Nils Jonas Ziegeler

Mr. Nils Jonas Ziegeler

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
NZNils Jonas Ziegeler
Nils Jonas Ziegeler
SSStefan Schweizer
Stefan Schweizer
SSStefan Schweizer
Stefan Schweizer
The determination of thermal structure functions from transient thermal measurements using network identification by deconvolution is a delicate process as it is sensitive to noise in the measured data. Great care must be taken not only during the measurement process but also to ensure a stable implementation of the algorithm. In this paper, a method is presented that quantifies the absolute accuracy of network identification on the basis of different test structures. For this purpose, three measures of accuracy are defined. By these metrics, several variants of network identification are optimized and compared against each other. Performance in the presence of noise is analyzed by adding Gaussian noise to the input data. In the cases tested, the use of a Bayesian deconvolution provided the best results.

7 February 2022 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
NZNils Jonas Ziegeler
Nils Jonas Ziegeler
SSStefan Schweizer
Stefan Schweizer
SSStefan Schweizer
Stefan Schweizer
In this work, an evaluation method for transient thermal measurements is presented. It allows for a high temporal sensitivity by analysing the spectral composition of a thermal transient, the so-called time constant spectrum. The spectral components provide a detailed insight into the heat flow dynamics and thermal parameters describing a multi-layer system. The method is based on a one-dimensional heat path analysis technique common for the thermal characterisation of electronic components, called ‘network identification by deconvolution’. Here, a generalisation, called ‘thermographic network identification’, is presented to obtain spatially resolved thermal equivalence networks as complete thermal model of the device under study. As a proof of concept, two samples are investigated. The method is discussed on the basis of the obtained results.

13 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PDPatrick Dahlberg
Patrick Dahlberg
NZNils Jonas Ziegeler
Nils Jonas Ziegeler
SSStefan Schweizer
Stefan Schweizer
SSStefan Schweizer
Stefan Schweizer
Active thermography is an established technique for non-destructive testing and defect localisation. For external excitation, powerful light sources are commonly used. In addition to a high optical output, a good signal shape and response characteristic as well as control ports, which allow for multiple operation modes, are important for active thermography applications. In this work, the schematics for an excitation source based on infrared LEDs is presented. It features multiple control modes for easy integration into existing measurement setups as well as sophisticated control electronics to realize a wide range of excitation patterns. The phase and amplitude stability of this prototype is investigated and compared to the performance of a modulated halogen lamp as well as a halogen lamp and mechanical chopper combination.

16 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
NZNils Jonas Ziegeler
Nils Jonas Ziegeler
SSStefan Schweizer
Stefan Schweizer
SSStefan Schweizer
Stefan Schweizer
Network identification by deconvolution is a proven method for determining the thermal structure function of a given device. The method allows to derive the thermal capacitances as well as the resistances of a one-dimensional thermal path from the thermal step response of the device. However, the results of this method are significantly affected by noise in the measured data, which is unavoidable to a certain extent. In this paper, a post-processing procedure for network identification from thermal transient measurements is presented. This so-called optimization-based network identification provides a much more accurate and robust result compared to approaches using Fourier or Bayesian deconvolution in combination with Foster-to-Cauer transformation. The thermal structure function obtained from network identification by deconvolution is improved by repeatedly solving the inverse problem in a multi-dimensional optimization process. The result is a non-diverging thermal structure function, which agrees well with the measured thermal impedance. In addition, the associated time constant spectrum can be calculated very accurately. This work shows the potential of inverse optimization approaches for network identification.

29 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SASimon Helmut Anke
Simon Helmut Anke
NZNils Jonas Ziegeler
Nils Jonas Ziegeler
SSStefan Schweizer
Stefan Schweizer
SSStefan Schweizer
Stefan Schweizer
Thermal transients of small or thermally well-conducting components typically relax with a very short time constant. In some cases, the fastest changes occur on a time scale of a few tens to hundreds of microseconds. Providing a sampling rate higher than 1 kHz is challenging, even for modern infrared cameras. This work presents a periodic non-uniform sampling technique for measuring thermographic transients, which increases the effective sampling rate by one order of magnitude to 10 kHz, resulting in a temporal resolution of 100 μs. The practical application of this technique captures parts of the thermal transient that would otherwise be missed for standard sampling rates. The results confirm the algorithm’s ability to enhance the effective sampling rate, providing a more detailed thermal analysis of rapid transient processes in small-scale electronic components.