The risk of transfusion-transmitted hepatitis E virus (HEV) infections by contaminated blood products remains unknown. In the present study, we evaluated and compared different nucleic acid amplification technique (NAT) methods for the detection of HEV in blood components. Minipools of a total of 16,125 individual blood donors were screened for the presence of HEV RNA using the highly sensitive RealStar HEV RT-PCR kit, revealing a minimum detection limit of 4.66 IU/ml. Thirteen donors were HEV RNA positive (0.08%), and of these donors, only three already showed reactive IgM antibody titers. The detected HEV strains all belonged to genotype 3 and were most closely related to German HEV strains from wild boars and pigs as well as from human hepatitis E cases. Furthermore, HEV RNA and HEV-specific IgM and IgG titers were determined in 136 blood donors with elevated alanine aminotransferase (ALT) levels and in 200 donors without pathological findings. HEV RNA was not detectable, but 8.08% (elevated ALT) and 0.5% (nonelevated ALT) of donors showed reactive HEV IgM titers. The overall seroprevalence rate of HEV IgG amounted to 5.94% (elevated ALT, 5.88%; nonelevated ALT, 6.0%). The clinical relevance of transfusion-associated hepatitis E infection still requires further investigation. However, in connection with raising concerns regarding blood safety, our NAT method provides a sensitive possibility for HEV testing.
In the present study, a novel broad-range real-time PCR was developed for the rapid detection of human pathogenic fungi. The assay targets a part of the 28S large-subunit ribosomal RNA (rDNA) gene. We investigated its application for the most important human pathogenic fungal genera, including Aspergillus, Candida, Cryptococcus, Mucor, Penicillium, Pichia, Microsporum, Trichophyton , and Scopulariopsis . Species were identified in PCR-positive reactions by direct DNA sequencing. A noncompetitive internal control was applied to prevent false-negative results due to PCR inhibition. The minimum detection limit for the PCR was determined to be one 28S rDNA copy per PCR, and the 95% detection limit was calculated to 15 copies per PCR. To assess the clinical applicability of the PCR method, intensive-care patients with artificial respiration and patients with infective endocarditis were investigated. For this purpose, 76 tracheal secretion samples and 70 heart valve tissues were analyzed in parallel by real-time PCR and cultivation. No discrepancies in results were observed between PCR analysis and cultivation methods. Furthermore, the application of the PCR method was investigated for other clinical specimens, including cervical swabs, nail and horny skin scrapings, and serum, blood, and urine samples. The combination of a broad-range real-time PCR and direct sequencing facilitates rapid screening for fungal infection in various clinical specimens.
1 February 2011 in Systematic and Applied Microbiology
Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2, a new member of the genus Betacoronavirus, is a pandemic virus, which has caused numerous fatalities, particularly in the elderly and persons with underlying morbidities. At present, there are no approved vaccines nor antiviral therapies available. The detection and quantification of SARS-CoV-2-neutralizing antibodies plays a crucial role in the assessment of the immune status of convalescent COVID-19 patients, evaluation of recombinant therapeutic antibodies, and the evaluation of novel vaccines. To detect SARS-CoV-2-neutralizing antibodies, classically, a virus-neutralization test has to be performed at biosafety level 3, considerably limiting the general use of this test. In the present work, a biosafety level 1 pseudotype virus assay based on a propagation-incompetent vesicular stomatitis virus (VSV) has been used to determine the neutralizing antibody titers in convalescent COVID-19 patients. The neutralization titers in serum of two independently analyzed patient cohorts were available within 18 h and correlated well with those obtained with a classical SARS-CoV-2 neutralization test (Pearson correlation coefficients of r = 0.929 and r = 0.939, respectively). Most convalescent COVID-19 patients had only low titers of neutralizing antibodies (ND50 < 320). The sera of convalescent COVID-19 patients also neutralized pseudotype virus displaying the SARS-CoV-1 spike protein on their surface, which is homologous to the SARS-CoV-2 spike protein. In summary, we report a robust virus-neutralization assay, which can be used at low biosafety level 1 to rapidly quantify SARS-CoV-2-neutralizing antibodies in convalescent COVID-19 patients and vaccinated individuals.
