Zhangyang Kang

Dr. Zhangyang Kang

School of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou, Henan, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
ZKZhangyang Kang
Zhangyang Kang
ZLZhaoyang Lu
Zhaoyang Lu
GSGangfu Song
Gangfu Song
QYQiongqiong Yao
Qiongqiong Yao
The multi-inlet air-cooled photovoltaic/thermal (PV/T) technology not only avoids the poor heat transfer conditions of single-inlet PV/T air collectors but also reduces photovoltaic (PV) peak temperature and improves solar energy utilization. Since air-cooled PV/T collectors use no more than three inlets, the increase in thermal efficiency is significantly more effective. Therefore, a numerical analysis of an air-cooled PV/T solar collector with two side inlets was performed. The heat transfer efficiency and flow characteristics were then investigated for various air channel configurations. Increasing the area of the second inlet improves thermal and electrical efficiency. As the length ratio of the front and rear airflow channels is reduced, the average outlet temperature first decreases and then increases. The heat-exchanging quantity of the dual-inlet air-cooled PV/T collector is minimal. The thermal efficiency of the dual-inlet air-cooled PV/T collector can be elevated by increasing the angle between the solar panel and the bottom plate. However, the average temperature of the solar panels is increased and the photoelectric conversion efficiency decreased. This design will achieve a reduction in carbon emissions and an increase in the proportion of clean energy in a low- or zero-carbon green building.

21 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZKZhangyang Kang
Zhangyang Kang
WZWu Zhou
Wu Zhou
KQKaijie Qiu
Kaijie Qiu
CWChaojie Wang
Chaojie Wang
ZQZhaolong Qin
Zhaolong Qin
QYQiongqiong Yao
Qiongqiong Yao
The great development of energy storage technology and energy storage materials will make an important contribution to energy saving, reducing emissions and improving energy utilization efficiency. Mobile thermal energy storage (M-TES) technology finds a way to realize value for low-grade heat sources far beyond the demand side. In this paper, an indirect-contact M-TES container is studied using the computational fluid dynamics (CFD) method. By optimizing the heat exchange tube bundle layout and the installed fin structure of the shell and tube type M-TES container, a method of enhancing the charging and discharging efficiency is identified. The peripheral distribution mode of the heat exchanger tubes improves the efficiency of heat charging by 12.6% compared with the traditional uniform layout. The installation of the Y-shaped fins can improve the heat charging efficiency by 8.3%, better than straight fins. Compared with the horizontal installation of Y-shaped fins, the vertical installation of Y-shaped fins is preferred to improve the heat charging efficiency of the M-TES container.

18 September 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZKZhangyang Kang
Zhangyang Kang
RTRufei Tan
Rufei Tan
WZWu Zhou
Wu Zhou
ZQZhaolong Qin
Zhaolong Qin
SLSen Liu
Sen Liu
Featuring phase-change energy storage, a mobile thermal energy supply system (M-TES) demonstrates remarkable waste heat transfer capabilities across various spatial scales and temporal durations, thereby effectively optimizing the localized energy distribution structure—a pivotal contribution to the attainment of objectives such as “carbon peak” and “carbon neutral”. To heighten the efficiency of energy transfer for mobile heating, this research introduces the innovative concept of modular storage and transportation. This concept is brought to life through the development of a meticulously designed modular mobile phase-change energy storage compartment system. Employing computational fluid dynamics (CFD), an in-depth exploration into the performance of the modular M-TES container and the adapted phase-change material (PCM) is conducted. By implementing fin arrangements on the inner wall of the heat storage module, a remarkable upsurge in the liquid phase-transition rate of the phase-change material is achieved in comparison to the design lacking fins—this improvement approximating around 30%. However, it is essential to acknowledge that the augmentation in heat transfer gradually recedes with the proliferation of fins or an escalation in their height. Moreover, the integration of expanded graphite into erythritol emerges as profoundly effective in amplifying the thermal conductivity of the PCM. Notably, with the addition of a 15.2% volume fraction of expanded graphite to erythritol, the duration of heat storage experiences a drastic reduction to nearly 10% of its original duration, thereby signifying a momentous advancement in thermal performance.

