Arin Marchesi

Prof. Arin Marchesi

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
RARomain Amyot
Romain Amyot
AMArin Marchesi
Arin Marchesi
CFClemens M. Franz
Clemens M. Franz
ICIgnacio Casuso
Ignacio Casuso
HFHolger Flechsig
Holger Flechsig
Atomic force microscopy (AFM) can visualize the dynamics of single biomolecules under near-physiological conditions. However, the scanning tip probes only the molecular surface with limited resolution, missing details required to fully deduce functional mechanisms from imaging alone. To overcome such drawbacks, we developed a computational framework to reconstruct 3D atomistic structures from AFM surface scans, employing simulation AFM and automatized fitting to experimental images. We provide applications to AFM images ranging from single molecular machines, protein filaments, to large-scale assemblies of 2D protein lattices, and demonstrate how the obtained full atomistic information advances the molecular understanding beyond the original topographic AFM image. We show that simulation AFM further allows for quantitative molecular feature assignment within measured AFM topographies. Implementation of the developed methods into the versatile interactive interface of the BioAFMviewer software, freely available at www.bioafmviewer.com, presents the opportunity for the broad Bio-AFM community to employ the enormous amount of existing structural and modeling data to facilitate the interpretation of resolution-limited AFM images.

28 September 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
AMArin Marchesi
Arin Marchesi
XGXiaolong Gao
Xiaolong Gao
RARicardo Adaixo
Ricardo Adaixo
JRJan Rheinberger
Jan Rheinberger
HSHenning Stahlberg
Henning Stahlberg
SSSimon Scheuring
Simon Scheuring
Cyclic nucleotide-gated (CNG) ion channels are non-selective cation channels key to signal transduction. The free energy difference of cyclic-nucleotide (cAMP/cGMP) binding/unbinding is translated into mechanical work to modulate the open/closed probability of the pore, i.e., gating. Despite the recent advances in structural determination of CNG channels, the conformational changes associated with gating remain unknown. Here we examine the conformational dynamics of a prokaryotic homolog of CNG channels, SthK, using high-speed atomic force microscopy (HS-AFM). HS-AFM of SthK in lipid bilayers shows that the CNBDs undergo dramatic conformational changes during the interconversion between the resting (apo and cGMP) and the activated (cAMP) states: the CNBDs approach the membrane and splay away from the 4-fold channel axis accompanied by a clockwise rotation with respect to the pore domain. We propose that these movements may be converted by the C-linker to pull the pore helices open in an iris diaphragm-like mechanism.

21 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AMArin Marchesi
Arin Marchesi
KUKenichi Umeda
Kenichi Umeda
TKTakumi Komekawa
Takumi Komekawa
TMTakeru Matsubara
Takeru Matsubara
HFHolger Flechsig
Holger Flechsig
CFClemens M. Franz
Clemens M. Franz
High-speed atomic force microscopy (HS-AFM) is a powerful tool for visualizing the dynamics of individual biomolecules. However, in single-molecule HS-AFM imaging applications, x,y-scanner ranges are typically restricted to a few hundred nanometers, preventing overview observation of larger molecular assemblies, such as 2-dimensional protein crystal growth or fibrillar aggregation. Previous advances in scanner design using mechanical amplification of the piezo-driven x,y-positioning system have extended the size of HS-AFM image frames to several tens of micrometer, but these large scanners may suffer from mechanical instabilities at high scan speeds and only record images with limited pixel numbers and comparatively low lateral resolutions (> 20–100 nm/pixel), complicating single-molecule analysis. Thus, AFM systems able to image large sample areas at high speeds and with nanometer resolution have still been missing. Here, we describe a HS-AFM sample-scanner system able to record large topographic images (≤ 36 × 36 µm2) containing up to 16 megapixels, providing molecular resolution throughout the image frame. Despite its large size, the flexure-based scanner features a high resonance frequency (> 2 kHz) and delivers stable operation even at high scans speeds of up to 7.2 mm/s, minimizing the time required for recording megapixel scans. We furthermore demonstrate that operating this high-speed scanner in time-lapse mode can simultaneously identify areas of spontaneous 2-dimensional Annexin A5 crystal growth, resolve the angular orientation of large crystalline domains, and even detect rare crystal lattice defects, all without changing scan frame size or resolution. Dynamic processes first identified from overview scans can then be further imaged at increased frame rates in reduced scan areas after switching to conventional HS-AFM scanning. The added ability to collect large-area, high-resolution images of complex samples within biological-relevant time frames extends the capabilities of HS-AFM from single-molecule imaging to the study of large dynamic molecular arrays. Moreover, large-area HS-AFM scanning can generate detailed structural data sets from a single scan, aiding the quantitative analysis of structurally heterogenous samples, including cellular surfaces.

4 September 2018 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
YRYi Ruan
Yi Ruan
KKKevin Kao
Kevin Kao
SLSolène Lefebvre
Solène Lefebvre
AMArin Marchesi
Arin Marchesi
PCPierre-Jean Corringer
Pierre-Jean Corringer
SSSimon Scheuring
Simon Scheuring
Significance: Gloeobacter violaceus ligand-gated ion channel (GLIC) is a proton-gated, cation-selective channel, a Cys-loop family member of the pentameric ligand-gated ion channels (pLGICs). In a pursuit to provide evidence of function-related conformational changes of a pLGIC in membrane, at ambient temperature and pressure and of the very same unlabeled molecules, we used high-speed atomic force microscopy (HS-AFM) combined with a buffer exchange system to visualize reversible changes of the supramolecular arrangement and conformations of GLIC during pH changes: a structural titration experiment. Reference-free classification of the molecules assigns conformations to states during the pH titration. We find large conformational changes with an unexpected closed-state structure with tightened extracellular domains. Furthermore, we provide evidence for the short-term existence of asymmetric channels at early stages of activation.

6 August 2021 in Pflügers Archiv - European Journal of Physiology
Verified
Journal Article
Closed access
PDF file
LNLuisa Maria Rosaria Napolitano
Luisa Maria Rosaria Napolitano
VTVincent Torre
Vincent Torre
AMArin Marchesi
Arin Marchesi

22 June 2015 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
LNLuisa Maria Rosaria Napolitano
Luisa Maria Rosaria Napolitano
IBIna Bisha
Ina Bisha
MMMatteo De March
Matteo De March
AMArin Marchesi
Arin Marchesi
MAManuel Arcangeletti
Manuel Arcangeletti
VTVincent Torre
Vincent Torre
Significance: Cyclic nucleotide-gated (CNG) channels underlie sensory transduction in photoreceptors and olfactory epithelium and share a high degree of homology with K + channels. However, these channels conduct Na + and K + differently: although K + channels discriminate with high accuracy Na + from K + , CNG channels do not discriminate among different cations. By combining electrophysiology, molecular dynamics simulations, and X-ray crystallography we found that the pore region exhibits a dynamic structure. We show that ( i ) the selectivity filter can adapt to large and small ions with a different geometry and ( ii ) the pore diameter critically depends on the ion within. We conclude that the pore of CNG channels is highly flexible and that this flexibility is at the basis of their poor ionic selectivity.