Laurent Zieleskiewicz

Dr. Laurent Zieleskiewicz


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2020 in Intensive Care Medicine
Verified
Journal Article
Closed access
PDF file
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
TMThibaut Markarian
Thibaut Markarian
ALAlexandre Lopez
Alexandre Lopez
CTChloé Taguet
Chloé Taguet
NMNeyla Mohammedi
Neyla Mohammedi
ONOn Behalf Of The Azurea Network
On Behalf Of The Azurea Network

22 January 2021 in Critical Care
Verified
Journal Article
Open access
PDF file
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
ALAlexandre Lopez
Alexandre Lopez
SHSami Hraiech
Sami Hraiech
KBKarine Baumstarck
Karine Baumstarck
BPBruno Pastene
Bruno Pastene
MLMarc Leone
Marc Leone
Background: Rapid response teams are intended to improve early diagnosis and intervention in ward patients who develop acute respiratory or circulatory failure. A management protocol including the use of a handheld ultrasound device for immediate point-of-care ultrasound (POCUS) examination at the bedside may improve team performance. The main objective of the study was to assess the impact of implementing such a POCUS-guided management on the proportion of adequate immediate diagnoses in two groups. Secondary endpoints included time to treatment and patient outcomes. Methods: A prospective, observational, controlled study was conducted in a single university hospital. Two teams alternated every other day for managing in-hospital ward patients developing acute respiratory and/or circulatory failures. Only one of the team used an ultrasound device (POCUS group). Results: We included 165 patients (POCUS group 83, control group 82). Proportion of adequate immediate diagnoses was 94% in the POCUS group and 80% in the control group (p = 0.009). Time to first treatment/intervention was shorter in the POCUS group (15 [10–25] min vs. 34 [15–40] min, p < 0.001). In-hospital mortality rates were 17% in the POCUS group and 35% in the control group (p = 0.007), but this difference was not confirmed in the propensity score sample (29% vs. 34%, p = 0.53). Conclusion: Our study suggests that protocolized use of a handheld POCUS device at the bedside in the ward may improve the proportion of adequate diagnosis, the time to initial treatment and perhaps also survival of ward patients developing acute respiratory or circulatory failure. Clinical Trial Registration NCT02967809. Registered 18 November 2016, https://clinicaltrials.gov/ct2/show/NCT02967809.

26 July 2018 in Anaesthesia
Verified
Journal Article
Closed access
PDF file
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
LBL. Bouvet
L. Bouvet
SES. Einav
S. Einav
GDG. Duclos
G. Duclos
MLM. Leone
M. Leone

16 May 2019 in Critical Care
Verified
Journal Article
Open access
PDF file
AGAzuRea Group
AzuRea Group
CRClaire Roger
Claire Roger
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
CDChristophe DEMATTEI
Christophe DEMATTEI
KLKarim Lakhal
Karim Lakhal
LMLaurent Muller
Laurent Muller
Fluid challenge (FC) is one of the most common practices in Intensive Care Unit (ICU). The present study aimed to evaluate whether echocardiographic assessment of the response to FC at the end of the infusion or 20 min later could affect the results of the FC. This is a prospective, observational, multicenter study including all ICU patients in septic shock requiring a FC of 500 mL crystalloids over 10 min. Fluid responsiveness was defined as a > 15% increase in stroke volume (SV) assessed by velocity-time integral (VTI) measurements at baseline (T0), at the end of FC (T10), then 10 (T20) and 20 min (T30) after the end of FC. From May 20, 2014, to January 7, 2016, a total of 143 patients were enrolled in 11 French ICUs (mean age 64 ± 14 years, median IGS II 53 [43–63], median SOFA score 10 [8–12]). Among the 76/143 (53%) patient responders to FC at T10, 37 patients were transient responders (TR), i.e., became non-responders (NR) at T30 (49%, 95%CI = [37–60]), and 39 (51%, 95%CI = [38–62]) patients were persistent responders (PR), i.e., remained responders at T30. Among the 67 NR at T10, 4 became responders at T30, (6%, 95%CI = [1.9–15.3]). In the subgroup analysis, no statistical difference in hemodynamic and echocardiographic parameters was found between groups. This study shows that 51.3% of initial responders have a persistent response to fluid 30 min after the beginning of fluid infusion and only 41.3% have a transient response highlighting that fluid responsiveness is time dependent. ClinicalTrials.gov , NCT02116413 . Registered on April 16, 2014

1 October 2018 in Injury
Verified
Journal Article
Closed access
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
RFRaphaelle Fresco
Raphaelle Fresco
GDGary Duclos
Gary Duclos
FAFrançois Antonini
François Antonini
CMCalypso Mathieu
Calypso Mathieu
MLMarc Leone
Marc Leone

21 February 2018 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
CNC. Nafati
C. Nafati
MGM. Gardette
M. Gardette
MLMarc Leone
Marc Leone
LRLaurent Reydellet
Laurent Reydellet
VBV. Blasco
V. Blasco
LZLaurent Zieleskiewicz
Laurent Zieleskiewicz
In critical patients, left ventricular ejection fraction and fractional shortening are used to reflect left ventricular systolic function. An emerging technique, two-dimensional-strain echocardiography, allows assessment of the left ventricle systolic longitudinal deformation (global longitudinal strain) and the speed at which this deformation occurs (systolic strain rate). This technique is of increasing use in critical patients in intensive care units and in the peri-operative period where preload constantly varies. Our objective, in this prospective single-center observational study, was to evaluate the effect of fluid resuscitation on two-dimensional-strain echocardiography measurements in preload-dependent critically ill patients. We included 49 patients with preload dependence attested by an increase of at least 10% in the left ventricular outflow track velocity–time integral measured by echocardiography during a passive leg raising maneuver. Echocardiography was performed before fluid resuscitation (echocardiography 1) and after preload independency achievement (echocardiography 2). Two-dimensional-strain echocardiography was feasible in 40 (82%) among the 49 patients. With preload dependence correction, the absolute value of global longitudinal strain and systolic strain rate was significantly increased from, respectively, − 13.3 ± 3.5 to − 18.4% ± 4.5 (p < 0.01) and − 1.11 s−1 ± 0.29 to − 1.55 s−1 ± 0.55 (p < 0.001). The fluid resuscitation affects GLS and SSR in preload-dependent patients, with a shift, for GLS, from pathological to normal values. In critically ill patients, the assessment of the systolic function by two-dimensional-strain echocardiography needs prior evaluation of preload dependency, in order to adequately interpret this variable. Future studies should assess the ability of global longitudinal strain to guide fluid management in the critically ill patients.