Makoto Tsunoda

Dr. Makoto Tsunoda

University of Tokyo
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2006 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MTMakoto Tsunoda
Makoto Tsunoda

1 August 2014 in Journal of Chromatography B
Verified
Journal Article
Closed access
MIMuneki Isokawa
Muneki Isokawa
TKTakahiro Kanamori
Takahiro Kanamori
TFTakashi Funatsu
Takashi Funatsu
MTMakoto Tsunoda
Makoto Tsunoda

1 January 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
YSYanting Song
Yanting Song
CXChang Xu
Chang Xu
HKHiroshi Kuroki
Hiroshi Kuroki
YLYiyi Liao
Yiyi Liao
MTMakoto Tsunoda
Makoto Tsunoda

24 May 2013 in The Analyst
Verified
Journal Article
Open access
PDF file
MIMuneki Isokawa
Muneki Isokawa
TFTakashi Funatsu
Takashi Funatsu
MTMakoto Tsunoda
Makoto Tsunoda
A method for analyzing biothiols based on high-performance liquid chromatography (HPLC)-fluorescence detection under hydrophilic interaction chromatography (HILIC) conditions has been developed. Thiols were derivatized with nonfluorescent ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F), which selectively reacts with the thiol groups to furnish the corresponding fluorescent SBD–thiols. Among the six different kinds of HILIC columns examined, the ZIC-HILIC column with sulfobetaine groups in the stationary phase proved to be the best for the separation of SBD–thiols. Eight thiols—N-acetylcysteine, cysteamine, homocysteine, cysteine, cysteinylglycine, glutathione, γ-glutamylcysteine, and internal standard N-(2-mercaptopropionyl)glycine—were baseline-separated within 10 min. The detection sensitivity was improved partly due to the increase in the SBD–thiol fluorescence owing to the acetonitrile-rich mobile phase used. The detection limits at a signal-to-noise ratio of 3 were 0.02–3.4 nmol l−1. The method could successfully quantify six thiols in a human plasma sample, while cysteamine could not be detected. Both the intra- and interday precisions were below 4% for homocysteine, cysteine, cysteinylglycine, glutathione, and γ-glutamylcysteine except for N-acetylcysteine. This method should be a useful tool for investigating the relationship between sulfur metabolism and related diseases, since a multicomponent system consisting of different thiol compounds could be analyzed simultaneously with high sensitivity within a short time.

21 January 2010 in Analytical Chemistry
Verified
Journal Article
Closed access
CAChiaki Aoyama
Chiaki Aoyama
ASAkira Saeki
Akira Saeki
MNMasao Noguchi
Masao Noguchi
YSYoshitaka Shirasaki
Yoshitaka Shirasaki
SSShuichi Shoji
Shuichi Shoji
MTMakoto Tsunoda
Makoto Tsunoda

1 March 2015 in Journal of Chromatography B
Verified
Journal Article
Closed access
TKTakahiro Kanamori
Takahiro Kanamori
MIMuneki Isokawa
Muneki Isokawa
TFTakashi Funatsu
Takashi Funatsu
MTMakoto Tsunoda
Makoto Tsunoda