Luciano de Souza da Costa e Silva

Dr. Luciano de Souza da Costa e Silva

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011
Verified
Conference Paper
Closed access
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
MBMoacyr A. G. de Brito
Moacyr A. G. de Brito
This paper proposes a bridgeless boost interleaved PFC (power factor correction) converter with variable duty cycle control. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of converters cells allows division of efforts in semiconductor devices and reduction of weight and volume of the input EMI filter. The use of variable duty cycle control has the functions of regulating the output voltage and eliminating the low order harmonic components that appears in the input current of the common interleaved power factor converters working in Discontinuous Conduction Mode (DCM). The simulation results of the proposed converter presented high power factor and a good transient response in relation to the output voltage regulation in presence of high load variations and supply voltage variations.

1 November 2012
Verified
Conference Paper
Closed access
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
POPriscila da S. Oliveira
Priscila da S. Oliveira
This paper presents theoretical evaluation and experimental results to the proposed bridgeless interleaved boost PFC (power factor correction) converter. The application of bridgeless technique causes reduction of conduction losses, while the interleaving technique of the converter cells allows division of the current stress in semiconductor devices and reduction of weight and volume of the input EMI filter. In each cell of the converter, the inductor current operates in discontinuous conduction mode (DCM), which eliminates turn-on switching losses and the effects of reverse recovery in semiconductors, increasing the efficiency of the converter. The experimental results show the power factor of 0.96 for employed voltage ratio and an efficiency of 95.2 % for nominal load conditions.

1 November 2012
Verified
Conference Paper
Closed access
POP. S. Oliveira
P. S. Oliveira
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
Multipulse rectifiers can replace a conventional six pulse three-phase rectifier (diode bridge) providing a DC voltage with low ripple, low Total Harmonic Distortion of current (THDi) and a high Power Factor (PF). In this context is presented a multipulse rectifier with generalized Delta-differential autotransformer topology, which can provide any level of DC output voltage for any level of three-phase AC input voltage. This paper presents all the possible configurations for Delta topology in order to choose, through graphics, one configuration that presents reduced weight and volume. The average voltage on the DC bus must be compatible with the DC voltage in the six pulse rectifier used in commercial ASDs. Therefore, it is possible to apply the retrofit technique to replace the conventional bridge rectifier by the proposed multipulse rectifier. Based on mathematic models and simulation results, an 18-pulse rectifier with Delta topology, 220 V of line voltage, 315 V of DC output, and rating 2.5 kW of power was designed, implemented and applied for three different commercial ASDs. Experimental results as voltage and current waveforms and results about PF and THDi will be presented.

1 November 2015
Verified
Conference Paper
Closed access
JPJoao Carlos Pelicer
Joao Carlos Pelicer
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
ALAngelo Cesar de Lourenco
Angelo Cesar de Lourenco
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
Since the AC-DC conversion is widely spread in power sources, this work proposes a novel strategy of multi-pulse topologies, associated to the half-controlled boost-based rectifier, which has the follows main advantages: low Total Harmonic Distortion of the line current (THDi), below 2%; Power Factor (PF) close to unit; simple gate drive circuit, since all active switches are connected to the same reference; robustness given that the DCM operation results the peaks of the current naturally follow the voltage waveform. The control circuit becomes very simplified because all the switches are synchronized and only one basic voltage loop should be used to regulate the DC output, without current sensors. In addition, the commutation process occurs after the current in the diode becomes zero (DCM), without losses and current stresses due to the diode reverse recovery. The simulation analysis shows a significant improvement of PF once the THDi is lower than 2% while the conventional 12-pulse topologies have about 14%. Each conventional three-phase bridge rectifier is replaced by a three-phase half-controlled boost-based topology, also called of bridgeless rectifiers. A 2.5 kW prototype is being built and its feature is a strong candidate for More Electric Aircraft (MEA) and Adjustable Speed Drive (ASD) applications.

1 November 2018
Verified
Conference Paper
Closed access
DMDouglas C. Morais
Douglas C. Morais
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
LSLucas C. Souza
Lucas C. Souza
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
JJJoão C. P. Júnior
João C. P. Júnior
Converters operating in discontinuous-conduction-mode and using the bridgeless technique can offer rectification and elevation of voltage in high frequency, also can offer better efficiency when compared to the conventional single-switch boost power-factor-correction converter. In this conduction mode, the input current naturally follows a sinusoidal envelope, dispensing current sensors of use. Some these advantages are inherent to the converter operating mode, as the zero-current-switching during the turn-on of the switches, the simplicity of control system and the lower cost. However, the discontinuous-conduction-mode operation with constant duty cycle control leads to a high harmonic content of current in low frequency, limiting the converters applications and may exceed the limits imposed by international standards. This paper presents the analysis and experimental results of the three-phase bridgeless boost converter with new variable duty cycle control, operating in discontinuous-conduction-mode. In this configuration, the current stress in semiconductors are divided and, a single pulse is necessary for switch conduction. The results proved that occurs power factor correction with harmonic current content reduction of input current in low frequency.

19 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
LSLucas Carvalho Souza
Lucas Carvalho Souza
LSLuciano de Souza da Costa e Silva
Luciano de Souza da Costa e Silva
FSFalcondes José Mendes de Seixas
Falcondes José Mendes de Seixas
LALuis De Oro Arenas
Luis De Oro Arenas
This paper proposes two non-isolated step-down DC–DC converters based on the type-A three-state switching cell (3SSC-A), resulting in an alternative to the buck and buck-boost classical converters, respectively. The proposed topologies are part of a group of unexplored converters that employ the 3SSC-A, which has the advantages of 3SSC-based converters, such as high power density, reduced current stress on the semiconductors and suitable thermal loss distribution. In this regard, a complete static analysis is performed, including a detailed study of all semiconductor voltage and current efforts and developing loss models for each one. Moreover, by using simulation models, AC sweep analyses validate the dynamic frequency response of each converter’s small-signal models, and PI-based output–voltage closed-loop controllers are duly designed. Finally, the topologies are experimentally validated through the implementation of adequately designed prototypes, achieving efficiency values greater than 91% under several output power rates varying from 50% to 100%.