Koen Jorissen

Mr. Koen Jorissen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
DBDouwe Sietse de Bruijn
Douwe Sietse de Bruijn
KJKoen Jorissen
Koen Jorissen
WOWouter Olthuis
Wouter Olthuis
Albert van den BergAlbert van den Berg
Albert van den Berg
Microfluidic impedance flow cytometers enable high-throughput, non-invasive, and label-free detection of single-cells. Cytometers with coplanar electrodes are easy and cheap to fabricate, but are sensitive to positional differences of passing particles, owing to the inhomogeneous electric field. We present a novel particle height compensation method, which employs the dependence of measured electrical opacity on particle height. The measured electrical opacity correlates with the particle height as a result of the constant electrical double layer series capacitance of the electrodes. As an alternative to existing compensation methods, we use only two coplanar electrodes and multi-frequency analysis to determine the particle size of a mixture of 5, 6, and 7 µm polystyrene beads with an accuracy (CV) of 5.8%, 4.0%, and 2.9%, respectively. Additionally, we can predict the bead height with an accuracy of 1.5 µm (8% of channel height) using the measured opacity and we demonstrate its application in flow cytometry with yeast. The use of only two electrodes is of special interest for simplified, easy-to-use chips with a minimum amount of instrumentation and of limited size.

2 August 2024 in Measurement Science and Technology
Verified
Journal Article
Open access
KJKoen Jorissen
Koen Jorissen
LVL B Veldscholte
L B Veldscholte
MOMathieu Odijk
Mathieu Odijk
SBSissi de Beer
Sissi de Beer
We present the study of millisecond-resolved polymer brush swelling dynamics using infrared spectroscopy with a home-built quantum cascade laser-based infrared spectrometer at a 1 kHz sampling rate after averaging. By cycling the humidity of the environment of the polymer brush, we are able to measure the swelling dynamics sequentially at different wavenumbers. The high sampling rate provides us with information on the reconformation of the brush at a higher temporal resolution than previously reported. Using spectroscopic ellipsometry, we study the brush swelling dynamics as a reference experiment and to correct artefacts of the infrared measurement approach. This technique informs on the changes in the brush thickness and refractive index. Our results indicate that the swelling dynamics of the polymer brush are poorly described by Fickian diffusion, pointing toward more complicated underlying transport.

16 April 2024 in arXiv
Verified
Preprint
Open access
PDF file
KJKoen Jorissen
Koen Jorissen
LVLars B. Veldscholte
Lars B. Veldscholte
MOMathieu Odijk
Mathieu Odijk
SBSissi de Beer
Sissi de Beer
We present the study of millisecond-resolved polymer brush swelling dynamics using infrared spectroscopy with a custom-built quantum cascade laser-based infrared spectrometer at a 1 kHz sampling rate after averaging. By cycling the humidity of the environment of the polymer brush, we are able to measure the swelling dynamics sequentially at different wavenumbers. The high sampling rate provides us with information on the reconformation of the brush at a higher temporal resolution than previously reported. Using spectroscopic ellipsometry, we study the brush swelling dynamics as a reference experiment and to correct artefacts of the infrared measurement approach. This technique informs on the changes in the brush thickness and refractive index. Our results indicate that the swelling dynamics of the polymer brush are poorly described by Fickian diffusion and the Berens-Hopfenberg formalism, pointing toward more complicated underlying transport.