Rute Ferla

Ms. Rute Ferla

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2022 in Water
Verified
Journal Article
Open access
PDF file
Jorge MatosJorge Matos
Jorge Matos
Carolina Kuhn NovakoskiCarolina Kuhn Novakoski
Carolina Kuhn Novakoski
RFRute Ferla
Rute Ferla
MMMarcelo Giulian Marques
Marcelo Giulian Marques
MPMauricio Dai Prá
Mauricio Dai Prá
ETEder Daniel Teixeira
Eder Daniel Teixeira
Stepped spillways have been increasingly used to handle flood releases from large dams associated with hydropower plants, and it is important to evaluate the fluctuating pressure field on the steps. Hydraulic model investigations were conducted on three 53° (1V:0.75H) sloping and relatively large-stepped chutes to characterize the mean, fluctuating, and extreme pressures acting on the most critical regions of the step faces, near their outer edges. The pressure development along the chutes is presented, generally indicating an increase of the modulus of pressure coefficients up to the vicinity of the point of inception of air entrainment, and a decrease further downstream. The extreme pressure coefficients along the spillway are fitted by an empirical formula, and the critical conditions potentially leading to cavitation on prototypes are calculated. The correlation between the cavitation index and the friction factor is also applied for predicting the onset of cavitation on prototypes, and the results are compared with the pressure data-based method. Generally, the results obtained from those methods yield typical values for the cavitation index in the vicinity of the point of inception, varying approximately from 0.8 to 0.6, respectively. In light of these results, maximum unit discharges of about 15–20 m2/s are considered advisable on 53° sloping large-stepped spillways without artificial aeration, for step heights ranging from 0.6 to 1.2 m. For much higher unit discharges, a considerable reach of the spillway may potentially be prone to the risk of cavitation damage.

1 January 2021 in RBRH
Verified
Journal Article
Open access
PDF file
CRCarlo Lucca Coutinho Ungaretti Rossi
Carlo Lucca Coutinho Ungaretti Rossi
MMMarcelo Giulian Marques
Marcelo Giulian Marques
ETEder Daniel Teixeira
Eder Daniel Teixeira
JMJose Melo
Jose Melo
RFRute Ferla
Rute Ferla
MPMauricio Dai Prá
Mauricio Dai Prá
Simplified methods are useful alternatives for prior analysis of the effects of dam rupture and can guide the decision-making process for carrying out more complete studies. In this context, a new simplified approach is presented, which enables the analysis of aspects from dam rupture of earthen dams that failed due to overtopping, considering dam height and reservoir volume as input data. Hypothetical cases were analyzed applying dam-break hydrodynamic simulations, which results allowed the development of equations capable of estimating peak flow attenuation and peak discharge arrival time along the downstream valley. The proposed approach was applied in a hypothetical case study (15 m high dam and 17 hm3 reservoir volume), obtaining results close to those achieved through other methods, especially in case of estimating the maximum discharges throughout the downstream valley, where the average differences between the results of the methods were of the order of 15%.

1 January 2021 in RBRH
Verified
Journal Article
Open access
PDF file
RFRute Ferla
Rute Ferla
Carolina Kuhn NovakoskiCarolina Kuhn Novakoski
Carolina Kuhn Novakoski
PPPriscila dos Santos Priebe
Priscila dos Santos Priebe
MPMauricio Dai Prá
Mauricio Dai Prá
MMMarcelo Giulian Marques
Marcelo Giulian Marques
ETEder Daniel Teixeira
Eder Daniel Teixeira
The possibility of damage due to the phenomenon of cavitation leads the design of stepped spillways considering maximum specific discharges of 15 to 30 m2/s, a limit considerably lower than that practiced on smooth chutes. Aerators promote the insertion of air in the flow, allowing for the increase of specific flow rates. This work analyzes the pressures on the vertical faces of the steps and the air entrainment coefficient in the flow, through an experimental study in a physical model with a stepped chute angle of 53.13o, considering the installation of aerators in different places of the channel. Comparing the tested conditions with the natural aeration, it is concluded that the installation of the aerator does not change the magnitude of the minimum extreme hydrodynamic pressures, but anticipates the beginning of the flow aeration. A new equation is proposed to estimate the air entrainment coefficient, as well as a methodology for forecasting extreme pressures on the vertical faces of the steps, both valid in the range 3.0 ≤ Fr ≤ 6.0.

