To compare corneal thickness measurements using Orbscan II (OII) and ultrasonic (US) pachymetry in normal and in keratoconic eyes. Eye Department, Heartlands and Solihull NHS Trust, Birmingham, United Kingdom. Central corneal thickness (CCT) was measured by means of OII and US pachymetry in 1 eye of 72 normal subjects and 36 keratoconus patients. The apical corneal thickness (ACT) in keratoconus patients was also evaluated using each method. The mean of the difference, standard deviation (SD), and 95% limits of agreement (LoA = mean +/- 2 SD), with and without applying the default linear correction factor (LCF), were determined for each sample. The Student t test was used to identify significant differences between methods, and the correlation between methods was determined using the Pearson bivariate correlation. Bland-Altman analysis was performed to confirm that the results of the 2 instruments were clinically comparable. In normal eyes, the mean difference (+/- 95% LoA) in CCT was 1.04 microm +/- 68.52 (SD) (P>.05; r = 0.71) when the LCF was used and 46.73 +/- 75.40 microm (P =.0001; r = 0.71) without the LCF. In keratoconus patients, the mean difference (+/- 95% LoA) in CCT between methods was 42.46 +/- 66.56 microm (P<.0001: r = 0.85) with the LCF, and 2.51 +/- 73.00 microm (P>.05: r = 0.85) without the LCF. The mean difference (+/- 95% LoA) in ACT for this group was 49.24 +/- 60.88 microm (P<.0001: r = 0.89) with the LCF and 12.71 +/- 68.14 microm (P =.0077; r = 0.89) when the LCF was not used. This study suggests that OII and US pachymetry provide similar readings for CCT in normal subjects when an LCF is used. In keratoconus patients, OII provides a valid clinical tool for the noninvasive assessment of CCT when the LCF is not applied.
1 December 2003 in British Journal of Ophthalmology
Aims: To determine the visual outcome following initiation of brimonidine therapy in glaucoma. Methods: 16 newly diagnosed previously untreated glaucoma patients were randomly assigned to either timolol 0.5% or brimonidine 0.2%. Visual acuity, contrast sensitivity (CS), visual fields, intraocular pressure (IOP), blood pressure, and heart rate were evaluated at baseline and after 3 months. Results: IOP reduction was similar for both groups (p<0.05). Brimonidine improved CS; in the right eye at 6 and 12 cpd (p = 0.043, p = 0.017); in the left eye at 3 and 12 cpd (p = 0.044, p = 0.046). Timolol reduced CS at 18 cpd in the right eye (p = 0.041). There was no change in any other measured parameters. Conclusion: Glaucoma patients exhibit improved CS on initiation of brimonidine therapy.
1 May 2013 in Investigative Ophthalmology & Visual Science
Purpose.: To investigate in parallel the systemic glutathione levels of patients suffering from primary open angle glaucoma (POAG) or normal tension glaucoma (NTG) with comparable functional loss. Methods.: Thirty-four POAG patients, 30 NTG patients, and 53 controls were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. Systemic blood pressure (BP) and ocular perfusion pressure (OPP) parameters were also determined. Results.: Independent of age, POAG and NTG patients demonstrated significantly lower GSH and t-GSH levels than age-matched controls (P < 0.001). Additionally, a lower redox index was found, but in POAG patients only, in comparison to both NTG and control groups (P = 0.020). GSSG levels were, however, similar between all study groups (P > 0.05). Conclusions.: This study demonstrates, for the first time, that both POAG and NTG patients exhibit lower GSH and t-GSH levels than age-matched controls, indicating a similar general compromise of the antioxidant defense systems may exist in both conditions.