๋Jagraphon obma

Dr. ๋Jagraphon obma

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2023 in EUREKA: Physics and Engineering
Verified
Journal Article
Open access
PDF file
๋O๋Jagraphon obma
๋Jagraphon obma
AJAdirek Jantakun
Adirek Jantakun
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
ASAtirarj Suksawad
Atirarj Suksawad
The topic of this article is the design of a fully balanced first-order high-pass filter and its two circuits. The first circuit is a fully balanced current-tunability first-order high-pass filter consisting of four NPN transistors and a single capacitor, which is a simple design and quite compact. The pole frequency can be adjusted with a bias current. The results of the first circuit shows the phase and gain responses, the phase and gain responses when adjusted with a bias current, the time-domain response, and the harmonic spectrum. However, this circuit found a flaw in the temperature that affects the pole frequency, and total harmonic distortion is relatively high. Therefore, the second circuit improves defects by the CAPRIO technique to reduce the total harmonic distortion, and the resistors in the circuit are added to the design to replace the resistance and the effect of temperature on the properties of the transistor. This circuit consists of four NPN transistors, four resistors, and a single capacitor. The resistors in this circuit can be adjusted to change the pole frequency and voltage gain. The results of the second circuit show the gain and phase responses of the proposed circuits, the phase and gain responses when adjusted to the value of the resistor, the phase and gain responses at various temperatures, as well as their time-domain responses and total harmonic signal distortion. The all-pass filter is also made using the filter introduced in the second circuit because of its voltage gain-adjustable property. So, if the suggested circuit is constructed in combination with a buffer circuit to make it feasible to function as an all-pass filter, the result will be an all-pass filter. In accordance with the results of this study, we have introduced a design for a high-pass filter to reduce total harmonic distortion and the effect of temperature

31 January 2025 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
๋O๋Jagraphon obma
๋Jagraphon obma
SASitthisak Audomsi
Sitthisak Audomsi
KAKittipong Ardhan
Kittipong Ardhan
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
NCNatpapha Chansom
Natpapha Chansom
Maintaining frequency stability in hybrid renewable-integrated power systems remains a critical challenge due to the inherent variability and uncertainty of photovoltaic–thermal (PV–T) energy sources. Traditional proportional–integral (PI) controllers, optimized using conventional metaheuristic algorithms such as the Whale Optimization Algorithm (WOA), Firefly Algorithm (FA), and Salp Swarm Algorithm (SSA), often suffer from limitations including slow convergence, premature convergence to local optima, and reduced robustness under severe load disturbances. The research contribution is the development and systematic evaluation of a chess algorithm (CA)-based PI controller tuning approach for enhancing load frequency control (LFC) in hybrid PV–T systems. Unlike population-based methods, the CA employs chess-inspired strategic decision-making processes, which improve the search efficiency and the ability to escape local optima in high-dimensional optimization problems. In this study, the proposed CA-based optimization method is applied to a two-area hybrid PV–T power system, where the system is subject to various operating conditions, including solar radiation fluctuations and step load perturbations. The tuning of PI controller parameters is performed using the integral of time-weighted absolute error (ITAE) as the objective function. Simulation results demonstrate that the CA-optimized PI controller achieves superior performance in minimizing overshoot, undershoot, and settling time when compared with controllers optimized by WOA, FA, and SSA. Specifically, the CA approach achieves faster stabilization and lower frequency deviations, highlighting its potential for real-time implementation and enhanced grid reliability. Future work will explore the scalability of the proposed method to multi-area power systems and evaluate its computational efficiency through hardware-in-the-loop validation.

13 February 2026 in IEEE Access
Verified
Journal Article
Open access
SASitthisak Audomsi
Sitthisak Audomsi
CAChatmongkol Areeyat
Chatmongkol Areeyat
๋O๋Jagraphon obma
๋Jagraphon obma
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
The Load Frequency Control (LFC) challenge in multi-source power systems increasingly complicates with the integration of renewable energy, owing to frequent nonlinearities, uncertainties, and disturbances. Conventional controllers such as proportional-integral-derivative (PID) and adaptive PI–1PD frequently exhibit constraints in terms of stability and convergence speed. This study proposes an optimal fuzzy logic two-degree-of-freedom PID controller (Optimal–FL–2DOF–PID) tuned via a metaheuristic chess optimizer (CO), which is a novel optimization algorithm introduced in this study. The performance was evaluated in MATLAB/Simulink under two scenarios: (i) a 5% Step Load Perturbation (SLP) and (ii) a Random Step Load Pattern (RSLP) increment-decrement that effectively mirrors real-world applications. The simulation results demonstrate that the Optimal–FL–2DOF–PID controller surpasses all the comparable controllers. In Scenario 1, the proposed controller attains the lowest objective function—Integral of Timeweighted Absolute Error (ITAE) of 4.6692 corresponding to reductions of 25.31%, 43.05%, and 41.92% relative to 2DOF–PID, PID, and PI–1PD, respectively (and 1.92% relative to the None–optimal–FL–2DOF– PID), overshoot (OS), undershoot (US), settling time (ST) 13–15 s, and tie-line power deviations are likewise reduced. In Scenario 2, using the corresponding optimum parameters from Scenario 1, the Optimal–FL– 2DOF–PID controller achieves ITAE = 395.72, which is lower than the None–optimal–FL–2DOF–PID controller design by 46.52%, and lower than 2DOF–PID, PID, and PI–1PD by 29.73%, 22.19%, and 9.68%, respectively. The frequency–channel ST is 150–180 s, whereas tie-line exchanges settled in the mid–150 s with visibly smoother profiles. These results indicate that Optimal–FL–2DOF–PID provides robust and efficient frequency regulation for multi-area systems under significant uncertainty, supporting deployment in future renewable energy-integrated power systems.

