Quinoline-based two new ligands have been synthesized (QL1 and QL2) by reacting 8-quinoline carboxylic acid with derivatives of L-valine under a condensation reaction. The synthesized ligands were characterized by spectroscopic techniques such as 1H NMR, UV, IR, HRMS and CHNS. The 3D structures of both ligands were optimized for the lowest energy and the HOMO-LUMO orbitals were developed. The photoluminescence analysis of both ligands showed the fluorescence emission wavelengths on 492 and 508 nm, respectively for QL1 and QL2. The substituents on the quinoline ring influence the change in fluorescence emission wavelengths. Synthesized ligands acted as selective fluorescence turn-off chemosensors for Cu2+ ions and demonstrated the sensitive detection of Cu2+ ions in different water samples at the nanomolar scale. The interaction between metal ion and ligands were also studied by developing DFT structures.
13 August 2022 in Journal of the Indian Chemical Society
An efficient turn-off-fluorescence chemosensing method has been developed to detect Cu2+ ions in a variety of samples. Two new quinoline-based chemosensors (QC1 and QC2) have been prepared under the condensation reaction of 8-quinolinecarboxylic acid with derivatives of L-valine. The synthesized chemosensors were characterized by spectroscopic techniques such as 1H NMR, UV, IR, HRMS and CHNS. The HOMO-LUMO orbitals and energy-minimized structures of the chemosensors were developed. The interaction of metal ions with chemosensors and stable structures of complexes were investigated using DFT. The photoluminescence analysis of both chemosensors (QC1 and QC2) showed the fluorescence emission wavelengths on 495 and 512 nm, respectively, for QC1 and QC2. The change in fluorescence emission wavelengths depends on the electronic effects of the substituents on the quinoline ring. The chemosensors showed a high sensitivity for Cu ions; thus, the detection was exhibited in nanomolar levels. The chemosensing studies were performed in the presence of different metal ions and samples taken from other sources.
Environmental pollution crisis, particularly mercury ions (Hg2+) contamination, seriously threatens the health of all living organisms. Many studies have shown that even extremely low concentrations of Hg2+ can rigorously damage living organisms. Therefore, it is very much needed for real-time detection of Hg2+. To tackle mercury contamination and for its detection, we herewith proposed an intelligent design of a new fluorescent ‘turn-on’ probe, which was prepared based on the mercury-promoted hydrolysis of vinyl ether moiety. The probe rapidly reacted with mercury ions and showed good selectivity over other metal ions.