Giuseppe Battistoni

Prof. Giuseppe Battistoni

INFN Milano and Pysics Department Milano University
+1
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VFVeronica Ferrero
Veronica Ferrero
EFElisa Fiorina
Elisa Fiorina
MMMatteo Morrocchi
Matteo Morrocchi
FPFrancesco Pennazio
Francesco Pennazio
GBGuido Baroni
Guido Baroni
MBMaria Giuseppina Bisogni
Maria Giuseppina Bisogni
Particle therapy exploits the energy deposition pattern of hadron beams. The narrow Bragg Peak at the end of range is a major advantage but range uncertainties can cause severe damage and require online verification to maximise the effectiveness in clinics. In-beam Positron Emission Tomography (PET) is a non-invasive, promising in-vivo technique, which consists in the measurement of the β+ activity induced by beam-tissue interactions during treatment, and presents the highest correlation of the measured activity distribution with the deposited dose, since it is not much influenced by biological washout. Here we report the first clinical results obtained with a state-of-the-art in-beam PET scanner, with on-the-fly reconstruction of the activity distribution during irradiation. An automated time-resolved quantitative analysis was tested on a lacrimal gland carcinoma case, monitored during two consecutive treatment sessions. The 3D activity map was reconstructed every 10 s, with an average delay between beam delivery and image availability of about 6 s. The correlation coefficient of 3D activity maps for the two sessions (above 0.9 after 120 s) and the range agreement (within 1 mm) prove the suitability of in-beam PET for online range verification during treatment, a crucial step towards adaptive strategies in particle therapy.

2 December 2024 in EPJ Nuclear Sciences & Technologies
Verified
Journal Article
Open access
PDF file
FBFrancesca Ballarini
Francesca Ballarini
KBKonstantin Batkov
Konstantin Batkov
GBGiuseppe Battistoni
Giuseppe Battistoni
MBMaria Bisogni
Maria Bisogni
TBTill Tobias Tobias Böhlen
Till Tobias Tobias Böhlen
LZLorenzo Zana
Lorenzo Zana
The FLUKA Monte Carlo Radiation Transport and Interaction code package is widely used to simulate the interaction of particles with matter in a variety of fields, including high energy physics, space radiation, medical applications, radiation protection and shielding assessments, accelerator studies, astrophysical studies and well logging. This paper gives a brief overview of the FLUKA program and describes recent developments, in particular, improvements in the modelling of particle interactions and transport are described in detail. In addition, an overview of selected applications is given.

17 June 2011 in Medical Physics
Verified
Journal Article
Closed access
PDF file
FBF. Botta
F. Botta
AMA. Mairani
A. Mairani
GBGiuseppe Battistoni
Giuseppe Battistoni
MCM. Cremonesi
M. Cremonesi
ADA. Di Dia
A. Di Dia
MVMauro Valente
Mauro Valente

3 August 2016 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
SMSilvia Muraro
Silvia Muraro
GBGiuseppe Battistoni
Giuseppe Battistoni
FCFrancesco Collamati
Francesco Collamati
ELErika De Lucia
Erika De Lucia
RFRiccardo Faccini
Riccardo Faccini
VPVincenzo Patera
Vincenzo Patera
The interaction of the incoming beam radiation with the patient body in hadrontherapy treatments produces secondary charged and neutral particles, whose detection can be used for monitoring purposes and to perform an on-line check of beam particle range. In the context of ion-therapy with active scanning, charged particles are potentially attractive since they can be easily tracked with a high efficiency, in presence of a relatively low background contamination. In order to verify the possibility of exploiting this approach for in-beam monitoring in ion-therapy, and to guide the design of specific detectors, both simulations and experimental tests are being performed with ion beams impinging on simple homogeneous tissue-like targets (PMMA). From these studies, a resolution of the order of few millimeters on the single track has been proven to be sufficient to exploit charged particle tracking for monitoring purposes, preserving the precision achievable on longitudinal shape. The results obtained so far show that the measurement of charged particles can be successfully implemented in a technology capable of monitoring both the dose profile and the position of the Bragg peak inside the target and finally lead to the design of a novel profile detector. Crucial aspects to be considered are the detector positioning, to be optimized in order to maximize the available statistics, and the capability of accounting for the multiple scattering interactions undergone by the charged fragments along their exit path from the patient body. The experimental results collected up to now are also valuable for the validation of Monte Carlo simulation software tools and their implementation in Treatment Planning Software packages.

26 February 2021 in Biology
Verified
Journal Article
Open access
PDF file
IPIan Postuma
Ian Postuma
SGSara González
Sara González
MHMaria S Herrera
Maria S Herrera
LPLucas Provenzano
Lucas Provenzano
MFMichele Ferrarini
Michele Ferrarini
Silva BortolussiSilva Bortolussi
Silva Bortolussi
(1) Background:The quality of neutron beams for Boron Neutron Capture Therapy (BNCT) is currently defined by its physical characteristics in air. Recommendations exist to define whether a designed beam is useful for clinical treatment. This work presents a new way to evaluate neutron beams based on their clinical performance and on their safety, employing radiobiological quantities. (2) Methods: The case study is a neutron beam for deep-seated tumors from a 5 MeV proton beam coupled to a beryllium target. Physical Figures of Merit were used to design five beams; however, they did not allow a clear ranking of their quality in terms of therapeutic potential. The latter was then evaluated based on in-phantom dose distributions and on the calculation of the Uncomplicated Tumor Control Probability (UTCP). The safety of the beams was also evaluated calculating the in-patient out-of-beam dosimetry. (3) Results: All the beams ensured a UTCP comparable to the one of a clinical beam in phantom; the safety criterion allowed to choose the best candidate. When this was tested in the treatment planning of a real patient treated in Finland, the UTCP was still comparable to the one of the clinical beam. (4) Conclusions: Even when standard physical recommendations are not met, radiobiological and dosimetric criteria demonstrate to be a valid tool to select an effective and safe beam for patient treatment.

17 May 2021 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
LFLuigi Faillace
Luigi Faillace
SBS. Barone
S. Barone
GBGiuseppe Battistoni
Giuseppe Battistoni
MFM. Di Francesco
M. Di Francesco
GFGiuseppe Felici
Giuseppe Felici
MMM. Migliorati
M. Migliorati
Radiation therapy is currently the most utilized technique for the treatment of tumors by means of ionizing radiation, such as electrons, protons and x/gamma rays, depending on the type, size and depth of the cancer mass. Radiation therapy has in general fulfilled the main requirement of targeting thus damaging the malignant cells and sparing the healthy tissues as best as possible. In this scenario, electron linear accelerators have been operated as viable tools for the delivery of both high-energetic electrons and x-ray beams, which are obtained via the bremsstrahlung process of the electrons hitting on a high-Z material. Recently, it has been experimentally demonstrated that ultrahigh dose-rate bursts of electrons and x-ray beams increase the differential response between healthy and tumor tissues. This beneficial response is referred to as the FLASH effect. For this purpose, we have developed the first dedicated compact S-band linear accelerator for FLASH radiotherapy. This linac is optimized for a nominal energy of 7 MeV and a pulsed electron beam current of 100 mA and above. The accelerator is mounted on a remote-controlled system for preclinical research studies in the FLASH regime. We will show the rf and beam dynamics design of the S-band linac as well as the commissioning and high-power rf tests. Furthermore, the results of the dosimetric measurements will be illustrated.