30 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZGZhanjun Guo
Zhanjun Guo
WZWu Zhou
Wu Zhou
SLSen Liu
Sen Liu
ZKZhangyang Kang
Zhangyang Kang
RTRufei Tan
Rufei Tan
Internationally, energy-storage technologies have facilitated the large-scale utilization of renewable energy, reducing reliance on conventional power generation and enhancing energy efficiency. In the pursuit of strengthening the efficiency of phase-change energy-storage systems, the focus lies on further enhancing the efficiency of vertical shell-and-tube energy-storage systems. This study investigates the influence of two different heat-transfer fluid (HTF) injection directions on the melting of phase-change materials (PCM) in a vertical shell-and-tube latent heat storage (LHS) system. The melting behavior of PCM is analyzed under both pure conduction and natural convection conditions. The research findings reveal that during the initial melting stage, both HTF injection methods primarily rely on thermal conduction, resulting in no significant changes in PCM melting. However, in the later stages of natural convection, bottom HTF injection exhibits superior heat-transfer efficiency compared to top injection. Under a constant volume of phase-change material, both pipe length and pipe thickness affect the PCM melting process. As the pipe length increases within the range of 1.6 m to 0.2 m, the PCM melting time also increases. The results show that the melting time of the PCM is reduced by almost 15,000 s when the tube length H exceeds 800 mm, regardless of whether the heat-transfer fluid is injected at the top or bottom. In this paper, we also obtained results that the three composites containing 10% expanded graphite save 5.3%, 10.2%, and 14.3% of melting time, respectively, compared to pure paraffin when H = 200 mm and top injection are considered. For bottom injection, the three composites saved 7.7%, 12.5%, and 17.2% of melting time, respectively. This further emphasizes the more significant effect of priming in improving melting time.

15 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
ZKZhangyang Kang
Zhangyang Kang
MHMaogang He
Maogang He
GLGuangxuan Lu
Guangxuan Lu
In this study, the phase diagram of the NaCl+RbCl binary system was measured using differential scanning calorimetry, and the measured molar percentages of the binary mixture RbCl ranged from 12 to 97 mol%, updating and extending the experimental data for this binary system. The liquid phase of this system was thermodynamically modeled using a modified quasichemical model, and a computer optimization program for evaluation of the experimental data on phase equilibria and other thermodynamic data was developed based on this model. All thermodynamic models of the NaCl+RbCl binary system were constructed; calculations of the phase diagram, enthalpy of mixing, and activity coefficient of NaCl of the NaCl+RbCl binary system were completed using the obtained model parameters; and the calculated eutectic point positions were xRbCl = 0.567 and 550.2 °C. The calculated results were able to reproduce the various types of experimental data well, and the thermodynamic self-consistency between different types of experimental data was demonstrated.

28 August 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
ZGZhanjun Guo
Zhanjun Guo
SLSen Liu
Sen Liu
JWJiali Wang
Jiali Wang
YXYanping Xu
Yanping Xu
ZKZhangyang Kang
Zhangyang Kang
JZJinsheng Zhang
Jinsheng Zhang
China’s rapid economic development and rising energy consumption have led to significant challenges in energy supply and demand. While wind and solar energy are clean alternatives, they do not always align with the varying energy needs across different times and regions. Concurrently, China produces substantial amounts of industrial waste heat annually. Effective recycling of this waste heat could substantially mitigate energy supply and demand issues. The Mobile Thermal Energy Storage (M-TES) system is a key solution to address these challenges, as it helps manage the uneven distribution of energy over time and space. This article establishes a packaged M-TES based on a plate-type phase change unit. Based on different placement methods of the plate-type phase change unit, different inlet temperatures and phase change temperature differences, and different inlet and outlet directions, the complete charging and discharging process of the packaged phase change thermal storage system was simulated using ANSYS FLUENT 2022 R1 software. The results showed that during the heating process of the entire system, the horizontal placement of the plate-type phase change unit and the inlet and outlet methods of the heat transfer fluid (HTF) significantly improved the heating effect of the system, increasing it by 15.9%. Increasing the temperature difference between the inlet temperature of the heat transfer fluid and the melting temperature of the phase change material (PCM) from 4 K to 19 K can increase the melting rate of PCM by approximately 54.9%