5. Film effectiveness on the convex surface is better than that on flat and concave surfaces. Area-averaged η on convex and concave surfaces is, respectively, 4.7% higher and 6.2% lower than that on the flat surface. Normal pressure gradient established on the convex surface contributes to reducing the turbulence intensity and improving the film lateral coverage.

28 December 2024 in Energy
Verified
Journal Article
Closed access
QLQianqian Luo
Qianqian Luo
LLLei Luo
Lei Luo
WDWei Du
Wei Du
QJQianKun Jia
QianKun Jia
HYHan Yan
Han Yan

9 July 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HYHan Yan
Han Yan
ZCZilong Chen
Zilong Chen
FZFei Zeng
Fei Zeng
LLLei Luo
Lei Luo
WDWei Du
Wei Du
LGLicheng Guo
Licheng Guo

12 June 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
QJQiankun Jia
Qiankun Jia
WDWei Du
Wei Du
XLXingchen Li
Xingchen Li
LLLei Luo
Lei Luo
YJYinghou Jiao
Yinghou Jiao
HYHan Yan
Han Yan

1 February 2024 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
HZHaimeng Zhou
Haimeng Zhou
LLLei Luo
Lei Luo
WDWei Du
Wei Du
HYHan Yan
Han Yan
SWSongtao Wang
Songtao Wang
The squealer tip is acknowledged as an effective and dependable design for minimizing leakage loss and reducing thermal load in high-pressure turbine blades. After confirming the numerical approach, this study explored the cooling and aerodynamic characteristics of a novel cooling protection scheme with rail crown holes in a squealer tip. The rail crown hole parameters including the hole number, size, and distribution are research variable. Evaluation indexes of cooling and aerodynamic performance are the tip surface adiabatic film cooling efficiency (η) and clearance leakage flow rate (LFR). In cooling aspects, increasing the hole number or the hole size can improve the coolant attachment to the rail crown surface under the same coolant mass flow rate (Q). The coolant distribution within the cavity is substantially improved by concentrating the film holes at the leading-edge rail, which enhances the cooling protection of the cavity floor. In aerodynamic aspects, at low Q conditions, the total LFR correlates only with Q and is less sensitive to hole parameters. At high Q conditions, enlarging the hole size proves more effective in suppressing total LFR. Additionally, three cases with optimal cooling effects are chosen to investigate the impact of Q. These three cases are the scheme with an increasing hole number (case 1), the scheme with an enlarging hole size (case 4), and the scheme with concentrated holes at the leading edge (case 5). The results show that case 5 consistently exhibits superior cooling protection for the cavity floor in all Q conditions. For average η of the rail crown surface, cases 1 and 5 reach the peak value of average η at Q = 1.0Q0, while case 4 attains its peak value at Q = 1.5Q0.

5 November 2018 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
LLLei Luo
Lei Luo
HYHan Yan
Han Yan
WDWei Du
Wei Du
SWSongtao Wang
Songtao Wang
CLChanghai Li
Changhai Li
XZXinghong Zhang
Xinghong Zhang
In this study, numerical simulations are conducted to investigate the effects of pin fin and dimple shape on the flow structure and heat transfer characteristics in a rectangular channel. The studied shapes for dimple and pin fin are circular, spanwise-elliptical, and streamwise-elliptical, respectively. The flow structure, friction factor, and heat transfer performance are obtained and analyzed with Reynolds number ranging from 10,000 to 50,000. Channel with circular pin fin and dimple is chosen as the Baseline. Channels with spanwise-elliptical pin fins have the best heat transfer augmentation, while also accompanied with the largest friction factor. Spanwise-elliptical pin fin generates the strongest horseshoe vortex which is responsible for the best heat transfer augmentation. Besides, channels with streamwise-elliptical pin fins show the worst heat transfer augmentation and the smallest friction factors. Dimple plays an important role in improving the heat transfer. Spanwise-elliptical dimple yields the best heat transfer augmentation which is attributed to the strongest counter-rotating vortex, while streamwise-elliptical dimple shows the worst heat transfer enhancement.