Transient simulation model of doubly‐fed induction generator‐based wind turbine has a complex model structure and considerable control parameters. An accurate simulation model is especially important for studying the static and transient characteristics of doubly‐fed induction generator‐based wind turbine and the grid‐connected system. Based on the measured data of low voltage ride‐through testing, the integrated parameter identification method is proposed here. Combined with the time‐domain simulation analysis, curve fitting is used to determine the control strategy of doubly‐fed induction generator‐based wind turbine. The improved genetic algorithm is used to identify the generator parameters, power control parameters, and resistance of Crowbar of doubly‐fed induction generator‐based wind turbine. Combined with the electrical parameters provided by the wind turbine manufacturer, electromagnetic transient model on full operation condition and rapid starting period, corresponding to a measured doubly‐fed induction generator‐based wind turbine in West Inner Mongolia Power Grid, is then established, which can operate in the full wind speed range and quickly enter the stable state within 1 s after start‐up. Comparison of simulation results and measured data shows that the established electromagnetic transient simulation model using parameters identified by the proposed method can accurately reflect the key characteristics of doubly‐fed induction generator‐based wind turbine.
With the continuous increase in wind power penetration, doubly fed wind turbines can quickly respond to changes in grid frequency, and have particularly important inertia-response characteristics. This article starts with the excitation control principle of a doubly fed induction generator, compares the transient frequency characteristics of the synchronous generator under fault, and proposes that the doubly fed induction generator can control the speed or active power of the generator through excitation. It proves the unique “active power transient frequency characteristics” of doubly fed induction generators. Under different wind speeds, the inertia response capability of the wind turbine is quantified, and the degrees of influence of the inertia time constant and frequency characteristic slope of the doubly fed induction generator on the transient change process are analyzed. Finally, simulation and experiments verify the correctness of the above theory, which provides a basis for significantly improving the transient stability of the power system and realizing the controllability of the transient stability of the power system.