The Diagnostic and Statistical Manual of Mental Disorders, 5th Edition (DSM-5) recently included sensory processing abnormalities in the diagnostic criteria for individuals with autism spectrum disorder (ASD). However, there is no standard method for evaluating sensory abnormalities in individuals with ASD. Fifteen individuals with ASD and 15 age- and sex-matched controls were enrolled in this study. We compared objective pain sensitivity by measuring the pain detection threshold and pain tolerance to three different stimuli (electricity, heat, and cold). Then, we compared both subjective pain sensitivity, assessed by the visual analog scale (VAS), and quality of pain, assessed by the short-form McGill Pain Questionnaire (SF-MPQ), to determine the maximum tolerable pain intensities of each stimulation. The pain detection threshold and pain tolerance of individuals with ASD were not impaired, indicating that there were no differences in the somatic perception of pain between groups. However, individuals with ASD were hyposensitive to subjective pain intensity compared to controls (VAS; electrical: p = 0.044, cold: p = 0.011, heat: p = 0.042) and hyposensitive to affective aspects of pain sensitivity (SF-MPQ; electrical: p = 0.0071, cold: p = 0.042). Our results suggest that the cognitive pathways for pain processing are impaired in ASD and, furthermore, that our methodology can be used to assess pain sensitivity in individuals with ASD. Further investigations into sensory abnormalities in individuals with ASD are needed to clarify the pathophysiologic processes that may alter sensory processing in this disorder.
The electroencephalogram (EEG) can reflect brain activity and contains abundant information of different anesthetic states of the brain. It has been widely used for monitoring depth of anesthesia (DoA). In this study, we propose a method that combines multiple EEG-based features with artificial neural network (ANN) to assess the DoA. Multiple EEG-based features can express the states of the brain more comprehensively during anesthesia. First, four parameters including permutation entropy, 95% spectral edge frequency, BetaRatio and SynchFastSlow were extracted from the EEG signal. Then, the four parameters were set as the inputs to an ANN which used bispectral index (BIS) as the reference output. 16 patient datasets during propofol anesthesia were used to evaluate this method. The results indicated that the accuracies of detecting each state were 86.4% (awake), 73.6% (light anesthesia), 84.4% (general anesthesia), and 14% (deep anesthesia). The correlation coefficient between BIS and the index of this method was 0.892 ( ). The results showed that the proposed method could well distinguish between awake and other anesthesia states. This method is promising and feasible for a monitoring system to assess the DoA.
Background: The authors previously reported that, during isoflurane anesthesia, electroencephalographic bicoherence values changed in a fairly restricted region of frequency versus frequency space. The aim of the current study was to clarify the relation between electroencephalographic bicoherence and the isoflurane concentration. Methods: Thirty elective abdominal surgery patients (male and female, aged 34-77 yr, American Society of Anesthesiologists physical status I-II) were enrolled. After electroencephalogram recording with patients in an awake state, anesthesia was induced with 3 mg/kg thiopental and maintained with oxygen and isoflurane. Continuous epidural anesthesia with 80-100 mg/kg 1% lidocaine was also administered. Using software they developed, the authors continuously recorded the FP1-A1 lead of the electroencephalographic signal and expired isoflurane concentration to an IBM-PC compatible computer. After confirming the steady state of each isoflurane (end-tidal concentration at 0.3, 0.5, 0.7, 0.9, 1.1, 1.3, and 1.5%), electroencephalographic bicoherence values were calculated. Results: In a light anesthetic state, electroencephalographic bicoherence values were low (generally < or = 15.0%). At increased concentrations of isoflurane, two peaks of electroencephalographic bicoherence emerged along the diagonal line (f1=f2). The peak emerged at around 4.0 Hz and grew higher as isoflurane concentration increased until it reached a plateau (43.8 +/- 3.5%, mean +/- SD) at isoflurane 0.9%. The other peak, at about 10.0 Hz, also became significantly higher and reached a plateau (32.6 +/- 9.2%) at isoflurane 0.9%; at isoflurane 1.3%, however, this peak slightly decreased. Conclusion: Changes in the height of two electroencephalographic bicoherence peaks correlated well with isoflurane concentration.
Objectives: It has been reported that the effect of intrathecally administered α2 adrenergic receptor (α2 AR) agonists is enhanced in mice that are chronically tolerant to systemic morphine. However, contributory factors have not been identified. Here we examined whether repeated systemic morphine affected the analgesic potency of intrathecal dexmedetomidine and the expression of subtype A, B and C α2 AR (α2A, α2B and α2C AR) in the dorsal root ganglion and dorsal horn in mice.Methods: After subcutaneous injection of morphine or saline for two weeks, dexmedetomidine was administered intrathecally to evaluate its antinociceptive effect. Also, the α2 AR subtypes and µ-opioid receptor mRNA expression in lumbar dorsal root ganglion was quantified using PCR, and α2A and α2C AR in lumbar dorsal root ganglion and dorsal horn were examined by immunohistochemistry.Key findings: Daily morphine enhanced the antinociceptive effect of intrathecal dexmedetomidine, increased all the α2 AR subtypes but decreased the µ-opioid receptor mRNA expression in dorsal root ganglion and increased immunoreactivity of α2A and α2C AR in dorsal root ganglion and dorsal horn.Conclusions: These results suggest that systemic daily morphine enhances the analgesic effect of intrathecal dexmedetomidine via up-regulation of the α2A, α2B and α2C AR in lumbar dorsal root ganglion and dorsal horn.