Medulloblastoma (MB) is the most common malignant pediatric brain tumor. Despite the progress of new treatments, the risk of recurrence, morbidity, and death remains significant and the long-term adverse effects in survivors are substantial. The fraction of cancer stem-like cells (CSCs) because of their self-renewal ability and multi-lineage differentiation potential is critical for tumor initiation, growth, and resistance to therapies. For the development of new CSC-targeted therapies, further in-depth studies are needed using enriched and stable MB-CSCs populations. This work, aimed at identifying the amount of CSCs in three available human cell lines (DAOY, D341, and D283), describes different approaches based on the expression of stemness markers. First, we explored potential differences in gene and protein expression patterns of specific stem cell markers. Then, in order to identify and discriminate undifferentiated from differentiated cells, MB cells were characterized using a physical characterization method based on a high-frequency dielectrophoresis approach. Finally, we compared their tumorigenic potential in vivo, through engrafting in nude mice. Concordantly, our findings identified the D283 human cell line as an ideal model of CSCs, providing important evidence on the use of a commercial human MB cell line for the development of new strategic CSC-targeting therapies.
Glioblastoma (GBM) is one of the most aggressive solid tumors, particularly due to the presence of cancer stem cells (CSCs). Nowadays, the characterization of this cell type with an efficient, fast and low-cost method remains an issue. Hence, we have developed a microfluidic lab-on-a-chip based on dielectrophoresis (DEP) single cell electro-manipulation to measure the two crossover frequencies: fx01 in the low-frequency range (below 500 kHz) and fx02 in the ultra-high-frequency range (UHF, above 50 MHz). First, in vitro conditions were investigated. An U87-MG cell line was cultured in different conditions in order to induce an undifferentiated phenotype. Then, ex vivo GBM cells from patients’ primary cell culture were passed through the developed microfluidic system and characterized in order to reflect clinical conditions. This article demonstrates that the usual exploitation of low-frequency range DEP does not allow the discrimination of the undifferentiated GBM cells from the differentiated one. However, the presented study highlights the use of UHF-DEP as a relevant discriminant parameter. The proposed microfluidic lab-on-a-chip is able to follow the kinetics of U87-MG phenotype transformation in a CSC enrichment medium and the cancer stem cells phenotype acquirement.
1 December 2009 in International Journal of Microwave and Wireless Technologies
This paper presents an original biosensor chip allowing determination of intrinsic relative permittivity of biological cells at microwave frequencies. This sensor permits non-invasive cell identification and discrimination using an RF signal to probe intracellular medium of biological samples. Indeed, these sensors use an RF planar resonator that allows detection capabilities on less than 10 cells, thanks to the microscopic size of its sensitive area. Especially, measurements between 15 and 35 GHz show the ability label-free biosensors to differentiate two human cell types using their own electromagnetic characteristics. The real part of permittivity of cells changes from 20 to 48 for the nervous system cell types studied. The proposed biodetection method is detailed and we show how the accuracy and the repeatability of measurements have been improved to reach reproducible measurements.
Glioblastoma (GBM) is one of the most aggressive solid tumors, particularly due to the presence of cancer stem cells (CSCs). Today the characterization of this type of cells with an efficient, fast and low-cost method remains an issue. Hence, we have developed a microfluidic lab-on-a-chip based on dielectrophoresis (DEP) single cell electro-manipulation to measure the two crossover frequencies: fx01in low frequency range (below 500 kHz) and fx02in Ultra High Frequency range (UHF, above 50 MHz). First, in vitro conditions were investigated. U87-MG cell lines were cultured in different conditions in order to induce an undifferentiated phenotype. Then, ex vivo GBM cells from patients’ primary cell culture, were passed through the developed microfluidic system and characterized in order to reflect clinical conditions. This article demonstrates that the usual exploitation of low frequency range DEP does not allow the discrimination of the undifferentiated from the differentiated phenotypes of GBM cells. However, the presented study highlights the use of UHF-DEP as a relevant discriminant parameter. The proposed microfluidic lab-on-a-chip is able to follow the kinetic of U87-MG phenotype transformation in a CSC enrichment medium and their cancer stem cells phenotype acquirement.
C ancer stem cells remain a challenge to isolate and characterize because of their plastic phenotype. Using a microfluidic lab-on-a-chip based on ultra-high frequency dielectophoresis, we measured the electromagnetic signature of colorectal cancer cells and demonstrated that cancer stem cells show a distinct and lower electromagnetic signature than differentiated cells. The release of extracellular vesicles from tumor cells can drive tumor progression and metastasis development. As extracellular vesicles from cancer stem cells carry more aggressive content, we treated colorectal cancer cells with these vesicles to test whether the lab-on-a-chip can detect a change in phenotype. The electromagnetic signature of treated cells is modified in comparison to untreated cells and sometimes even when no biological change is observed. The lab-on-a-chip provides rapid and relevant result without prior labeling compared to conventional biological approaches. It could be useful in the clinic for early detection of cancer stem cells in the tumor mass and for monitoring the aggressive potential of extracellular vesicles in the bloodstream in order to adapt therapeutic management and prevent relapse.
Tumor Mutational Burden (TMB) has emerged as a crucial biomarker to guide patient eligibility for immunotherapy. However, whole exome sequencing, the gold-standard method for TMB measurement, remains limited in accessibility due to its high costs, operational complexity, and lengthy processing times. To address these limitations, we investigated whether Ultra-High-Frequency (UHF) technology could serve as a novel approach to assess TMB by analyzing the crossover frequencies or electromagnetic signature (EMS) of cancer cells on a lab-on-a-chip biosensor, integrating microfluidics and dielectrophoresis. In a panel of 12 cancer cell lines with varying TMB levels, we observed that EMS showed an upward shift correlating with higher TMB, particularly in solid tumor cell lines. This finding suggests a potential relationship between TMB and EMS. To further explore this hypothesis, we artificially increased mutation levels by treating cells with the highly mutagenic compound N-ethyl-N-nitrosourea (ENU). Results showed that EMS captured significant TMB variations in ENU-treated cells with enhanced proliferative capacity compared to their parental counterparts. These results underscore the importance of matched control samples for reliable EMS measurements. Altogether, our findings highlight the potential of EMS to detect TMB variations associated with proliferative activity, a key hallmark of cancer cells, thereby enabling a more precise stratification of cancer cells. Highlights: We propose a new biosensor to improve patient stratification for ICI eligibility High frequency fields and dielectric spectroscopy can estimate TMB in cancer cells Significant changes in UHF-DEP signatures correlate with varying TMB levels UHF-DEP provides a cheap, rapid and label-free method to predict ICI response Offers an innovative and complementary marker to conventional diagnostic approaches Graphical