Falcondes José Mendes de Seixas

Prof. Dr. Falcondes José Mendes de Seixas

electrical engineering, UNESP, Ilha Solteira, São Paulo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JBJuan Paulo Robles Balestero
Juan Paulo Robles Balestero
FTFernando Lessa Tofoli
Fernando Lessa Tofoli
RFRodolfo Castanho Fernandes
Rodolfo Castanho Fernandes
GTGrover Victor Torrico-Bascope
Grover Victor Torrico-Bascope
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
The need for solid-state ac-dc converters to improve power quality in terms of power factor correction, reduced total harmonic distortion at input ac mains, and precisely regulated dc output has motivated the investigation of several topologies based on classical converters such as buck, boost, and buck-boost converters. Boost converters operating in continuous-conduction mode have become particularly popular because reduced electromagnetic interference levels result from their utilization. Within this context, this paper introduces a bridgeless boost converter based on a three-state switching cell (3SSC), whose distinct advantages are reduced conduction losses with the use of magnetic elements with minimized size, weight, and volume. The approach also employs the principle of interleaved converters, as it can be extended to a generic number of legs per winding of the autotransformers and high power levels. A literature review of boost converters based on the 3SSC is initially presented so that key aspects are identified. The theoretical analysis of the proposed converter is then developed, while a comparison with a conventional boost converter is also performed. An experimental prototype rated at 1 kW is implemented to validate the proposal, as relevant issues regarding the novel converter are discussed.

30 December 2002
Verified
Conference Paper
Closed access
DMD.C. Martins
D.C. Martins
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
JBJ.A. Brilhante
J.A. Brilhante
IBI. Barbi
I. Barbi
A commutation cell is proposed that is destined to replace the conventional hard switched one in PWM DC-DC converters, with the following advantages: commutation at zero-voltage for both the active and the passive semiconductor, PWM at constant frequency, no overvoltage across the switches, and no additional current stress in comparison to the hard switching converter counterpart. Auxiliary components rated at very small current are used. Both the main and the auxiliary switches are gated by the same signal, rendering simple the drive circuitry. The principle of operation and analysis are provided. Experimental results obtained from a prototype rated at 300 V and 1.2 kW are also presented.

1 July 2011 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RFRodolfo Castanho Fernandes
Rodolfo Castanho Fernandes
POPriscila da Silva Oliveira
Priscila da Silva Oliveira
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
Multipulse rectifier topologies based on autoconnections are increasingly applied as interface stages between mains and power electronics converters. These topologies are attractive and cost-effective solutions for meeting the requirements of low total harmonic distortion of line current and high power factor. Furthermore, as only a small fraction of the total power required by the load is processed in the magnetic core, the overall resulting volume and weight are reduced. This paper proposes a mathematical analysis based on phasor diagrams that results in a single and general expression capable of unifying all delta and wye step-up or step-down autotransformer connections for 12- and 18-pulse ac-dc converters. The expression obtained allows the choice of a wide range of input/output voltage ratio for step-up or step-down autotransformer, and this general expression is also presented in a graphical form for each converter. Moreover, it simplifies the procedure for determining turn ratios and polarities for all windings of the autotransformer. A routine for easy and fast calculations is developed and validated by a design example. Finally, experimental results are presented along with comments on a 6-kW 220-V line voltage, 400-V rectified voltage, and 18-pulse delta-autoconnected prototype.

2 May 2012 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JBJuan Paulo Robles Balestero
Juan Paulo Robles Balestero
FTFernando Lessa Tofoli
Fernando Lessa Tofoli
GTGrover Victor Torrico-Bascopé
Grover Victor Torrico-Bascopé
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
This paper presents a pulsewidth modulation dc-dc nonisolated buck converter using the three-state switching cell, constituted by two active switches, two diodes, and two coupled inductors. Only part of the load power is processed by the active switches, reducing the peak current through the switches to half of the load current, as higher power levels can then be achieved by the proposed topology. The volume of reactive elements, i.e., inductors and capacitors, is also decreased since the ripple frequency of the output voltage is twice the switching frequency. Due to the intrinsic characteristics of the topology, total losses are distributed among all semiconductors. Another advantage of this converter is the reduced region for discontinuous conduction mode when compared to the conventional buck converter or, in other words, the operation range in continuous conduction mode is increased, as demonstrated by the static gain plot. The theoretical approach is detailed through qualitative and quantitative analyses by the application of the three-state switching cell to the buck converter operating in nonoverlapping mode (D <; 0.5). Besides, the mathematical analysis and development of an experimental prototype rated at 1 kW are carried out. The main experimental results are presented and adequately discussed to clearly identify its claimed advantages.

1 July 1997 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
DMD.C. Martins
D.C. Martins

1 September 2011
Verified
Conference Paper
Closed access
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
MBMoacyr A. G. de Brito
Moacyr A. G. de Brito
This paper proposes a bridgeless boost interleaved PFC (power factor correction) converter with variable duty cycle control. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of converters cells allows division of efforts in semiconductor devices and reduction of weight and volume of the input EMI filter. The use of variable duty cycle control has the functions of regulating the output voltage and eliminating the low order harmonic components that appears in the input current of the common interleaved power factor converters working in Discontinuous Conduction Mode (DCM). The simulation results of the proposed converter presented high power factor and a good transient response in relation to the output voltage regulation in presence of high load variations and supply voltage variations.