Jia-Kun Chen

Dr. Jia-Kun Chen

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2007 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
JCJia-Kun Chen
Jia-Kun Chen
Ruey-Jen YangRuey-Jen Yang
Ruey-Jen Yang

1 December 2021 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
CCChung-Yen Chen
Chung-Yen Chen
PCPing-Hui Chen
Ping-Hui Chen
JCJia-Kun Chen
Jia-Kun Chen
TSTa-Chen Su
Ta-Chen Su

13 February 2023 in Environmental Research
Verified
Journal Article
Open access
YCYen-Ching Chen
Yen-Ching Chen
PHPei-Iun Hsieh
Pei-Iun Hsieh
JCJia-Kun Chen
Jia-Kun Chen
EKEmily Kuo
Emily Kuo
HYHwa-Lung Yu
Hwa-Lung Yu
JCJen-Hau Chen
Jen-Hau Chen
How indoor air quality affects the temporal associations of long-term exposure to low-level air pollutants with cognition remains unclear. This cohort study (2011-2019) included 517 non-demented older adults at baseline with four repeated cognitive assessments. The time-varying exposure to PM2.5, PM10, NO2, SO2, CO, and O3 was estimated for each participant from 1994 to 2019. Indoor air quality was determined by ventilation status and daily indoor time. Generalized linear mixed models were used to analyze the association of air pollutants, indoor air quality, and cognition adjusting for important covariates. Over time, per 2.97 μg/m3 (i.e., an interquartile range) increment of PM2.5 was associated with the poor performance of memory (Z score of a cognitive test, βˆ:-0.14), attention (βˆ:-0.13), and executive function (βˆ:-0.20). Similarly, per 2.05 μg/m3 increase in PM2.5-10 was associated with poor global cognition [adjusted odds ratio (aOR): 1.48, βˆ:-0.28], attention (βˆ:-0.07), and verbal fluency (βˆ:-0.09); per 4.94 μg/m3 increase in PM10 was associated with poor global cognition (aOR: 1.78; βˆ:-0.37). In contrast, per 2.74 ppb increase in O3 was associated with better global cognition (βˆ:0.36 to 0.47). These associations became more evident in participants with poor ventilation or short daily indoor time (<12.5 h/day). For global cognition, the exposure to a 10-μg/m3 increment in PM2.5, PM2.5-10, and PM10 corresponded to 1.4, 5.8, and 2.8 years of aging, respectively. This study demonstrated how indoor air quality in areas using clean fuels differentially affected the associations of long-term exposure to low-level air pollutants with cognition. Tightening air quality standards may help prevent dementia.

1 June 2010 in Environmental Engineering Science
Verified
Journal Article
Closed access
RHRong Fung Huang
Rong Fung Huang
YNYou-Cyun Nian
You-Cyun Nian
JCJia-Kun Chen
Jia-Kun Chen
Flow and spillage characteristics of conventional and air-curtain range hoods under static condition were experimentally studied, and their differences in physical mechanisms were compared. Two oil pans containing hot oils heated to 230°C by electric heaters were placed on a countertop to simulate the cooking condition. Large amount of oil fumes were generated and rose from the oil pans. Flow features were examined using laser-light-sheet-assisted oil fume flow visualization method. Local-averaged spillages of tracer gas (sulfur hexafluoride) in the front and lateral planes of the range hoods were detected by employing the tracer-gas concentration detection technique. For the conventional range hood, the flow visualization showed two most probable locations for spillages: the region near the front edge of countertop due to the boundary-layer separation and the region around the lower edge of the hood side panels due to the expansion effect of hot plumes. Detected local-averaged tracer-gas concentrations around these two locations correlated well with the results of flow visualizations. No significant spillages of oil fumes or tracer-gas concentration was observed or detected around the front and lateral planes of the air-curtain range hood. Around the front edge of countertop, the detected tracer-gas concentration of the conventional range hood was larger than that of the air-curtain range hood by about three orders of magnitude. Overall, the air-curtain range hood presented drastically smaller spillages than the conventional range hood.

25 November 2022 in Journal of the Formosan Medical Association
Verified
Journal Article
Open access
CCChung-Yen Chen
Chung-Yen Chen
PCPing-Hui Chen
Ping-Hui Chen
JCJia-Kun Chen
Jia-Kun Chen
TSTa-Chen Su
Ta-Chen Su
This mini-review provides the practice guideline recommendations for ventilation of remodeled negative-pressure isolation wards for COVID-19 Patients. Remodeled “quasi-negative-pressure” isolation wards had been proved a feasible, inexpensive, safe, and effective measure to contain nosocomial outbreaks. We should first determine the minimum required ventilation volume of an isolation ward based on the severity of COVID-19 patients. Mechanical ventilation remains the mainstay for achieving the requirement, while the assistance of recirculation is also helpful. Beyond adequate ventilation volume, the “clean to less-clean” directional airflow remains the golden rule for the solution of indoor ventilation. The virus-laden exhaust should be treated with HEPA/UV device or be kept away from living organisms, buildings, and air inlets.

1 October 2006 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
JCJia-Kun Chen
Jia-Kun Chen
WLWin-Jet Luo
Win-Jet Luo
Ruey-Jen YangRuey-Jen Yang
Ruey-Jen Yang
The purpose of this study is to investigate electroosmotic flows driven by externally applied DC and AC electric fields in curved microchannels. For the DC electric driving field, the velocity distribution and secondary flow patterns are investigated in microchannels with various curvature ratios. We use the Dean number to describe the curvature effect of the flow field in DC electric field. The result implies that the effect of curvatures and the strength of the secondary flows become get stronger when the curvature ratio of C/A (where C is the radius of curvature of the microchannel and A is the half-height of rectangular curved tube.) is smaller. For the AC electric field, the velocity distribution and secondary flow patterns are investigated for driving frequencies in the range of 2.0 kHz (Wo=0.71) to 11 kHz (Wo=1.66). The numerical results reveal that the velocity at the center of the microchannel becomes lower at higher frequencies of the AC electric field and the strength of the secondary flow decreases. When the applied frequency exceeds 3.0 kHz (Wo=0.87), vortices are no longer observed at the corners of the microchannel. Therefore, it can be concluded that the secondary flow induced at higher AC electric field frequencies has virtually no effect on the axial flow field in the microchannel.