Miyuki Noguchi

Dr. Miyuki Noguchi


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MNMiyuki Noguchi
Miyuki Noguchi
Atsushi MizukoshiAtsushi Mizukoshi
Atsushi Mizukoshi
YYYukio Yanagisawa
Yukio Yanagisawa
AYAkihiro Yamasaki
Akihiro Yamasaki
We measured temporal changes in concentrations of total volatile organic compounds (TVOCs) and individual volatile organic compounds in a newly built daycare center. The temporal changes of the TVOC concentrations were monitored with a photo ionization detector (PID), and indoor air was sampled and analyzed by Gas Chromatography/Mass Spectrometry (GC/MS) and high performance liquid chromatography (HPLC) to determine the concentrations of the constituent VOCs. The measurements were performed just after completion of the building and again 3 months after completion. The TVOC concentration exceeded 1000 µg·m−3 for all the sampling locations just after completion of building, and decreased almost one tenth after 3 months, to below the guideline values of the TVOC in Japan at 400 µg·m−3. The concentrations of the target VOCs of which the indoor concentrations are regulated in Japan were below the guideline values for all the cases. The air-exchange rates were determined based on the temporal changes of the TVOC concentrations, and it was found that the countermeasure to increase the air exchange rate successfully decrease the TVOC concentration level in the rooms.

MNMiyuki Noguchi
Miyuki Noguchi
STSaya Tanaka
Saya Tanaka
KWKaede Watanabe
Kaede Watanabe
AYAkihiro Yamasaki
Akihiro Yamasaki
We examined the correlation between the odor concentration and the chemical composition of environmental tobacco smoke (ETS). Three types of ETS samples were prepared: secondhand smoke (SHS), thirdhand smoke (THS), and field ETS samples from an outside smoking area. The odor concentrations of the ETS, SHS, and THS samples were determined by the triangle-odor-bag method, and the chemical compositions were determined by proton transfer mass spectrometry. The odor concentration of the SHS samples was three or four orders of magnitude higher than that of the field ETS samples, and three orders of magnitude higher than that of the THS samples. The concentration ratios of the constituent chemicals in THS to those in SHS were about 10−4, corresponding to the ratio of the odor concentration. The concentration ratios of the constituent chemicals in the field ETS samples were much lower than the ratios of the odor concentrations. This suggests that the main contributing components to the odor of the field ETS samples are different from those in SHS and THS. The main contributors of the odor in the field ETS samples could be acetaldehyde, acetonitrile, acetic acid, and other unknown components with a mass-to-charge ratio (m/z) of 39 and 43.

Atsushi MizukoshiAtsushi Mizukoshi
Atsushi Mizukoshi
KKKazukiyo Kumagai
Kazukiyo Kumagai
NYNaomichi Yamamoto
Naomichi Yamamoto
MNMiyuki Noguchi
Miyuki Noguchi
KYKazuhiro Yoshiuchi
Kazuhiro Yoshiuchi
YYYukio Yanagisawa
Yukio Yanagisawa
In-situ real-time monitoring of volatile organic compound (VOC) exposure and heart rate variability (HRV) were conducted for eight multiple chemical sensitivity (MCS) patients using a VOC monitor, a Holter monitor, and a time-activity questionnaire for 24 h to identify the relationship between VOC exposure, biological effects, and subjective symptoms in actual life. The results revealed no significantly different parameters for averaged values such as VOC concentration, HF (high frequency), and LF (low frequency) to HF ratio compared with previous data from healthy subjects (Int. J. Environ. Res. Public Health 2010, 7, 4127–4138). Significant negative correlations for four subjects were observed between HF and amounts of VOC change. These results suggest that some patients show inhibition of parasympathetic activities along with VOC exposure as observed in healthy subjects. Comparing the parameters during subjective symptoms and normal condition, VOC concentration and/or VOC change were high except for one subject. HF values were low for five subjects during subjective symptoms. Examining the time-series data for VOC exposure and HF of each subject showed that the subjective symptoms, VOC exposure, and HF seemed well related in some symptoms. Based on these characteristics, prevention measures of symptoms for each subject may be proposed.

SSShintaro Shirato
Shintaro Shirato
TNTakashi Nakamura
Takashi Nakamura
Atsushi MizukoshiAtsushi Mizukoshi
Atsushi Mizukoshi
MNMiyuki Noguchi
Miyuki Noguchi
AYAkihiro Yamasaki
Akihiro Yamasaki
YYYukio Yanagisawa
Yukio Yanagisawa
Continuous ambient air monitoring systems have been introduced worldwide. However, such monitoring forces autonomous communities to bear a significant financial burden. Thus, it is important to identify pollutant-monitoring stations that are less efficient, while minimizing loss of data quality and mitigating effects on the determination of spatiotemporal trends of pollutants. This study describes a procedure for optimizing a constant ambient air monitoring system in the Kanto region of Japan. Constant ambient air monitoring stations in the area were topologically classified into four groups by cluster analysis and principle component analysis. Then, air pollution characteristics in each area were reviewed using concentration contour maps and average pollution concentrations. We then introduced three simple criteria to reduce the number of monitoring stations: (1) retain the monitoring station if there were similarities between its data and average data of the group to which it belongs; (2) retain the station if its data showed higher concentrations; and (3) retain the station if the monitored concentration levels had an increasing trend. With this procedure, the total number of air monitoring stations in suburban and urban areas was reduced by 36.5%. The introduction of three new types of monitoring stations is proposed, namely, mobile, for local non-methane hydrocarbon pollution, and Ox-prioritized.