Patricio Colmegna

Dr. Patricio Colmegna


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
JGJose Garcia-Tirado
Jose Garcia-Tirado
DLDayu Lv
Dayu Lv
JCJohn P. Corbett
John P. Corbett
PCPatricio Colmegna
Patricio Colmegna
MBMarc D. Breton
Marc D. Breton

20 November 2020 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
PDF file
JHJonathan Hughes
Jonathan Hughes
TGThibault Gautier
Thibault Gautier
PCPatricio Colmegna
Patricio Colmegna
CFChiara Fabris
Chiara Fabris
MBMarc D Breton
Marc D Breton
The capacity to replay data collected in real life by people with type 1 diabetes mellitus (T1DM) would lead to individualized (vs population) assessment of treatment strategies to control blood glucose and possibly true personalization. Patek et al introduced such a technique, relying on regularized deconvolution of a population glucose homeostasis model to estimate a residual additive signal and reproduce the experimental data; therefore, allowing the subject-specific replay of what-if scenarios by altering the model inputs (eg, insulin). This early method was shown to have a limited domain of validity. We propose and test in silico a similar approach and extend the method applicability. A subject-specific model personalization of insulin sensitivity and meal-absorption parameters is performed. The University of Virginia (UVa)/Padova T1DM simulator is used to generate experimental scenarios and test the ability of the methodology to accurately reproduce changes in glucose concentration to alteration in meal and insulin inputs. Method performance is assessed by comparing true (UVa/Padova simulator) and replayed glucose traces, using the mean absolute relative difference (MARD) and the Clarke error grid analysis (CEGA). Model personalization led to a 9.08 and 6.07 decrease in MARD over a prior published method of replaying altered insulin scenarios for basal and bolus changes, respectively. Replay simulations achieved high accuracy, with MARD <10% and more than 95% of readings falling in the CEGA A-B zones for a wide range of interventions. In silico studies demonstrate that the proposed method for replay simulation is numerically and clinically valid over broad changes in scenario inputs, indicating possible use in treatment optimization.

23 September 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
PCPatricio Colmegna
Patricio Colmegna
ABAlessandro Bisio
Alessandro Bisio
RMRyan McFadden
Ryan McFadden
CWChristian Wakeman
Christian Wakeman
MOMary Clancy Oliveri
Mary Clancy Oliveri
MBMarc Breton
Marc Breton
Objective: To develop and evaluate a novel Web-based Simulation Tool (WST) that brings simulation technologies to people with Type 1 Diabetes (T1D), enabling unique patient-data interactions seamlessly on a daily basis. Methods: A pilot clinical trial was conducted to assess system usability. The study consisted of one week of observation (Phase 1) and four weeks of interaction with WST (Phase 2). Responses to Technology Acceptance (TA) and Diabetes Distress Scale (DDS) questionnaires were collected, and follow-up interviews were conducted after Phase 2. Results: Fifteen participants with T1D using Control-IQ technology (age: 36 $\pm$ 13 years, HbA1c: 6.5% $\pm$ 0.7%) completed all study procedures. Generated simulation models achieved a median Mean Absolute Relative Difference (MARD) of 6.8% [interquartile range, IQR: 5.1%, 9.1%]. A decrease in expected benefits (likely explained by issues with the third-party data collection system) and an increase in expected burdens were observed. On a 1-5 scale, ease of use, trust, and usefulness scores were 3 [3,4], 4 [3,4], and 4 [3,4], respectively. Time below 70 mg/dL decreased between Phases 1 and 2 (1.6% [0.7%,3.7%] vs 0.8% [0.5%,3.0%]). A reduction in mean emotional burden was also observed (2.5 $\pm$ 1.1 vs 2.1 $\pm$ 0.8). Conclusions: Results indicate that there was a learning curve to WST, but also that most participants trusted the system and found it useful in their diabetes care. Significance: Simulation technologies like WST could be used by educators and patients to facilitate diabetes self-management, leading to better diabetes literacy and reducing associated distress.

1 October 2020 in Control Engineering Practice
Verified
Journal Article
Closed access
PCPatricio Colmegna
Patricio Colmegna
KWKe Wang
Ke Wang
JGJose Garcia-Tirado
Jose Garcia-Tirado
MBMarc D. Breton
Marc D. Breton

24 July 2019 in Journal of Diabetes Science and Technology
Verified
Journal Article
Open access
PDF file
EFEmilia Fushimi
Emilia Fushimi
PCPatricio Colmegna
Patricio Colmegna
Hernán De BattistaHernán De Battista
Hernán De Battista
FGFabricio Garelli
Fabricio Garelli
RSRicardo Sánchez-Peña
Ricardo Sánchez-Peña
Background: Either under standard basal-bolus treatment or hybrid closed-loop control, subjects with type 1 diabetes are required to count carbohydrates (CHOs). However, CHO counting is not only burdensome but also prone to errors. Recently, an artificial pancreas algorithm that does not require premeal insulin boluses—the so-called automatic regulation of glucose (ARG)—was introduced. In its first pilot clinical study, although the exact CHO counting was not required, subjects still needed to announce the meal time and classify the meal size. Method: An automatic switching signal generator (SSG) is proposed in this work to remove the manual mealtime announcement from the control strategy. The SSG is based on a Kalman filter and works with continuous glucose monitoring readings only. Results: The ARG algorithm with unannounced meals (ARGum) was tested in silico under the effect of different types of mixed meals and intrapatient variability, and contrasted with the ARG algorithm with announced meals (ARGam). Simulations reveal that, for slow-absorbing meals, the time in the euglycemic range, [70-180] mg/dL, increases using the unannounced strategy (ARGam: 78.1 [68.6-80.2]% (median [IQR]) and ARGum: 87.8 [84.5-90.6]%), while similar results were found with fast-absorbing meals (ARGam: 87.4 [86.0-88.9]% and ARGum: 87.6 [86.1-88.8]%). On the other hand, when intrapatient variability is considered, time in euglycemia is also comparable (ARGam: 81.4 [75.4-83.5]% and ARGum: 80.9 [77.0-85.1]%). Conclusion: In silico results indicate that it is feasible to perform an in vivo evaluation of the ARG algorithm with unannounced meals.

30 November 2020 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
PCPatricio Colmegna
Patricio Colmegna
FBFernando D. Bianchi
Fernando D. Bianchi
RSR. S. Sanchez-Pena
R. S. Sanchez-Pena
Keeping the blood glucose levels within the safe range during meals and exercise still represents a major hurdle not only for patients with type 1 diabetes (T1D), but also for Artificial Pancreas (AP) systems. One of the reasons a fully (autonomous) closed-loop solution has not been released onto the market yet is the slow action of current insulin analogs. To partially overcome this limitation, the authors have previously designed a switched control strategy equipped with an insulin-on-board (IOB) safety loop that mitigates meal-related glucose excursions without carbohydrate counting. In this paper, a similar strategy based on a () control law has been adapted to safely handle also exercise challenges with minimum user intervention. In silico results using the UVA/Padova simulator evidence that the proposed closed-loop scheme is feasible under moderate-intense exercise bouts by effectively and safely reducing the risk of hypoglycemia.