Benedikt Bernhard

Dr. Benedikt Bernhard

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2023 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
LALouhai Alwan
Louhai Alwan
DBDominik C. Benz
Dominik C. Benz
SCSarah A.M. Cuddy
Sarah A.M. Cuddy
SDStephan Dobner
Stephan Dobner
ISIsaac Shiri
Isaac Shiri
CGChristoph Gräni
Christoph Gräni

6 April 2022 in JACC: Basic To Translational Science
Verified
Journal Article
Open access
JIJoël Illi
Joël Illi
BBBenedikt Bernhard
Benedikt Bernhard
CNChristopher Nguyen
Christopher Nguyen
TPThomas Pilgrim
Thomas Pilgrim
FPFabien Praz
Fabien Praz
CGChristoph Gräni
Christoph Gräni
• 3D printed patient specific phantoms can visualize complex cardiovascular anatomy • Common imaging modalities for 3D printing are CCT and CMR • Material jetting/PolyJet and stereolithography are widely used printing techniques • Standardized validation is warranted to compare different 3D printing technologies

31 January 2022 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Open access
BBBenedikt Bernhard
Benedikt Bernhard
HGHanna Grogg
Hanna Grogg
JZJan Zurkirchen
Jan Zurkirchen
CDCaglayan Demirel
Caglayan Demirel
DHDaniel Hagemeyer
Daniel Hagemeyer
CGChristoph Gräni
Christoph Gräni
Myocardial strain is an established parameter for the assessment of cardiac function and routinely derived from speckle tracking echocardiography (STE). Novel post-processing tools allow deformation imaging also by 4D cardiac computed tomography angiography (CCT). This retrospective study aims to analyze the reproducibility of CCT strain and compare it to that of STE. Left (LV) and right ventricular (RV), and left atrial (LA) ejection fraction (EF), dimensions, global longitudinal (GLS), circumferential (GCS) and radial strain (GRS) were determined by STE and CCT feature tracking in consecutive patients with severe aortic stenosis evaluated for transcatheter aortic valve implantation. 106 patients (mean age 79.9 ​± ​7.8, 44.3% females) underwent CCT at a median of 3 days (IQR 0-28 days) after STE. In CCT, strain measures showed good to excellent reproducibility (intra- and inter-reader intraclass correlation coefficient ≥0.75) consistently in the LV, RV and LA. In STE, only LV GLS and LA GLS yielded good reproducibility, whereas LV GCS and LV GRS showed moderate, and RV GLS and free wall longitudinal strain (FWLS) poor reproducibility. Agreement between CCT and STE was strong for LV GLS only, while other strain features displayed moderate (LV GCS, LA GLS) or weak (LV GRS, RV GLS and FWLS) inter-modality correlation. LV, RV and LA CCT strain assessments were highly reproducible. While a strong agreement to STE was found for LV GLS, inter-modality correlation was moderate or weak for LV GCS, LV GRS, and RV and LA longitudinal strain, possibly related to poor reproducibility of STE measurements.

19 October 2022 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
BBBenedikt Bernhard
Benedikt Bernhard
ASAaron Schnyder
Aaron Schnyder
DGDavide Garachemani
Davide Garachemani
KFKady Fischer
Kady Fischer
GTGiulin Tanner
Giulin Tanner
CGChristoph Gräni
Christoph Gräni

30 September 2024 in JACC
Verified
Journal Article
Closed access
BBBenedikt Bernhard
Benedikt Bernhard
MMMartin E. Marxer
Martin E. Marxer
JZJan C. Zurkirchen
Jan C. Zurkirchen
JSJonathan Schütze
Jonathan Schütze
AWAndreas Wahl
Andreas Wahl
CGChristoph Gräni
Christoph Gräni

1 December 2023 in Radiology
Verified
Journal Article
Closed access
BBBenedikt Bernhard
Benedikt Bernhard
ZLZoe Leib
Zoe Leib
SDStephan Dobner
Stephan Dobner
CDCaglayan Demirel
Caglayan Demirel
Federico CaobelliFederico Caobelli
Federico Caobelli
CGChristoph Gräni
Christoph Gräni
Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.