Christina Hoffmann

Dr. Christina Hoffmann

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2022 in Respiratory Research
Verified
Journal Article
Open access
PDF file
CHChristina Hoffmann
Christina Hoffmann
MMMariam Maglakelidze
Mariam Maglakelidze
ESErika von Schneidemesser
Erika von Schneidemesser
CWChristian Witt
Christian Witt
PHPeter Hoffmann
Peter Hoffmann
TBTim Butler
Tim Butler
Background: Ambient air pollution poses a major risk for the development and aggravation of respiratory diseases. Evidence suggests that even in low-level air pollution environments there is a risk for an increase in adverse respiratory symptoms. We examined whether variations in daily air pollution levels of nitrogen dioxide, ozone, or particulate matter in Berlin, Germany were associated with hospital admissions of chronic obstructive pulmonary disease (COPD) and asthma patients in a time series analysis. Methods: We calculated single and multi-pollutant models, investigated possible lags in effect, and analysed the influence of meteorological variables on the results. Data from January 2005 through December 2015 were used to quantify the concentration–response. Results: The risk ratio for asthma patients to be hospitalised on the same day of NO2 exposure was 1.101 per 10 µg/m3 NO2 increase (95% CI: 1.013 to 1.195), for COPD patients 1.123 (95% CI: 1.081 to 1.168). Neither the exposure to ozone (95% CI: 0.904 to 1.020), PM10 (95% CI: 0.990 to 1.127), nor PM2.5 (95% CI: 0.981 to 1.148) was associated with an increased risk ratio for asthma patients to be hospitalised. Risk ratios for the hospital admission of COPD patients were also not increased due to ozone (95% CI: 0.981 to 1.033), PM10 (95% CI: 0.988 to 1.032), or PM2.5 (95% CI: 0.966 to 1.019) exposure. The presented risk ratios and confidence intervals relate to the day of exposure. We found no increased hospitalisation risks with a delayed occurrence on subsequent days. Conclusions: A quantifiable, statistically significant increase in risk for asthma and COPD exacerbations owing to NO2 exposure at levels well below European regulatory limit values was observed.

26 August 2020 in BMC Public Health
Verified
Journal Article
Open access
PDF file
BLBenedikt Lenzer
Benedikt Lenzer
MRManuel Rupprecht
Manuel Rupprecht
CHChristina Hoffmann
Christina Hoffmann
PHPeter Hoffmann
Peter Hoffmann
ULUta Liebers
Uta Liebers
Background: In the face of climate change, the protection of vulnerable patients from extreme climatic conditions is of growing interest to the healthcare sector and governments. Inpatients are especially susceptible to heat due to acute illness and/or chronic diseases. Their condition can be aggravated by adverse environmental factors. Installing air conditioning can be seen as an element of public health adaptation because it was shown to improve mortality rates of hospital patients experiencing hot temperatures. Still, the mediating factors and resulting health effects are largely unknown. Method: The PRISMA-ScR guideline was followed for this scoping review. Available evidence on the health effects of Heating, Ventilation, Air Conditioning (HVAC) and fans was searched in Medline, Embase and the Cochrane Library. The focus of the search strategy was on inpatients of the hospital. Grey literature was screened on 14 relevant websites. English and German publications were eligible without restrictions on publication date. Results were charted according to the categories population, intervention, control and outcome together with a qualitative description. Results: The review process yielded eleven publications of which seven were issued after 2003. Seven were clinical trials, three cross-sectional studies and one was a case report. The publications described the installation of HVAC on general wards and in intensive care units. Main topics were heat stress protection and support of thermoregulation, but also the rewarming of hypothermic patients. HVAC use resulted in a recovery effect shown by improved vital signs, reduced cardiac stress, accelerated recuperation and greater physical activity. This protective effect was demonstrated by a shorter hospital stay for patients with respiratory disease and a reduction of mortality for heat illness patients. Conclusion: This scoping review summarises the fragmented evidence on health effects of HVAC and fan utilisation for inpatients. Installing HVAC has the potential to improve patients’ outcomes and to make hospital treatment more efficient during heat waves. The application of HVAC could be a promising adaptation measure to mitigate the adverse effects of climate change on health and healthcare systems.

