Erik Nilsson

Mr. Erik Nilsson

Université du Québec à Chicoutimi (UQAC)
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Building and Environment
Verified
Journal Article
Open access
ENErik Nilsson
Erik Nilsson
SMSylvain Ménard
Sylvain Ménard
DBDelphine Bard
Delphine Bard
KHKlas Hagberg
Klas Hagberg

19 December 2012 in Scandinavian Journal of Gastroenterology
Verified
Journal Article
Closed access
BSBirger Sandzén
Birger Sandzén
MHMarkku M. Haapamäki
Markku M. Haapamäki
ENErik Nilsson
Erik Nilsson
HSHans Stenlund
Hans Stenlund
MÖMikael Öman
Mikael Öman
Objective. Since early 1970s, prospective randomized controlled trials have emphasized the advantages of early cholecystectomy in patients with acute cholecystitis, compared to elective delayed cholecystectomy. The aim of this investigation was to study surgery for acute gallbladder disease in Sweden during a 15-year period when open cholecystectomy was replaced by a laparoscopic procedure. Material and methods. Data from the Swedish National Patient Register and the Cause of Death Register 1988–2006 comprising hospital stays with a primary diagnosis of gallbladder/gallstone disease in Sweden were retrieved. Patients were analyzed with reference to timing of cholecystectomy, length of hospital stay, and mortality. Results. Emergency cholecystectomy at index (first) admission or at readmission within 2 years of index admission was performed in 32.2% and 6.1% of patients, respectively. Elective cholecystectomy within 2 years of index admission was performed in 20.3% patients, whereas 41.3% of all patients did not undergo cholecystectomy within 2 years. Standardized mortality ratio did not significantly change during the audit period. Total hospital stay (days at index stay and subsequent stay(s) for biliary diagnoses within 2 years) was shorter for patients who had emergency cholecystectomy at first admission compared to patients with later or no cholecystectomy within 2 years. Conclusions. Around 30% of patients with acute gallbladder disease were operated with cholecystectomy during the first admission with no time trend from 1990 through 2004. A total of 40% of patients with acute gallbladder disease were not cholecystectomized within 2 years. Analysis of outcome of long-term conservative treatment is warranted.

12 November 2021 in Acoustics
Verified
Journal Article
Open access
PDF file
ENErik Nilsson
Erik Nilsson
NVNikolaos-Georgios Vardaxis
Nikolaos-Georgios Vardaxis
SMSylvain Menard
Sylvain Menard
DBDelphine Bard
Delphine Bard
Ventilation ducts can have a negative effect on the sound reduction index between two rooms if they pass through the dividing structure without treatments. The overall sound reduction of a ventilation duct is dependent on several factors including the transmission loss when sound is breaking in and out from the duct. This study aims to model the sound reduction of a combined system with a separating wall and a ventilation duct through it. Three walls, characterized according to ISO 717-1, are combined with three different ventilation ducts, two circular and one rectangular with different dimensions. Laboratory measurement data are used to determine the sound reduction of the different configurations and the type of treatments needed for each configuration. A proposed model with existing theory for describing sound transmission losses of circular and rectangular ventilation ducts predicts the shape of the measurement data for many frequency bands. A new theory part is developed through an iterative process for circular ducts, which is based on measurements with previous methods and studies as a guide because the existing prediction scheme is somewhat perplexing. For rectangular ducts, the existing theory has been updated to better match measurement data. The application of the proposed theory and model in this article shows similar results when compared to measurements. The difference in weighted sound reduction index between developed theories and measurement data is 0–1 dB for every configuration.

18 March 2022 in Acoustics
Verified
Journal Article
Open access
PDF file
ENErik Nilsson
Erik Nilsson
SMSylvain Menard
Sylvain Menard
DBDelphine Bard
Delphine Bard
NVNikolaos-Georgios Vardaxis
Nikolaos-Georgios Vardaxis
Sound reduction is complex to estimate for acoustical treatments on ventilation ducts through walls. Various acoustical treatments are available for ventilation ducts, including internal lining (absorption along the inner perimeter), external lagging (external sound insulation), silencer, and suspended ceilings. Previous studies have examined how silencers and the internal lining affect the sound transmission of ventilation ducts. However, there are few theories to predict the effect of external lagging in combination with ventilation ducts and how the total sound reduction is affected. This article aims to investigate different acoustical treatments and develop theoretical models when external lagging with stone wool is used to reduce flanking sound transmission via the surface area of ventilation ducts. Theoretical models are developed for external lagging and compared with measurement data. Measurements and theory are generally in good agreement over the third-octave band range of 100–5000 Hz. The developed models clarify that the distance closest to the wall has the main impact on sound reduction for a combined system with a wall and a ventilation duct. Suspended ceilings and silencers are found to be enough as acoustical treatments for certain combinations of ventilation ducts and walls. However, external lagging seems to be the only effective solution in offices and schools when a large ventilation duct passes through a wall with high sound reduction.

25 November 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ENErik Nilsson
Erik Nilsson
SMSylvain Menard
Sylvain Menard
DBDelphine Bard
Delphine Bard
KHKlas Hagberg
Klas Hagberg
High-rise wooden buildings are increasing in popularity, and they typically include cross-laminated timber in the structure. Taller buildings result in higher loads on the junctions lower down in the building, which are suggested in the literature to negatively affect the sound insulation. This study involved measurement of the vibration reduction index in four different CLT buildings, varying in height and junction details. A total of 12 junctions were measured at both high and low levels in the buildings. Among these, 10 junctions had resilient interlayers with different stiffnesses dependent on the designed quasi-permanent load, while 2 junctions lacked resilient interlayers. The results indicated that the vibration reduction index decreases lower down in the building mainly for the Wall–Wall path. The findings were consistent for all measured junctions above 400 Hz for the Wall–Wall path and for the majority of the measurements of the remaining frequency range, 400 Hz and below. The observed difference in the vibration reduction index could significantly impact the final result if a high-rise building has several flanking paths that affect the sound insulation between two apartments, and this needs to be considered during the design phase. Similar effects were shown for buildings both with and without resilient interlayers in the junctions.

1 November 2000 in Journal of Clinical Epidemiology
Verified
Journal Article
Closed access
PDF file
PBPaul Blomqvist
Paul Blomqvist
HLHåkan Ljung
Håkan Ljung
ENErik Nilsson
Erik Nilsson
AEAnders Ekbom
Anders Ekbom