Fernando De Ory

Dr. Fernando De Ory

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2012 in Journal of Medical Virology
Verified
Journal Article
Closed access
PDF file
FOFernando De Ory
Fernando De Ory
AAAna Avellon
Ana Avellon
JEJuan E. Echevarría
Juan E. Echevarría
MSMaria Paz DE SALUD Sanchez-Seco
Maria Paz DE SALUD Sanchez-Seco
GTG. Trallero
G. Trallero
MMMaría Sonia Vázquez Morón
María Sonia Vázquez Morón

1 January 2004 in European Journal of Epidemiology
Verified
Journal Article
Closed access
PDF file
FOFernando De Ory
Fernando De Ory
RRR. Ramírez
R. Ramírez
LCL. García Comas
L. García Comas
PLP. León
P. León
MSM.J. Sagües
M.J. Sagües
JSJ.C. Sanz
J.C. Sanz

1 March 2011 in Clinical and Vaccine Immunology
Verified
Journal Article
Closed access
PDF file
FOFernando De Ory
Fernando De Ory
MGMaría Eulalia Guisasola
María Eulalia Guisasola
JSJuan Carlos Sanz
Juan Carlos Sanz
IGIsabel García-Bermejo
Isabel García-Bermejo
To compare the performance of four diagnostic commercial systems for Epstein-Barr virus (EBV) serology (for IgM and IgG virus capsid antigen [VCA] and EBV nuclear antigen [EBNA] antibodies), a collection of 125 samples from clinically suspected infectious mononucleosis cases was studied. Indirect immunofluorescence (IIF) for VCA IgM and IgG antibodies and anticomplement immunofluorescence for EBNA antibodies (Meridian Bioscience Inc.) were used as reference methods. By these methods, the cases were classified EBV primary infection (presence of IgM to VCA or IgG to VCA in the absence of EBNA antibodies;n= 82), EBV past infection (presence of VCA IgG and EBNA antibodies in the absence of VCA IgM;n= 26), or no infection (negative for the three markers;n= 17). The following systems were tested: two chemiluminescent immunoassays (CLIAs; the Liason [CLIA-L; DiaSorin] and the Immulite 2000 [CLIA-I; Siemens]), immunofiltration (IF; All.Diag), and an enzyme-linked immunosorbent assay (ELISA; DiaSorin). In the IgM assays, sensitivities ranged from 67.1% (ELISA) to 92.2% (CLIA-L) and specificities ranged from 93.8% (CLIA-L) to 100% (IF). In the VCA IgG assays, sensitivities varied from 79.4% (IF) to 94.4% (CLIA-I) and specificities varied from 94.4% (IF and CLIA-L) to 100% (CLIA-I and ELISA). In EBNA assays, sensitivities ranged from 78.1% (IF) to 93.8% (CLIA-I) and specificities ranged from 32.3% (CLIA-L) to 91.4% (IF). In relation to EBV profiles, the corresponding figures for sensitivity (in detecting primary infection) for IF, CLIA-L, CLIA-I, and ELISA were 92.7%, 93.8%, 89%, and 89.6%, respectively, and those for specificity (to exclude primary recent infection) were 90.7%, 94.6%, 97.7%, and 95.2%, respectively. Although there were limitations in some individual markers, especially CLIA-L for EBNA IgG, the systems evaluated appear to be useful for diagnosis of EBV infection.

3 July 2015 in APMIS
Verified
Journal Article
Closed access
PDF file
FOFernando De Ory
Fernando De Ory
TMTeodora Minguito
Teodora Minguito
PBPilar Balfagón
Pilar Balfagón
JSJuan C. Sanz
Juan C. Sanz

1 June 2006 in Journal of Clinical Virology
Verified
Journal Article
Closed access
FOFernando De Ory
Fernando De Ory
JEJosé Manuel Echevarría
José Manuel Echevarría
GKGeorge Kafatos
George Kafatos
Cleo AnastassopoulouCleo Anastassopoulou
Cleo Anastassopoulou
NANick Andrews
Nick Andrews
RVRobert Vranckx
Robert Vranckx

31 October 2006 in APMIS
Verified
Journal Article
Closed access
PDF file
JSJuan Carlos Sanz
Juan Carlos Sanz
MMMaría DEL Mar Mosquera
María DEL Mar Mosquera
JEJuan E. Echevarría
Juan E. Echevarría
MFMarisa Fernández
Marisa Fernández
NHNieves Herranz
Nieves Herranz
FOFernando De Ory
Fernando De Ory