Mahsa Khalili

Mahsa Khalili


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMahsa Khalili
Mahsa Khalili
SLSaud Lingawi
Saud Lingawi
JHJacob Hutton
Jacob Hutton
CFChristopher B. Fordyce
Christopher B. Fordyce
JCJim Christenson
Jim Christenson
CKCalvin Kuo
Calvin Kuo
Out-of-hospital cardiac arrest (OHCA) is a global health problem affecting approximately 4.4 million individuals yearly. OHCA has a poor survival rate, specifically when unwitnessed (accounting for up to 75% of cases). Rapid recognition can significantly improve OHCA survival, and consumer wearables with continuous cardiopulmonary monitoring capabilities hold potential to “witness” cardiac arrest and activate emergency services. In this study, we used an arterial occlusion model to simulate cardiac arrest and investigated the ability of infrared photoplethysmogram (PPG) sensors, often utilized in consumer wearable devices, to differentiate normal cardiac pulsation, pulseless cardiac (i.e., resembling a cardiac arrest), and non-physiologic (i.e., off-body) states. Across the classification models trained and evaluated on three anatomical locations, higher classification performances were observed on the finger (macro average F1-score of 0.964 on the fingertip and 0.954 on the finger base) compared to the wrist (macro average F1-score of 0.837). The wrist-based classification model, which was trained and evaluated using all PPG measurements, including both high- and low-quality recordings, achieved a macro average precision and recall of 0.922 and 0.800, respectively. This wrist-based model, which represents the most common form factor in consumer wearables, could only capture about 43.8% of pulseless events. However, models trained and tested exclusively on high-quality recordings achieved higher classification outcomes (macro average F1-score of 0.975 on the fingertip, 0.973 on the finger base, and 0.934 on the wrist). The fingertip model had the highest performance to differentiate arterial occlusion pulselessness from normal cardiac pulsation and off-body measurements with macro average precision and recall of 0.978 and 0.972, respectively. This model was able to identify 93.7% of pulseless states (i.e., resembling a cardiac arrest event), with a 0.4% false positive rate. All classification models relied on a combination of time-, power spectral density (PSD)-, and frequency-domain features to differentiate normal cardiac pulsation, pulseless cardiac, and off-body PPG recordings. However, our best model represented an idealized detection condition, relying on ensuring high-quality PPG data for training and evaluation of machine learning algorithms. While 90.7% of our PPG recordings from the fingertip were considered of high quality, only 53.2% of the measurements from the wrist passed the quality criteria. Our findings have implications for adapting consumer wearables to provide OHCA detection, involving advancements in hardware and software to ensure high-quality measurements in real-world settings, as well as development of wearables with form factors that enable high-quality PPG data acquisition more consistently. Given these improvements, we demonstrate that OHCA detection can feasibly be made available to anyone using PPG-based consumer wearables.

27 April 2021 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Closed access
MKMahsa Khalili
Mahsa Khalili
AEAngela Eugenio
Angela Eugenio
AWAllison Wood
Allison Wood
MLMachiel Van der Loos
Machiel Van der Loos
W. Ben MortensonW. Ben Mortenson
W. Ben Mortenson
JBJaimie Borisoff
Jaimie Borisoff
The study had three main objectives. (1) To investigate the perceived impact of power-assist devices (PADs) on manual wheelchair (MWC) user mobility. (2) To compare perceptions about different type...

22 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MKMahsa Khalili
Mahsa Khalili
GKGarrett Kryt
Garrett Kryt
W. Ben MortensonW. Ben Mortenson
W. Ben Mortenson
HLHendrik F. Machiel Van der Loos
Hendrik F. Machiel Van der Loos
JBJaimie Borisoff
Jaimie Borisoff
Pushrim-activated power-assisted wheels (PAPAWs) are assistive technologies that use force sensor data to provide on-demand propulsion assistance to manual wheelchair users. However, available data about kinetic and kinematic of PAPAW use are mainly limited to experiments performed on a treadmill or using a dynamometer. In this work, we performed experiments to gather kinetics of wheelchair propulsion and kinematics of wheelchair motion for a variety of over-ground wheelchair maneuvers with a manual wheelchair with and without PAPAWs. Our findings revealed that using PAPAWs can significantly reduce the propulsion effort and push frequency. Both linear and angular velocities of the wheelchair were significantly increased when using PAPAWs. Less force and push frequency could potentially reduce risk of chronic upper limb injury. Higher linear velocity could be desirable for various daily life activities; however; the increase in the angular velocity could lead to unintended deviations from a desired path. Future research could investigate PAPAW controllers that amplify the desired intentions of users while mitigating any unwanted behaviours.

24 June 2021 in Assistive Technology
Verified
Journal Article
Closed access
MKMahsa Khalili
Mahsa Khalili
CJChelsea Jonathan
Chelsea Jonathan
NHNicole Hocking
Nicole Hocking
MLMike Van Der Loos
Mike Van Der Loos
W. Ben MortensonW. Ben Mortenson
W. Ben Mortenson
JBJaimie F. Borisoff
Jaimie F. Borisoff
We evaluated perceived autonomy among users of different types of wheeled mobility assistive devices (WMADs) across five environments and identified the effect on user autonomy due to specific device characteristics. A study-specific questionnaire was used to assess satisfaction with autonomy of WMAD users in the Home, Buildings Outside of the Home, Outdoor Built, Outdoor Natural Environment, and Transportation. For each environment, 15 contextual factors were rated for their impact on participants’ autonomy. Our results revealed that manual wheelchair with add-on (MWC+AO) users had higher overall satisfaction with their autonomy compared to other WMAD users. MWC+AO users reported higher satisfaction with autonomy due to their health conditions compared to other WMAD users across all environments. In Outdoor Natural Environments, MWC+AO users had the highest satisfaction with autonomy across all factors except for negotiating hills. When performing activities in Buildings, MWC users with and without add-ons reported higher satisfaction for all factors compared to power wheelchair users, except for maneuverability on different surfaces. Satisfaction with autonomy regarding contextual factors varied among WMAD users, however, MWC+AO(s) appeared to provide a more balanced sense of autonomy across most factors and environments. More in-depth investigations are required to evaluate impacts of add-on use on autonomy.

3 October 2021 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Closed access
MKMahsa Khalili
Mahsa Khalili
CJChelsea Jonathan
Chelsea Jonathan
NHNicole Hocking
Nicole Hocking
MLMachiel Van der Loos
Machiel Van der Loos
W. Ben MortensonW. Ben Mortenson
W. Ben Mortenson
JBJaimie Borisoff
Jaimie Borisoff
To evaluate and compare the perceived autonomy of people using wheeled mobility assistive devices (WMADs) in five community-based environments. To evaluate how personal, environmental, and assistiv...

15 February 2024 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
SLSaud Lingawi
Saud Lingawi
JHJacob Hutton
Jacob Hutton
MKMahsa Khalili
Mahsa Khalili
BSBabak Shadgan
Babak Shadgan
JCJim Christenson
Jim Christenson
CKCalvin Kuo
Calvin Kuo