Because of the limited number of Spanish validated questionnaires available to assess auditory functionality in daily life situations in adults, the purpose of this study was to investigate the val...
Hearing-impaired individuals experience higher levels of listening effort in challenging situations, affecting their communication in daily life. The purpose of this study was to linguistically and...
11 September 2017 in Cochlear Implants International
Objectives: To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI). Methods: Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on. Results: Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1–N1–P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness. Conclusion: Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.
14 July 2022 in International Journal of Audiology
This study aimed to evaluate the association between certain social determinants of health (i.e. educational level, income, and social support) and attitudes towards hearing loss and hearing aids a...
Background and Objectives: Otoacoustic emissions (OAEs) are low-intensity sounds generated by the cochlea and associated with the function of the outer hair cells. Since OAE measurements do not require active participation of a listener, OAEs are considered an objective measure of cochlear function. While distortion-product OAEs (DPOAEs) are commonly used in clinical practice, limited information is available on the performance of various clinical devices. This study compared two commercial clinical devices, Titan and Eclipse from Interacoustics, and collected normative data for DPOAEs in people with normal hearing. The data collection and analysis were focused on signal and noise amplitudes as well as signal-to-noise ratios (SNRs).Subjects and Methods: Sixty-three participants with normal hearing (age 23.2±2.0 years) were included in the study. DPOAEs were measured at 31 frequencies ranging from 500 to 10,000 Hz.Results: DPOAE amplitude differed across frequencies. Additionally, a high number of unreliable responses were observed at the edge frequencies (6,072 Hz). There were no significant differences between the two devices in terms of DPOAE amplitudes, but the recorded-noise levels (amplitude) differed significantly. SNRs of the recorded OAEs were frequency dependent (higher frequencies showed larger SNRs), and significant differences in terms of SNR were found between the two devices.Conclusions: Despite the above-mentioned differences, the OAEs recorded with both devices met the pass criteria for the SNR (≥6 dB) consistently across frequencies, and thus the differences do not compromise the test outcomes. The frequency dependence of the OAE amplitudes and the corresponding SNRs may be relevant for clinical practice.