Ville Rantanen

Dr. Ville Rantanen

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in Synthetic Metals
Verified
Journal Article
Closed access
STSampo Tuukkanen
Sampo Tuukkanen
TJTuomas Julin
Tuomas Julin
VRVille Rantanen
Ville Rantanen
MZMari Zakrzewski
Mari Zakrzewski
PMPasi Moilanen
Pasi Moilanen
SRSatu Rajala
Satu Rajala

17 December 2009 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
VRVille Rantanen
Ville Rantanen
PNPekka-Henrik Niemenlehto
Pekka-Henrik Niemenlehto
JVJarmo Verho
Jarmo Verho
JLJukka Lekkala
Jukka Lekkala

1 January 2012 in Interacting with Computers
Verified
Journal Article
Closed access
OTOuti Tuisku
Outi Tuisku
VSVeikko Surakka
Veikko Surakka
TVToni Vanhala
Toni Vanhala
VRVille Rantanen
Ville Rantanen
JLJukka Lekkala
Jukka Lekkala

1 February 2019 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
MIMirja Ilves
Mirja Ilves
JLJani Lylykangas
Jani Lylykangas
VRVille Rantanen
Ville Rantanen
EMEeva Mäkelä
Eeva Mäkelä
AVAntti Vehkaoja
Antti Vehkaoja
VSVeikko Surakka
Veikko Surakka

18 June 2013 in IEEE Sensors Journal
Verified
Journal Article
Closed access
VRVille Rantanen
Ville Rantanen
HVHanna Venesvirta
Hanna Venesvirta
OSOleg Spakov
Oleg Spakov
JVJarmo Verho
Jarmo Verho
AVAkos Vetek
Akos Vetek
JLJukka Lekkala
Jukka Lekkala
The intensity measurement of facial muscle activity can be used in several applications such as human-computer interaction and behavioral science. A new method for the intensity measurement is presented. It is based on a contactless, capacitive measurement of the movements that the facial activity produces. The muscles responsible for raising the eyebrows, lowering the eyebrows, raising the mouth corners, and pulling down the mouth corners are measured simultaneously with the capacitive method and electromyography (EMG) during controlled experiments. Each muscle is activated by 10 participants at three different intensity levels (low, medium, and high), 10 repetitions at each level. The capacitive intensity values are in good agreement with the ones registered with the EMG: average mean absolute errors are between 7% and 12% of the observed intensity range. However, compared with the EMG, the capacitive intensity values are noticed to have offsets that may be partly caused by the measurement itself and partly by the EMG reference. As a result, the measurement may require a calibration for more intensity values than just the maximum. In the capacitive method, it is also required to distinguish between the muscle activations originating from the same facial regions to determine which activation is taking place. This is done with an almost perfect performance by using hierarchical clustering to cluster the intensity values.

18 October 2016
Verified
Conference Paper
Closed access
VRVille Rantanen
Ville Rantanen
MIMirja Ilves
Mirja Ilves
AVAntti Vehkaoja
Antti Vehkaoja
AKAnton Kontunen
Anton Kontunen
JLJani Lylykangas
Jani Lylykangas
JLJukka Lekkala
Jukka Lekkala
A survey on the feasibility of surface electromyography (EMG) measurements in facial pacing is presented. Pacing for unilateral facial paralysis consists of the measurement of activity from the healthy side of the face and functional electrical stimulation to reanimate the paralyzed one. The goal of this study is to evaluate the feasibility of surface EMG as a measurement method to detect muscle activations and to determine their intensities. Prior work is discussed, and results from experiments where 12 participants carried out a set of facial movements are presented. EMG was registered from zygomaticus major (smile), orbicularis oris (lip pucker), orbicularis oculi (eye blink), corrugator supercilii (frown), and masseter (chew). Most important facial functions that are limited due to the paralysis are blinking, smiling, and puckering. With majority of the participants, crosstalk between the measured EMG channels was found to be acceptably small to be able to pace smiling and puckering based on detecting their contraction intensities from the healthy side. However, pacing blinking based on orbicularis oculi EMG measurement does not seem possible due to crosstalk from other muscles, but the electro-oculographic (EOG) signals that couple to the same measurement channel could help to detect eye blinks and trigger stimuli. Futhermore, masseter greatly disturbs EMG measurement of most facial muscles, which needs to be addressed in the pacing system to avoid falsely interpreting its activity as the activity of another muscle.