Pavel A. Shilyagin

Dr. Pavel A. Shilyagin

nanooptics, Institute of Applied Physics, Nizhny Novgorod, Russia
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2009 in Optics and Spectroscopy
Verified
Journal Article
Closed access
PDF file
GGGrigory Gelikonov
Grigory Gelikonov
GGGrigory Gelikonov
Grigory Gelikonov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
An equidistant (in the wavenumber) spectrometer based on a diffraction grating, a compensation prism, and a CCD linear array is developed and implemented for spectral-domain optical coherence...

23 June 2009 in Optics and Spectroscopy
Verified
Journal Article
Closed access
PDF file
GGGrigory Gelikonov
Grigory Gelikonov
GGGrigory Gelikonov
Grigory Gelikonov
IKI. V. Kasatkina
I. V. Kasatkina
DTD. A. Terpelov
D. A. Terpelov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
An efficient technique for the separation of and compensation for coherent noise in spectral optical coherence tomography with parallel spectrum detection is proposed and validated. The coherent...

22 October 2013 in Laser Physics Letters
Verified
Journal Article
Closed access
PDF file
AMAlexander A Moiseev
Alexander A Moiseev
GGGrigory Gelikonov
Grigory Gelikonov
DTDmitry A Terpelov
Dmitry A Terpelov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
GGGrigory Gelikonov
Grigory Gelikonov
A method of OCT imaging with a resolution throughout the investigated volume equal to the resolution in the best-focused region is described. It is based on summation of three-dimensional scattered field distributions at the wavelengths determined by OCT source spectral decomposition. A method of finding parameters needed for algorithmic realization of the summation is also proposed. The proposed approaches are tested on several model media, including biological ones.

26 October 2012 in Laser Physics Letters
Verified
Journal Article
Closed access
AMA A Moiseev
A A Moiseev
GGGrigory Gelikonov
Grigory Gelikonov
DTD A Terpelov
D A Terpelov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
VGV M Gelikonov
V M Gelikonov

15 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Elena KiselevaElena Kiseleva
Elena Kiseleva
Maksim G. RyabkovMaksim G. Ryabkov
Maksim G. Ryabkov
MBMikhail Baleev
Mikhail Baleev
EBEvgeniya Bederina
Evgeniya Bederina
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
Natalia D. GladkovaNatalia D. Gladkova
Natalia D. Gladkova
Introduction: Despite the introduction of increasingly multifaceted diagnostic techniques and the general advances in emergency abdominal and vascular surgery, the outcome of treatment of patients with acute impaired intestinal circulation remains unsatisfactory. The non-invasive and high-resolution technique of optical coherence tomography (OCT) can be used intraoperatively to assess intestine viability and associated conditions that frequently emerge under conditions of impaired blood circulation. This study aims to demonstrate the effectiveness of multimodal (MM) OCT for intraoperative diagnostics of both the microstructure (cross—polarization OCT mode) and microcirculation (OCT angiography mode) of the small intestine wall in patients with acute mesenteric ischemia (AMI). Methods and Participants: A total of 18 patients were enrolled in the study. Nine of them suffered from AMI in segments II-III of the superior mesenteric artery (AMI group), whereby the ischemic segments of the intestine were examined. Nine others were operated on for adenocarcinoma of the colon (control group), thus allowing areas of their normal small intestine to be examined for comparison. Data on the microstructure and microcirculation in the walls of the small intestine were obtained intraoperatively from the side of the serous membrane using the MM OCT system (IAP RAS, Russia) before bowel resection. The MM OCT data were compared with the results of histological examination. Results: The study finds that MM OCT visualized the damage to serosa, muscularis externa, and blood vessels localized in these layers in 100% of AMI cases. It also visualized the submucosa in 33.3% of AMI cases. The MM OCT images of non-ischemic (control group), viable ischemic, and necrotic small intestines (AMI group) differed significantly across stratification of the distinguishable layers, the severity of intermuscular fluid accumulations, and the type and density of the vasculature. Conclusion: The MM OCT diagnostic procedure optimally meets the requirements of emergency surgery. Data on the microstructure and microcirculation of the intestinal wall can be obtained simultaneously in real time without requiring contrast agent injections. The depth of visualization of the intestinal wall from the side of the serous membrane is sufficient to assess the volume of the affected tissues. However, the methodology for obtaining MM OCT data needs to be improved to minimize the motion artefacts generated in actual clinical conditions.

1 May 2012 in Instruments and Experimental Techniques
Verified
Journal Article
Closed access
PDF file
GGGrigory Gelikonov
Grigory Gelikonov
GGGrigory Gelikonov
Grigory Gelikonov
DTD. A. Terpelov
D. A. Terpelov
Pavel A. ShilyaginPavel A. Shilyagin
Pavel A. Shilyagin
A setup for visualizing the internal structure of media, which partially scatter radiation, using the spectral domain optical coherence tomography (OCT) method is described. The special complex of...