The risk and importance of transfusion-transmitted hepatitis E virus (TT-HEV) infections by contaminated blood products is currently a controversial discussed topic in transfusion medicine. The infectious dose, in particular, remains an unknown quantity. In the present study, we illuminate and review this aspect seen from the viewpoint of a blood donation service with more than 2 years of experience in routine HEV blood donor screening. We systematically review the actual status of presently known cases of TT-HEV infections and available routine NAT-screening assays. The review of the literature revealed a significant variation regarding the infectious dose causing hepatitis E. We also present the outcome of six cases confronted with HEV-contaminated blood products, identified by routine HEV RNA screening of minipools using the highly sensitive RealStar HEV RT-PCR Kit (95% LOD: 4.7 IU/mL). Finally, the distribution of viral RNA in different blood components [plasma, red blood cell concentrate (RBC), platelet concentrates (PC)] was quantified using the first WHO international standard for HEV RNA for NAT-based assays. None of the six patients receiving an HEV-contaminated blood product from five different donors (donor 1: RBC, donor 2–5: APC) developed an acute hepatitis E infection, most likely due to low viral load in donor plasma (<100 IU/mL). Of note, the distribution of viral RNA in blood components depends on the plasma content of the component; nonetheless, HEV RNA could be detected in RBCs even when low viral plasma loads of 100–1,000 IU/mL are present. Comprehensive retrospective studies of TT-HEV infection offered further insights into the infectivity of HEV RNA-positive blood products. Minipool HEV NAT screening (96 samples) of blood donations should be adequate as a routine screening assay to identify high viremic donors and will cover at least a large part of viremic phases.
Background: A broad spectrum of pathogens is causative for respiratory tract infections, but symptoms are mostly similar. Therefore, the identification of the causative viruses and bacteria is only feasible using multiplex PCR or several monoplex PCR tests in parallel. Methods: The analytical sensitivity of three multiplex PCR assays, RespiFinder-19, RespiFinder-SMART-22 and xTAG-Respiratory-Virus-Panel-Fast-Assay (RVP), were compared to monoplex real-time PCR with quantified standardized control material. All assays include the most common respiratory pathogens. Results: To compare the analytical sensitivity of the multiplex assays, samples were inoculated with 13 different quantified viruses in the range of 101 to 105 copies/ml. Concordant results were received for rhinovirus, whereas the RVP detected influenzavirus, RSV and hMPV more frequently in low concentrations. The RespiFinder-19 and the RespiFinder-SMART-22 showed a higher analytical sensitivity for adenoviruses and coronaviruses, whereas the RVP was incapable to detect adenovirus and coronavirus in concentrations of 104 copies/ml. The RespiFinder-19 and RespiFinder-SMART-22A did not detect influenzaviruses (104 copies/ml) and RSV (103 copies/ml). The detection of all 13 viruses in one sample was only achieved using monoplex PCR. To analyze possible competitive amplification reactions between the different viruses, samples were further inoculated with only 4 different viruses in one sample. Compared to the detection of 13 viruses in parallel, only a few differences were found. The incidence of respiratory viruses was compared in tracheal secretion (TS) samples (n = 100) of mechanically ventilated patients in winter (n = 50) and summer (n = 50). In winter, respiratory viruses were detected in 32 TS samples (64%) by RespiFinder-19, whereas the detection rate with RVP was only 22%. The most frequent viruses were adenovirus (32%) and PIV-2 (20%). Multiple infections were detected in 16 TS samples (32%) by RespiFinder-19. Fewer infections were found in summer (RespiFinder-19: 20%; RVP: 6%). All positive results were verified using monoplex PCR. Conclusions: Multiplex PCR tests have a broad spectrum of pathogens to test at a time. Analysis of multiple inoculated samples revealed a different focus of the detected virus types by the three assays. Analysis of clinical samples showed a high concordance of detected viruses by the RespiFinder-19 compared to monoplex tests.