1 October 2018 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
CHChristina Hoffmann
Christina Hoffmann
MHMarc Hanisch
Marc Hanisch
JHJana B. Heinsohn
Jana B. Heinsohn
VDVanessa Dostal
Vanessa Dostal
MJMelissa Jehn
Melissa Jehn
CWChristian Witt
Christian Witt
Purpose: Patients with COPD show an increase in acute exacerbations (AECOPD) during the cold season as well as during heat waves in the summer months. Due to global climate changes, extreme weather conditions are likely to occur more frequently in the future. The goal of this study was to identify patient groups most at risk of exacerbations during the four seasons of the year and to determine at which temperature threshold the daily hospital admissions due to AECOPD increase during the summer. Patients and methods: We analyzed retrospective demographic and medical data of 990 patients, who were hospitalized for AECOPD in Berlin, Germany. The cases were grouped into the following cohorts: “spring” (admission between March and May), “summer” (June – August), “autumn” (September – November), and “winter” (December – February). AECOPD hospital admissions from 2006 and 2010 were grouped into a “hot summer” cohort and cases from 2011 and 2012 into a “cold summer” data-set. Climate data were obtained from the German Meteorological Office. Results: Patients hospitalized for a COPD exacerbation during winter were significantly older than summertime patients (P=0.040) and also thinner than patients exacerbating in spring (P=0.042). COPD exacerbations during hot summer periods happened more often to patients with a history of myocardial infarction (P=0.014) or active smokers (P=0.011). An AECOPD during colder summers occurred in patients with a higher Charlson index, who suffered in increased numbers from peripheral vascular diseases (P=0.016) or tumors (P=0.004). Summertime hospital admissions increased above a daily minimum temperature of 18.3°C (P=0.006). Conclusion: The identification of COPD patient groups most at risk for climate related exacerbations enables climate-adapted prevention through patient guidance and treatment. In view of global climate changes, discovering vulnerabilities and implementing adaptive measures will be of growing importance.

17 May 2011 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
MZMathias Zimmermann
Mathias Zimmermann
MCMalte Cremer
Malte Cremer
CHChristina Hoffmann
Christina Hoffmann
KWKarin Weimann
Karin Weimann
AWAndreas Weimann
Andreas Weimann
Background: When certain inflammatory processes occur, toxic granulation neutrophils (TGNs) appear in the blood showing prominent cytoplasmic granules. Currently, the granularity of TGNs is analyzed by manual microscopy of blood smears. The SYSMEX XE-5000 is an automated hematology analyzer, which can measure toxic granulation of TGNs by calculating the Granularity (GI) Index. In this study we investigated if the GI-Index is suitable as a parameter for the TGN granularity in inflammatory diseases. Methods: An evaluation of the toxic granulation neutrophil (TGN) granularity by manual microscopy, the GI-Index and the C-reactive protein (CRP) concentrations of 158 patients were determined. Blood samples from 40 healthy individuals were incubated with lipopolysaccharide (LPS) for in vitro kinetic measurements of the GI-Index. Furthermore, time course measurements of the GI-Index and CRP concentrations of 100 intensive care unit patients were performed. Results: The GI-Index correlated with the microscopic rating of TGNs (n=158; rs=0.839; p<0.0001). When incubating the blood samples with LPS, the neutrophils displayed hypogranulation 30 min after incubation and a hypergranulation after 90 min. In vivo, the GI-Index indicated changes of the bacterial infection status 1 day earlier than the CRP concentration. The correlation of CRP and GI-Index varied between the patient cohorts (n=158; rs=0.836) (n=100; r=0.177), depending on the cause and extent of inflammation. Conclusions: The GI-Index is suited to quantify the granularity of TGNs. The GI-Index is an automated, standardized parameter available on a 24 h basis. We suggest that it replace the time-consuming, subjective and semiquantitative microscopic procedure.

