Paul Adam Olszynski

Dr. Paul Adam Olszynski

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2020 in Journal of Ultrasound in Medicine
Verified
Journal Article
Open access
PDF file
IMIrene W. Y. Ma
Irene W. Y. Ma
PSPeter Steinmetz
Peter Steinmetz
KWKirstin Weerdenburg
Kirstin Weerdenburg
MWMichael Y. Woo
Michael Y. Woo
POPaul Adam Olszynski
Paul Adam Olszynski
PTPete Tonseth
Pete Tonseth
Objectives: This study sought to establish by expert review a consensus‐based, focused ultrasound curriculum, consisting of a foundational set of focused ultrasound skills that all Canadian medical students would be expected to attain at the end of the medical school program.Methods: An expert panel of 21 point‐of‐care ultrasound and educational leaders representing 15 of 17 (88%) Canadian medical schools was formed and participated in a modified Delphi consensus method. Experts anonymously rated 195 curricular elements on their appropriateness to include in a medical school curriculum using a 5‐point Likert scale. The group defined consensus as 70% or more experts agreeing to include or exclude an element. We determined a priori that no more than 3 rounds of voting would be performed.Results: Of the 195 curricular elements considered in the first round of voting, the group reached consensus to include 78 and exclude 24. In the second round, consensus was reached to include 4 and exclude 63 elements. In our final round, with 1 additional item added to the survey, the group reached consensus to include an additional 3 and exclude 8 elements. A total of 85 curricular elements reached consensus to be included, with 95 to be excluded. Sixteen elements did not reach consensus to be included or excluded.Conclusions: By expert opinion‐based consensus, the Canadian Ultrasound Consensus for Undergraduate Medical Education Group recommends that 85 curricular elements be considered for inclusion for teaching in the Canadian medical school focused ultrasound curricula.

9 April 2020 in Canadian Journal of Emergency Medicine
Verified
Journal Article
Open access
PDF file
DKDaniel J Kim
Daniel J Kim
TJTomislav Jelic
Tomislav Jelic
MWMichael Y. Woo
Michael Y. Woo
CHClaire Heslop
Claire Heslop
POPaul Adam Olszynski
Paul Adam Olszynski
The World Health Organization declared the novel coronavirus disease 2019 (COVID-19) to be a pandemic on March 11, 2020, and, currently, there are over 10,000 confirmed cases in Canada, with this number expected to grow exponentially. There has been widespread interest in the use of point-of-care ultrasound (POCUS) in the management of patients with suspected COVID-19. The CAEP Emergency Ultrasound Committee has developed recommendations on the use of POCUS in these patients, with an emphasis on machine infection control measures.

19 June 2017 in Canadian Journal of Emergency Medicine
Verified
Journal Article
Closed access
PDF file
POPaul Adam Olszynski
Paul Adam Olszynski
DKDaniel J Kim
Daniel J Kim
JCJordan Chenkin
Jordan Chenkin
LRLouise Rang
Louise Rang
Emergency ultrasound (EUS) is now widely considered to be a “skill integral to the practice of emergency medicine.”1The Canadian Association of Emergency Physicians (CAEP) initially issued a position statement in 1999 supporting the availability of focused ultrasound 24 hours per day in the emergency department (ED).2

3 January 2022 in The Ultrasound Journal
Verified
Journal Article
Open access
PDF file
POPaul Adam Olszynski
Paul Adam Olszynski
RMRory A. Marshall
Rory A. Marshall
TOT. Dylan Olver
T. Dylan Olver
TOTrevor Oleniuk
Trevor Oleniuk
CACameron Auser
Cameron Auser
RWRob Woods
Rob Woods
Background: While intra-arrest echocardiography can be used to guide and monitor chest compression quality, it is not currently feasible on the scene of out-of-hospital cardiac arrests. Rapid and automated sonographic localization of the heart may provide first-responders guidance to an optimal area of compression without requiring them to interpret ultrasound images. In this proof-of-concept porcine study, we sought to describe the performance of an automated ultrasound device in correctly identifying and tracing the borders of the heart in three distinct states: pre-arrest, arrest, and late arrest. Methods: An automated ultrasound device (bladder scanner) was placed on the chests of 7 swine, along the left sternal border (4th–8th intercostal spaces). Scanner-generated images were recorded for each space during pre-arrest, arrest, and finally late arrest. 828 images of the LV and LV outflow tract were randomized and 150 (50/state) selected for analysis. Scanner tracings of the heart were then digitally obscured to facilitate tracing by expert reviewers who were blinded to the physiologic state. Reviewer tracings were compared to bladder scanner tracings; with concordance between these images determined via Sørensen–Dice index (SDI). Results: When compared to human reviewers, the bladder scanner was able to identify and trace the borders during cardiac arrest. The bladder scanner performed best at the time of arrest (SDI 0.900 ± 0.059). As resuscitation efforts continued and time from initial arrest increased, the scanner’s performance decreased dramatically (SDI 0.597 ± 0.241 in late arrest). Conclusion: An automated ultrasound device (bladder scanner) reliably traced porcine hearts during cardiac arrest. It is possible a device could be developed to indicate where compressions should be performed without requiring the operator to interpret ultrasound images. Further investigation into rapid, automated, sonographic localization of the heart to identify the area of compression in out-of-hospital cardiac arrest is warranted.

24 February 2018 in Journal of Ultrasound in Medicine
Verified
Journal Article
Closed access
PDF file
POPaul Adam Olszynski
Paul Adam Olszynski
JAJordan Anderson
Jordan Anderson
KTKrista Trinder
Krista Trinder
TDTrustin Domes
Trustin Domes

19 March 2018 in Canadian Journal of Emergency Medicine
Verified
Journal Article
Closed access
PDF file
POPaul Adam Olszynski
Paul Adam Olszynski
DKDaniel J Kim
Daniel J Kim
JCJordan Chenkin
Jordan Chenkin
LRLouise Rang
Louise Rang
MGmembers of the CAEP Emergency Ultrasound Committee curriculum working group
members of the CAEP Emergency Ultrasound Committee curriculum working group