Guowen Song

Prof. Guowen Song


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2017 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
HZHui Zhang
Hui Zhang
GSGuowen Song
Guowen Song
HSHui Su
Hui Su
HRHaitao Ren
Haitao Ren
JCJuan Cao
Juan Cao

1 January 2021 in Building and Environment
Verified
Journal Article
Closed access
MZMengying Zhang
Mengying Zhang
RLRui Li
Rui Li
YWYulin Wu
Yulin Wu
LWLiwen Wang
Liwen Wang
GSGuowen Song
Guowen Song
JLJun Li
Jun Li

31 August 2016 in Journal of Industrial Textiles
Verified
Journal Article
Closed access
PDF file
Sumit MandalSumit Mandal
Sumit Mandal
GSGuowen Song
Guowen Song
This study characterizes the thermal protective fabrics of firefighters’ clothing under the exposure of hot surface contact. For this, thermal protective performance of different fabrics was evaluated using a laboratory-simulated hot surface contact test, and various factors affecting the performance were statistically identified. Additionally, heat transfer mechanisms during testing were analytically and mathematically modeled. It has been found that fabric’s constructional features and properties are the key factors to affect its thermal protective performance. In this study, the presence of a thicker thermal liner in a layered fabric system resulted in higher performance; in contrast, a multi-layered fabric system incorporating a moisture barrier in its outer layer displayed the lowest performance. Furthermore, it was demonstrated that a fabric’s air permeability has a minimal impact on performance, whereas weight, thickness, and thermal resistance have a significant positive impact on performance. Based on the analytical and mathematical models developed, it was apparent that conductive heat transfer mainly occurs through fabric during testing, and this conductive heat transfer depends upon the surface roughness and thermal properties (thermal conductivity, density, and specific heat) of the tested fabric. Here, thermal contact resistance between the hot surface and fabric also plays a crucial role in the heat transfer or thermal protective performance of fabric. Moreover, the heat transfer gradually decreases across fabric thickness, which can substantially affect thermal protective performance. This study can advance the theory of textile/materials science through better understanding of heat transfer in fabrics. This understanding can help in developing an integrated knowledge of fabric properties, heat transfer through fabrics, and thermal protective performance of fabrics. The findings from this study can also assist textile/material engineers with the development of a high performance thermal protective fabric for clothing to provide better occupational safety and health for firefighters.

5 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
Sumit MandalSumit Mandal
Sumit Mandal
NMNur-Us-Shafa Mazumder
Nur-Us-Shafa Mazumder
RARobert Agnew
Robert Agnew
GSGuowen Song
Guowen Song
Rui LiRui Li
Rui Li
In 2017, more than 60,000 firefighters and oilfield-workers injuries and fatalities occurred while they were working under various thermal hazards such as flame, radiant heat, steam, etc., or due to their significant heat stress related discomfort. The majority of these burn injuries and fatalities results from an inadequate protection and comfort provided by firefighters’ and oilfield-workers’ fire protective polymeric textile materials used in their workwear. Hence, both the thermal protective and thermo-physiological comfort performance of fabrics used in workwear significantly contribute to limit firefighters’ and oilfield-workers’ skin burns and heat stress. Considering this, previous studies have focused on characterizing and developing empirical models to predict the protective and comfort performance based on physical properties of the fabrics. However, there are still some technical knowledge gaps in the existing literature related to this. This paper critically reviewed the literature on characterization and modeling of thermal protective and thermo-physiological comfort performance of fire protective textile fabric materials. The key issues in this field have been indicated in order to provide direction for the future research and advance this scientific field for better protection and comfort of the firefighters and oilfield-workers.

9 May 2024 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
YSYufa Sun
Yufa Sun
SESasha Eckstein
Sasha Eckstein
XNXinyi Niu
Xinyi Niu
MYMichael Yermakov
Michael Yermakov
SGSergey Grinshpun
Sergey Grinshpun
GSGang Sun
Gang Sun

1 February 2017 in Textile Research Journal
Verified
Journal Article
Open access
HZHui Zhang
Hui Zhang
GSGuowen Song
Guowen Song
HRHaitao Ren
Haitao Ren
JCJuan Cao
Juan Cao
Current firefighter protective clothing is composed of multilayer fabric systems. The outer shell fabrics inevitably become wet in the process of firefighters performing their duties, and sweat may also increase moisture in the inner layers of protective clothing. In this study, two kinds of outer shell fabrics (aramid IIIA fabric and aramid 1313 and flame-retardant viscose-blended fabric) and two kinds of thermal liner fabrics with different thicknesses were selected. Three wetness conditions were simulated for the outer shell fabric, thermal liner fabric and both fabrics together. A modified thermal protective performance (TPP) tester was applied to assess TPP provided by these wetted fabrics; in addition, second-degree skin burn time was predicted and absorbed energy indexes were calculated. The regression method was employed to create fitting curves for absorbed energy and second-degree burn time in different configurations and the Pearson correlation was established to analyze their relationship, in which the lowest R2 value could reach 0.9122 and p-values were all much less than 0.05. Performance results for both wet conditions indicated that outer shell moisture and a thicker thermal liner have a positive and increased negative effect, respectively, on fabric TPP. When the sample S-3-D (aramid 1313 and flame-retardant viscose-blended fabric, moisture barrier and the thin thermal liner) was both wetted in the outer shell and thermal liner, its second-degree burn time was improved by 12.8% over performance in dry conditions. These findings may have important applications for the design and manufacture of optimal protective performance clothing systems.