21 December 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
MHMarco Hoffmann
Marco Hoffmann
SGSven Gerlach
Sven Gerlach
CHChristina Hoffmann
Christina Hoffmann
NRNathalie Richter
Nathalie Richter
NHNils Hersch
Nils Hersch
BHBernd Hoffmann
Bernd Hoffmann
Efficient and reliable transfer of nucleic acids for therapy applications is a major challenge. Stabilization of lipo- and polyplexes has already been successfully achieved by PEGylation. This modification reduces the interaction with serum proteins and thus prevents the lipoplexes from being cleared by the reticuloendothelial system. Problematically, this stabilization of lipoplexes simultaneously leads to reduced transfer efficiencies compared to non-PEGylated complexes. However, this reduction in transfer efficiency can be used to advantage since additional modification of PEGylated lipoplexes with functional groups enables improved selective transfer into target cells. Cancer cells overexpress folate receptors because of a significantly increased need of folate due to high cell proliferation rates. Thus, additional folate functionalization of PEGylated lipoplexes improves uptake into cancer cells. We demonstrate herein that NHS coupling chemistries can be used to modify two commercially available transfection reagents (Fuse-It-DNA and Lipofectamine® 3000) with NHS-PEG-folate for increased uptake of nucleic acids into cancer cells. Lipoplex characterization and functional analysis in cultures of cancer- and healthy cells clearly demonstrate that functionalization of PEGylated lipoplexes offers a promising method to generate efficient, stable and selective nucleic acid transfer systems.

20 December 2022 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
CWChristian Witt
Christian Witt
CKCamilla Kienast
Camilla Kienast
GBGeorg Bölke
Georg Bölke
CHChristina Hoffmann
Christina Hoffmann
RRRobert Roehle
Robert Roehle
ULUta Liebers
Uta Liebers
BackgroundGunshot emissions contain toxic elements that can harm those frequently exposed, such as police officers. Several years ago, police indoor firing ranges were closed by the Berlin municipality in response to police officer health complaints, and an investigation was launched into the possible respiratory health risks of frequent gunshot emission exposure. We, therefore, conducted an exploratory cross-sectional study to investigate clinical and functional parameters of respiratory health as well as the burden of trace elements in policemen with long-term high exposure to indoor gunshot emissions, compared to low-exposure and control groups. MethodsWe conducted lung function tests and collected blood and urine samples from Berlin police officers and government employees who were divided into three subject groups based on exposure to gunshot emissions: high exposure (n = 53), low exposure (n = 94) and no exposure (n = 76). Lung function was examined using body plethysmography. Blood and urine samples were tested via inductively coupled plasma mass spectrometry for the presence of common gunshot powder elements (antimony, lead and manganese). Exposure and symptoms were assessed using records as well as questionnaires. ResultsHigher exposure was associated with more respiratory symptoms during gun shooting practice (64% vs. 21%, P < 0.001) compared to the low-exposure group. Headache, cough, discoloured mucous and shortness of breath were also more common as were some other symptoms. The cough symptomatology of the high-exposure group also persisted significantly longer (median: 0.67 vs. 0.01 days, range: 0 to 5 days, P = 0.029) compared to the low-exposure group. They also showed a lower forced expiratory volume in 1 s/forced vital capacity quotient (Tiffeneau index), P = 0.018 between the three groups and P = 0.005 for the high-exposure group, a possible marker of early, subclinical bronchial obstruction. We observed increased blood lead concentrations depending on subject's age (+1.2% per year, 95% confidence interval: 0.5-1.9%, P < 0.001) and cumulative gunshot exposure (+0.34% per 100 000 shots, 0.02-0.66%, P = 0.037). ConclusionsThese first results suggest that long-term exposure to indoor gunshot emissions induces bronchitic reactions due to repeated irritation of the airways. Higher levels of exposure lead to more negatively impacted lung function and higher blood lead levels with the possible reason that more frequent exposure may mean shorter regeneration phases for the respiratory mucous membrane. We recommend a reduction of exposure to gunshot emissions in order to decrease symptoms and avoid any-even small-deterioration in spirometry.