Purpose: The purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG) not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol. Patients and methods: Of 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy. Results: At the month 12 visit, 94.7% of eyes (89/94) in the stent group reported an unmedicated intraocular pressure (IOP) reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98) in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02) at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94) in the iStent inject group and 89.8% of eyes (88/98) in the medical therapy group. Mean (standard deviation) IOP decreases from screening of 8.1 (2.6) mmHg and 7.3 (2.2) mmHg were reported in the iStent inject and medical therapy groups, respectively. A high safety profile was also noted in this study in both the iStent inject and medical therapy groups, as measured by stable best corrected visual acuity, cup-to-disc ratio, and adverse events. Conclusion: These data show that the use of iStent inject is at least as effective as two medications, with the clinical benefit of reducing medication burden and assuring continuous treatment with full compliance to implant therapy as well as having a highly favorable safety profile.
1 December 2008 in Journal of Cataract & Refractive Surgery
To evaluate the optical and visual performance after implantation of refractive or apodized diffractive multifocal intraocular lenses (IOLs). Military Health Service Institute, Warsaw, Poland. Uncorrected distance visual acuity, best distance-corrected visual acuity, best distance-corrected near visual acuity, distance contrast sensitivity under photopic conditions (CSV-1000), residual refractive error, and wavefront aberrations (LADARWave Hartmann-Shack wavefront analyzer) were measured in 23 patients who had bilateral implantation of the AcrySof ReSTOR SN60D3 IOL and 23 patients who had bilateral implantation of the ReZoom IOL.... At the 6-month postoperative visit, the mean photopic uncorrected distance acuity was 0.03+/-0.05 (SD) in the ReSTOR group and 0.02+/-0.06 logMAR in the ReZoom group (both approximately 20/20) (P= .569). In all patients, the mean photopic best distance-corrected acuity was 0.00 logMAR (approximately 20/20) and the mean photopic best distance-corrected near acuity at 35 cm was 0.10 logMAR. The photopic contrast sensitivity was within the standard normal range in both IOL groups. The difference in photopic contrast sensitivity between groups was statistically significant (P<.001). Higher-order aberrations, in particular coma and spherical aberrations, were significantly higher in the ReZoom group (all P<.001). AcrySof ReSTOR SN60D3 and ReZoom IOLs provided good visual performance at distance and near under photopic conditions. Optical quality measures were significantly worse in patients with ReZoom IOLs.
1 October 2009 in Journal of Cataract & Refractive Surgery
To compare phacoemulsification parameters of torsional and longitudinal ultrasound modes. Ophthalmology Department, Military Health Service Institute, Warsaw, Poland. This prospective study evaluated eyes 1, 7, and 30 days after phacoemulsification with an Infiniti Vision System using the torsional or longitudinal ultrasound (US) mode. Cataract classification was according to the Lens Opacities Classification System II. Nucleus fragmentation was by the phaco-chop and quick-chop methods. Primary outcome measures were phaco time, mean phaco power, mean torsional amplitude, and aspiration time. Total energy, defined as cumulative dissipated energy (CDE) x aspiration time, and the effective coefficient, defined as aspiration time/phaco time, were also calculated. Four hundred eyes were evaluated. The CDE was statistically significantly lower in the torsional mode for nucleus grades I, II, and III (P<.001) but not for grade IV (P>.05). Aspiration time was statistically significantly shorter in the torsional mode than in the longitudinal mode for nucleus grades III and IV (P<.05). Total energy was significantly lower in the torsional mode for all nucleus densities (P<.05). The effective coefficient was significantly lower in the longitudinal mode except for nucleus grade I (P<.05). Torsional phacoemulsification was more effective than longitudinal phacoemulsification in the amount of applied fluid and the quantity of US energy expended. With the torsional method, it was possible to maintain a constant ratio of amount of fluid flow to quantity of US energy used, regardless of nucleus density.
1 October 2018 in American Journal of Ophthalmology
Purpose: To assess tolerability and efficacy following a switch from benzalkonium chloride–latanoprost to preservative-free latanoprost in patients with glaucoma or ocular hypertension. Methods: A total of 140 patients with glaucoma or ocular hypertension controlled with benzalkonium chloride-latanoprost for at least 3 months were switched to treatment with preservative-free latanoprost. Assessments were made on days 15, 45, and 90 (D15, D45, and D90) and included best-corrected visual acuity, intraocular pressure, slit lamp examination, fluorescein staining, tear film break-up time, patient symptom evaluation, and subjective estimation of tolerability. Results: Mean best-corrected visual acuity remained unchanged during the study. Mean intraocular pressure compared with baseline (D0) remained stable throughout the study (D0, 15.9 mmHg (standard deviation = 2.6); D90, 15.3 mmHg (standard deviation = 2.4); p < 0.006). Tear film break-up time improved or remained unchanged relative to baseline in 92% of patients at D45 and in 93% at D90. Moderate-to-severe conjunctival hyperemia was seen in 56.8% of patients at D0, but this figure decreased to 13.7%, 2.2%, and 1.6% at D15, D45, and D90, respectively. Subjective assessment of tolerability (0–10 scale) indicated improvement with change of therapy (mean score: 5.3 (standard deviation = 2.2) at D0 versus 1.9 (standard deviation = 1.7) at D90; p < 0.0001). Conclusion: Preservative-free latanoprost has at least the same intraocular pressure-lowering efficacy as benzalkonium chloride–latanoprost, with a better tolerability profile. This may translate into greater control of treatment and improved quality of life.