High efficiency air filtration has been suggested to reduce airborne transmission of ‘infectious’ aerosols. In this study the ‘air cleaning’ effect as well as the effect on sound and air velocity (draught risk) of a mobile High-Efficiency Particulate Air (HEPA) filter system was tested for different settings and positions in the Experience room of the SenseLab. From both the noise assessments by a panel of subjects and sound monitoring it was concluded that the mobile HEPA filter system causes an unacceptable background sound level in the tested classroom setting (Experience room). With respect to the air velocity measurements and draught rating calculations, it was concluded that both depend on the position and the setting of the HEPA filter system as well as on the position and height of the measurements. For the removal of aerosols simulated by air-filled soap bubbles in front of the subject, the mobile HEPA filter system performed better as compared to the ‘No ventilation’ regime, for all settings and both positions, and for some settings, even better than all the tested mixing ventilation regimes. The use of a mobile HEPA filter system seems a good additional measure when only natural ventilation options are available. Future research should focus on rooms of different sizes or shapes, as this may also play a role in the filter's performance, noise and draught effects.
Since the COVID-19 pandemic, the ventilation of school buildings has attracted considerable attention from the general public and researchers. However, guidance to assess the ventilation performance in classrooms, especially during a pandemic, is still lacking. Therefore, aiming to fill this gap, this study conducted a full-scale laboratory study to monitor the CO2 concentrations at 18 locations in a classroom setting under four different ventilation regimes. Additionally, a field study was carried out in two Dutch secondary schools to monitor the CO2 concentrations in the real classrooms with different ventilation regimes. Both the laboratory and field study findings showed that CO2 concentrations varied a lot between different locations in the same room, especially under natural ventilation conditions. The outcome demonstrates the need of monitoring the CO2 concentration at more than one location in a classroom. Moreover, the monitored CO2 concentration patterns for different ventilation regimes were used to determine the most representative location for CO2 monitoring in classrooms. For naturally ventilated classrooms, the location on the wall opposite to windows and the location on the front wall (nearby the teacher) were recommended. For mechanically ventilated classrooms, one measurement location seemed enough because CO2 was well-mixed under this ventilation regime.
During the COVID-19 pandemic, the importance of ventilation was widely stressed and new protocols of ventilation were implemented in school buildings worldwide. In the Netherlands, schools were recommended to keep the windows and doors open, and after a national lockdown more stringent measures such as reduction of occupancy were introduced. In this study, the actual effects of such measures on ventilation and thermal conditions were investigated in 31 classrooms of 11 Dutch secondary schools, by monitoring the indoor and outdoor CO2 concentration and air temperature, both before and after the lockdown. Ventilation rates were calculated using the steady-state method. Pre-lockdown, with an average occupancy of 17 students, in 42% of the classrooms the CO2 concentration exceeded the upper limit of the Dutch national guidelines (800 ppm above outdoors), while 13% had a ventilation rate per person (VRp) lower than the minimum requirement (6 l/s/p). Post-lockdown, the indoor CO2 concentration decreased significantly while for ventilation rates significant increase was only found in VRp, mainly caused by the decrease in occupancy (average 10 students). The total ventilation rate per classrooms, mainly induced by opening windows and doors, did not change significantly. Meanwhile, according to the Dutch national guidelines, thermal conditions in the classrooms were not satisfying, both pre- and post-lockdown. While opening windows and doors cannot achieve the required indoor environmental quality at all times, reducing occupancy might not be feasible for immediate implementation. Hence, more controllable and flexible ways for improving indoor air quality and thermal comfort in classrooms are needed.
Because of COVID-19, the indoor environmental quality (IEQ) in sports facilities has been a concern to environmental health practitioners. To develop an overall understanding of the available guidelines and standards and studies performed on IEQ in sports facilities, an extensive literature study was conducted, with the aim of identifying: (1) indicators that are being used to assess IEQ in different sports facilities; (2) indicators that are potentially interesting to be used to assess indoor air, in particular; (3) gaps in knowledge to determine whether sports facilities are safe, healthy and comfortable for people to stay and perform their activities. The outcome indicates that most current standards and previous investigations on IEQ in sports facilities mainly focused on dose-related indicators (such as ventilation rate), while building-related indicators (such as ventilation regime) and occupant-related indicators (such as IEQ preferences) were rarely considered. Little attention is given to the fact that ventilation systems may play an important role in the air quality of the location, and few investigations have been performed on the transmission of SARS-CoV-2. This study recommends more research into both occupant and building-related indicators as well as cross-modal effects between various IEQ factors for developing future standards on sports facilities.