Bin Zheng

Dr. Bin Zheng

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2012 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
BZBin Zheng
Bin Zheng
XJXianta Jiang
Xianta Jiang
GTGeoffrey Tien
Geoffrey Tien
AMAdam Meneghetti
Adam Meneghetti
OPO. Neely M. Panton
O. Neely M. Panton
MAM. Stella Atkins
M. Stella Atkins

26 June 2012 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
RKRana S. A. Khan
Rana S. A. Khan
GTGeoffrey Tien
Geoffrey Tien
MAM. Stella Atkins
M. Stella Atkins
BZBin Zheng
Bin Zheng
OPOrmond N. M. Panton
Ormond N. M. Panton
AMAdam T. Meneghetti
Adam T. Meneghetti

13 May 2021 in Frontiers in Computer Science
Verified
Journal Article
Open access
PDF file
XLXin Liu
Xin Liu
CZChen Zhao
Chen Zhao
BZBin Zheng
Bin Zheng
QGQinwei Guo
Qinwei Guo
XDXiaoqin Duan
Xiaoqin Duan
DZDezheng Zhang
Dezheng Zhang
In this study, we review the role of wearable devices in tracking our daily locomotion. We discuss types of wearable devices that can be used, methods for gait analyses, and multiple healthcare-related applications aided by artificial intelligence. Impaired walking and locomotion are common resulting from injuries, degenerative pathologies, musculoskeletal disorders, and various neurological damages. Daily tracking and gait analysis are convenient and efficient approaches for monitoring human walking, where concreate and rich data can be obtained for examining our posture control mechanism during body movement and providing enhanced clinical pieces of evidence for diagnoses and treatments. Many sensors in wearable devices can help to record data of walking and running; spatiotemporal and kinematic variables can be further calculated in gait analysis. We report our previous works in gait analysis, discussing applications of wearable devices for detecting foot and ankle lesions, supporting surgeons in early diagnosis, and helping physicians with rehabilitation.

9 July 2016 in Surgical Innovation
Verified
Journal Article
Closed access
RBRositsa Bogdanova
Rositsa Bogdanova
PBPierre Boulanger
Pierre Boulanger
BZBin Zheng
Bin Zheng
Minimally invasive surgery (MIS) poses visual challenges to the surgeons. In MIS, binocular disparity is not freely available for surgeons, who are required to mentally rebuild the 3-dimensional (3D) patient anatomy from a limited number of monoscopic visual cues. The insufficient depth cues from the MIS environment could cause surgeons to misjudge spatial depth, which could lead to performance errors thus jeopardizing patient safety. In this article, we will first discuss the natural human depth perception by exploring the main depth cues available for surgeons in open procedures. Subsequently, we will reveal what depth cues are lost in MIS and how surgeons compensate for the incomplete depth presentation. Next, we will further expand our knowledge by exploring some of the available solutions for improving depth presentation to surgeons. Here we will review the innovative approaches (multiple 2D camera assembly, shadow introduction) and devices (3D monitors, head-mounted devices, and auto-stereoscopic monitors) for 3D image presentation from the past few years.

9 March 2015 in Surgical Innovation
Verified
Journal Article
Closed access
BZBin Zheng
Bin Zheng
XJXianta Jiang
Xianta Jiang
MAM. Stella Atkins
M. Stella Atkins
Background. Assessing the workload of surgeons requires technology to continuously monitor surgeons’ behaviors without interfering with their performance. We investigated the feasibility of using eye-tracking to reveal surgeons’ response to increasing task difficulty. Methods. A controlled study was conducted in a simulated operating room, where 14 subjects were required to perform a laparoscopic procedure that includes 9 subtasks. The subtasks could be divided into 3 types with different levels of task difficulty, calculated by the index of task difficulty (ID) proposed by Fitts in 1954. Pupillary responses of subjects in performing the procedure were recorded using Tobii eye-tracking equipment. Peak pupil dilation and movement time were compared between subtasks with different IDs as well as between fast moving and slow aiming phases within each subtask. Results. When the task difficulty was increased, task completion time increased. Meanwhile, the subjects’ peak pupil size also increased. As the entire procedure was performed continuously, we found that pupil responses were not only affected by the ID in the current subtask but also influenced by subtasks before and after. Discussion. Decomposing a surgical procedure into meaningful subtasks and examining the surgeon’s pupil response to each subtask enables us to identify the challenging steps within a continuous surgical procedure. Psychomotor evidence on surgeon’s performance may lead to an innovation for designing a task-specific training curriculum.

29 September 2020 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
SLShang Lu
Shang Lu
YPYerly Paola Sanchez Perdomo
Yerly Paola Sanchez Perdomo
XJXianta Jiang
Xianta Jiang
BZBin Zheng
Bin Zheng