1 January 2021 in RBRH
Verified
Journal Article
Open access
PPPriscila dos Santos Priebe
Priscila dos Santos Priebe
RFRute Ferla
Rute Ferla
Carolina Kuhn NovakoskiCarolina Kuhn Novakoski
Carolina Kuhn Novakoski
AAAline Saupe Abreu
Aline Saupe Abreu
ETEder Daniel Teixeira
Eder Daniel Teixeira
MMMarcelo Giulian Marques
Marcelo Giulian Marques
The operation of stepped spillways is limited by a range of discharges due to the risk of occurrence of the cavitation phenomenon and erosion on its steps. Since there is a demand for spillways with the possibility of overflow of greater discharges, the designs seek to increase the air concentration of the flow, which can occur through the installation of piers in the spillway in order to protect the structure from the above mentioned damage. The aim of this work is to analyze flow characteristics and extreme minimum and maximum pressures with non-exceedance probability of 0.1% and 99.9% acting next to the step edges of the spillway with aeration induced by piers through an experimental analysis in a physical model. Based on the results obtained, flow behavior was defined and equations for predicting the extreme pressures that occur along the stepped spillway with aeration induced by piers were proposed.

1 January 2021 in RBRH
Verified
Journal Article
Open access
Carolina Kuhn NovakoskiCarolina Kuhn Novakoski
Carolina Kuhn Novakoski
RFRute Ferla
Rute Ferla
PPPriscila dos Santos Priebe
Priscila dos Santos Priebe
AAAline Saupe Abreu
Aline Saupe Abreu
MMMarcelo G. Marques
Marcelo G. Marques
ETEder D. Teixeira
Eder D. Teixeira
Stepped spillways can dissipate a great amount of energy during the flow passage over the chute, however these structures have limited operation due to the risk of cavitation damage. The induced aeration may protect the concrete chute through the air concentration near the channel bottom. Furthermore, some research studies have indicated that the presence of air in flows may reduce the mean pressures. The present research aims to analyze mean pressures, air entrainment coefficient and flow behavior over a stepped spillway with aeration induced by two different deflectors, comparing the results to natural aeration flow. Despite the jet impact influence, the induced aeration does not change significantly the mean pressures compared to natural aeration flow. The air entrainment coefficient, as well as the jet impact position, is higher for the deflector with the longer extension and, although air bubbles can be seen throughout the extension of the chute due to the air entrainment through the inferior flow surface, the induced aeration did not anticipate the boundary layer inception point position.

1 January 2020 in RBRH
Verified
Journal Article
Open access
PDF file
Carolina Kuhn NovakoskiCarolina Kuhn Novakoski
Carolina Kuhn Novakoski
RFRute Ferla
Rute Ferla
MPMauricio Dai Prá
Mauricio Dai Prá
ACAlba Valéria Brandão Canellas
Alba Valéria Brandão Canellas
MMMarcelo Giulian Marques
Marcelo Giulian Marques
ETEder Daniel Teixeira
Eder Daniel Teixeira
Stepped spillways aim to dissipate part of the upstream energy during the flow passage by the chute. However, the use of these structures is limited to a restrict range of specific discharges due to the risk of cavitation damage. As the air entrainment into the flow assists the concrete protection against the aforementioned damages, a possible solution by aerators installed along the chute, already disseminated to smooth chutes, is being studied to be used also in stepped spillways. The purpose of the present paper is to characterize a flow over a stepped chute with induced aeration by deflector and air supply by an airtight chamber trough tests conducted on a reduced scale physical model. The main regions observed during the tests are presented and were developed four equations that allow to approximately predict the location of the main regions for a given spillway.