Laurent Roten

Prof. Dr. Laurent Roten

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2012 in Circulation
Verified
Journal Article
Closed access
PJPierre Jaïs
Pierre Jaïs
PMPhilippe Maury
Philippe Maury
PKPaul Khairy
Paul Khairy
FSFrédéric Sacher
Frédéric Sacher
INIsabelle Nault
Isabelle Nault
MHMichel Haïssaguerre
Michel Haïssaguerre
Background—: Catheter ablation of ventricular tachycardia (VT) is effective and particularly useful in patients with frequent defibrillator interventions. Various substrate modification techniques have been described for unmappable or hemodynamically intolerable VT. Noninducibility is the most frequently used end point but is associated with significant limitations, so the optimal end point remains unclear. We hypothesized that elimination of local abnormal ventricular activities (LAVAs) during sinus rhythm or ventricular pacing would be a useful and effective end point for substrate-based VT ablation. As an adjunct to this strategy, we used a new high-density mapping catheter and frequently used epicardial mapping. Methods and Results—: Seventy patients (age, 67±11 years; 7 female) with VT and structurally abnormal ventricle(s) were prospectively enrolled. Conventional mapping was performed in sinus rhythm in all, and a high-density Pentaray mapping catheter was used in the endocardium (n=35) and epicardially. LAVAs were recorded in 67 patients (95.7%; 95% confidence interval, 89.2–98.9). Catheter ablation was performed targeting LAVA with an irrigated-tip catheter placed endocardially via a transseptal or retrograde aortic approach or epicardially via the subxiphoid approach. LAVAs were successfully abolished or dissociated in 47 of 67 patients (70.1%; 95% confidence interval, 58.7–80.1). In multivariate analysis, LAVA elimination was independently associated with a reduction in recurrent VT or death (hazard ratio, 0.49; 95% confidence interval, 0.26–0.95; P =0.035) during long-term follow-up (median, 22 months). Conclusions—: LAVAs can be identified in most patients with scar-related VT. Elimination of LAVAs is feasible and safe and is associated with superior survival free from recurrent VT.

4 July 2023 in Circulation
Verified
Journal Article
Closed access
MTMohit K. Turagam
Mohit K. Turagam
PNPetr Neuzil
Petr Neuzil
BSBoris Schmidt
Boris Schmidt
TRTobias Reichlin
Tobias Reichlin
KNKars Neven
Kars Neven
VRVivek Y. Reddy
Vivek Y. Reddy
Background: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. Methods: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (7 days) major adverse events. Results: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA 2 DS 2 -VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289–421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%–80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P =0.001). Acute major adverse events occurred in 1.9% of patients. Conclusions: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.

28 June 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
BSBoris Schmidt
Boris Schmidt
SBStefano Bordignon
Stefano Bordignon
KNKars Neven
Kars Neven
TRTobias Reichlin
Tobias Reichlin
YBYuri Blaauw
Yuri Blaauw
KCKyoung Ryul Julian Chun
Kyoung Ryul Julian Chun
Aims: Pulsed field ablation (PFA) is a new, non-thermal ablation modality for pulmonary vein (PV) isolation in patients with atrial fibrillation (AF). The multi-centre EUropean Real World Outcomes with Pulsed Field AblatiOn in Patients with Symptomatic AtRIAl Fibrillation (EU-PORIA) registry sought to determine the safety, efficacy, and learning curve characteristics for the pentaspline, multi-electrode PFA catheter. Methods and results: All-comer AF patients from seven high-volume centres were consecutively enrolled. Procedural and follow-up data were collected. Learning curve effects were analysed by operator ablation experience and primary ablation modality. In total, 1233 patients (61% male, mean age 66 ± 11years, 60% paroxysmal AF) were treated by 42 operators. In 169 patients (14%), additional lesions outside the PVs were performed, most commonly at the posterior wall (n = 127). Median procedure and fluoroscopy times were 58 (interquartile range: 40–87) and 14 (9–21) min, respectively, with no differences due to operator experience. Major complications occurred in 21/1233 procedures (1.7%) including pericardial tamponade (14; 1.1%) and transient ischaemic attack or stroke (n = 7; 0.6%), of which one was fatal. Prior cryoballoon users had less complication. At a median follow-up of 365 (323–386) days, the Kaplan–Meier estimate of arrhythmia-free survival was 74% (80% for paroxysmal and 66% for persistent AF). Freedom from arrhythmia was not influenced by operator experience. In 149 (12%) patients, a repeat procedure was performed due to AF recurrence and 418/584 (72%) PVs were durably isolated. Conclusion: The EU-PORIA registry demonstrates a high single-procedure success rate with an excellent safety profile and short procedure times in a real-world, all-comer AF patient population.

1 February 2015 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
USUniv.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
Univ.-Prof. Priv.-Doz. Dr.med.univ. Daniel Scherr
PKPaul Khairy
Paul Khairy
SMShinsuke Miyazaki
Shinsuke Miyazaki
VAValerie Aurillac-Lavignolle
Valerie Aurillac-Lavignolle
PPPatrizio Pascale
Patrizio Pascale
PJPierre Jais
Pierre Jais
Background—: This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point. Methods and Results—: One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43–73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070–7.143; P <0.001), left atrial diameter ≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078–4.016; P =0.03), continuous AF duration ≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024–3.846; P <0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037–3.388; P =0.04) predicted arrhythmia recurrence. Conclusions—: In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.

1 August 2013 in JACC
Verified
Journal Article
Closed access
AJAmir S. Jadidi
Amir S. Jadidi
HCHubert Cochet
Hubert Cochet
ASAshok J. Shah
Ashok J. Shah
SKSteven J. Kim
Steven J. Kim
EDEdward Duncan
Edward Duncan
PJPierre Jaïs
Pierre Jaïs

1 August 2011 in The American Journal of Cardiology
Verified
Journal Article
Closed access
MWMatthias Wilhelm
Matthias Wilhelm
LRLaurent Roten
Laurent Roten
HTHildegard Tanner
Hildegard Tanner
IWIlca Wilhelm
Ilca Wilhelm
JSJean-Paul Schmid
Jean-Paul Schmid
HSHugo Saner
Hugo Saner