A theoretical-experimental research has been carried out to determine the characteristics of a radio frequency (RF) ion source for the generation of a weakly expanding wedge-shaped xenon ion beam. Such ion beam geometry is of interest as a prototype of an on-board ion injector for contactless “ion shepherding” by service spacecraft to remove large space debris objects from geostationary orbits. The wedge shape of the ion beam increases its range. The device described herein comprises an inductive gas discharge chamber and a slit-type three-electrode ion extraction grid (IEG) unit. Calculations of accelerating cell geometries and ion trajectories determined the dependence of beam expansion half-angle on normalized perveance based on the measurements of the spatial distributions of the xenon plasma parameters at the IEG entrance for a xenon flow rate q ≈ 0.2 mg/s and an incident RF power Pin ≤ 250 W at a driving frequency f = 2 MHz. Experimental studies showed that the ion beam, circular at the IEG exit, accepted the elliptical form at the distance of 580 mm with half-angle of beam expansion across IEG slits about 2°–3° and close to 0° along them. Thus, the obtained result proved the possibility of creating a new-generation on-board ion injector that could be used in spacecrafts for removal of debris.
1 November 2013 in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
The cell of a multiaperture three-electrode ion-extraction system (IES) with a plasma ion emitter is numerically simulated within the range of ion current density and accelerating potentials corresponding to gas-discharge ion sources used in technological and space applications (ion thrusters). The formation of the primary ion beam and the configuration of the secondary (charge-exchange) ion flux impinging on the IES electrodes from both the beam volume and the beam-transport (neutralization) region are investigated for different IES geometries. The erosion of the accelerating electrode is estimated.
At present, the requirements for the lifetime of electric propulsion thrusters of spacecraft are growing. The article is devoted to the selection of material of the accelerating electrode that is the...
6 October 2018 in Journal of Contemporary Psychotherapy
To develop elements of a system for contact-free transportation of objects in space has now become an urgent task for the contemporary space-related activities. The purpose of work that is presented hereinafter was to conduct ground tests of the ion source, which is a key element of the above-mentioned system, and to compare the obtained experimental data with the mathematical simulation results in order to build a refined physical and mathematical model of the ion source. Such model was built on the basis of the classical problem regarding the motion of charged particles in an electrostatic field. Parameters of the ion source have been determined experimentally for several operating modes using various structural designs of the ion source electrodes. Two types of ion optics were tested—with slit and round apertures. Good correlation between simulation results and experimental data has been demonstrated. The optimum ion source operation modes have been identified to ensure minimum divergence angles for the plasma beam exiting from the ion source, which in its turn maximizes the pulse transmitted to the transported object.
Currently, in patients with systemic lupus erythematosus (SLE) increasing attention is paid to the ovarian reserve evaluation, which can serve as one of the markers of a favorable response to therapy and pregnancy planning. For this purpose, anti-Mullerian hormone (AMH) is considered as the most sensitive marker, that reflect the continuous growth of small follicles. The article presents data on the relationship of serum hormone levels with age, ethnicity, body weight, disease activity, and therapy. We present clinical cases of three women of childbearing age with SLE, different duration of the disease and cumulative dose of disease-modifying antirheumatic drugs in whom the level of AMH in the blood serum was measured.