6 October 2025 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
SASitthisak Audomsi
Sitthisak Audomsi
CAChatmongkol Areeyat
Chatmongkol Areeyat
๋O๋Jagraphon obma
๋Jagraphon obma
XYXiaoqing Yang
Xiaoqing Yang
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
This study investigates the optimization of a two-degree-of-freedom PID (2DOF-PID) controller using the Ant Lion Optimizer (ALO) for enhanced frequency regulation in a hybrid Photovoltaic (PV)–Reheat Thermal Power System under sudden load disturbances. To benchmark performance, conventional PID and PI controllers were also tested to assess their ability to minimize the frequency fluctuations and manage the inter-area power exchanges. Simulations were carried out in MATLAB/Simulink using a dual-area dynamic model, and the performance was evaluated based on standard control metrics, including the settling time, overshoot/undershoot, and the Integral of Absolute Error (IAE). The results indicate that the ALO-optimized 2DOF-PID controller reduced the average settling time by nearly 40% and IAE by 12.6%, compared to the best-performing PID controller in the benchmark group. These findings highlight the advantages of combining the 2DOF-PID architecture with an evolutionary optimization strategy, offering improved dynamic and nonlinear control performance. The proposed approach shows strong potential for application in next-generation renewable energy systems and smart grids.

19 June 2025 in International Journal of Robotics and Control Systems
Verified
Journal Article
Open access
PDF file
CAChatmongkol Areeyat
Chatmongkol Areeyat
SASitthisak Audomsi
Sitthisak Audomsi
๋O๋Jagraphon obma
๋Jagraphon obma
XYXiaoqing Yang
Xiaoqing Yang
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
Renewable energy sources such as solar and wind are increasingly integrated into multi-area power systems. However, their fluctuating and unpredictable characteristics pose challenges for sustaining system stability. Therefore, automatic generation control (AGC) is essential for the continual regulation of power and frequency in the system. This article presents the use of a Proportional–Integral–Derivative plus second-order derivative (PID+DD) controller for load frequency control in a three-area multi-source power system, which includes a thermal reheat power plant with a generation rate constraint (GRC) representing the maximum permissible change rate of generation output of 5% per min , a hydroelectric power plant with a GRC of 370% per min, and a wind power plant where wind speeds vary across areas. The power generation ratio of the three areas is 1:2:4. The controller parameters were tuned using a Chess Optimizer (CO), a metaheuristic inspired by chess move complexity and planning, with specific weights assigned to each type of chess piece. Two load change scenarios were studied: a 10% step load perturbation (10% SLP) and a random load pattern (RLP). Furthermore, experimental results based on the Integral of Time-weighted Absolute Error (ITAE) indicate that the PID+DD controller tuned by the Chess Optimizer achieved the lowest steady-state error in both scenarios (10% SLP and RLP). In Case 1 (SLP), it achieved an ITAE of 25.5072, representing a 9.70% reduction compared to the PID controller and a 1.96% reduction compared to the PI controller. In Case 2 (RLP), it achieved an ITAE of 88.0654, representing a 1.14% reduction compared to the PID controller and a 2.03% reduction compared to the PI controller. These improvements contribute to enhanced oscillation damping, reduced overshoot and undershoot, and improved frequency stability, demonstrating the practical applicability of the proposed approach in future smart grids with high renewable energy penetration.

27 May 2024 in EUREKA: Physics and Engineering
Verified
Journal Article
Open access
PDF file
ACAdithep Chaisaward
Adithep Chaisaward
KAKittipong Ardhan
Kittipong Ardhan
๋O๋Jagraphon obma
๋Jagraphon obma
WSWorawat Sa-ngiamvibool
Worawat Sa-ngiamvibool
This article presents a method of designing an optimal Proportional-Integral-Derivative (PID) controller for Automatic Generation Control (AGC) of a two-area interconnected thermal system. In addition, an application of Salp Swarm Algirithm (SSA) in order to design PID controllers is proposed. A method inspired by salp foraging behavior. The journey of the Salp group in the sea, by random the population of the salp and separated into leader salp and follower salp. The leader moves towards the food source and the rest of the followers follow the salp positioned in front of themselves. The parameters of PID were achieved by trial and error methods by designers. As an interconneted thermal power system with a Governor Deadband (GDB) is nonlinear and dynamic system, the Integral Squared Error (ISE) criterion has been used as objective function to find optimum controller gain. In order to solve this problem, SSA is proposed to concurrently tune PID gains of the PID controllers to minimize frequency deviations and tie-line power deviations by simulation the interconnected thermal power system .Compare of tuning PID controller from each optimization technique SSA and PSO .Simulation results clearly show that the performance of the system after taking SLP into the interconnected thermal power system that tuning by SSA and PSO and the robustness of the optimal PID controllers are superior to the conventional PID controllers in terms of settling time (–10.46 % in area 1, +0.87 % in area 2 and +0.57 % in power tie-line), overshoot (–10.61 % in area 1 and –10.87 % in area 2) that obtain by (SSA) method less value than the value that obtain by (PSO) method and the power tie-line. Integral Absolute Error (IAE) (–0.38 %) that obtain by (SSA) few errors. Comparisons to the tuned with Particle Swarm Optimization (PSO) approaches is also included