Xingjun Zhu

Dr. Xingjun Zhu

School of Physical Science and Technology, ShanghaiTech University, Shanghai, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2019 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
Xingjun ZhuXingjun Zhu
Xingjun Zhu
CVChau Vo
Chau Vo
MTMadelynn Taylor
Madelynn Taylor
BSBryan Ronain Smith
Bryan Ronain Smith
Recent studies have revealed the effects of shape on in vivo nanoparticle circulation, distribution, extravasation, and cellular uptake. Morphology is therefore becoming a key factor to be considered in the rational design of nanoparticulate systems for specific biomedical applications such as targeted drug delivery. Technologies for reliable and scalable fabrication of shape-specific micro- and nanoparticles are emerging, which will allow further investigations into this crucial parameter that is poised to substantially impact nanomedicine.

9 September 2019 in Nano Letters
Verified
Journal Article
Closed access
Xingjun ZhuXingjun Zhu
Xingjun Zhu
JLJianfeng Li
Jianfeng Li
PPPeng Peng
Peng Peng
NNNiloufar Hosseini Nassab
Niloufar Hosseini Nassab
BSBryan Ronain Smith
Bryan Ronain Smith

15 March 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
YWYukai Wu
Yukai Wu
FLFang Li
Fang Li
YWYanan Wu
Yanan Wu
HWHao Wang
Hao Wang
LGLiangtao Gu
Liangtao Gu
Xingjun ZhuXingjun Zhu
Xingjun Zhu
Nanothermometers enable the detection of temperature changes at the microscopic scale, which is crucial for elucidating biological mechanisms and guiding treatment strategies. However, temperature monitoring of micron-scale structures in vivo using luminescent nanothermometers remains challenging, primarily due to the severe scattering effect of biological tissue that compromises the imaging resolution. Herein, a lanthanide luminescence nanothermometer with a working wavelength beyond 1500 nm is developed to achieve high-resolution temperature imaging in vivo. The energy transfer between lanthanide ions (Er3+ and Yb3+) and H2O molecules, called the environment quenching assisted downshifting process, is utilized to establish temperature-sensitive emissions at 1550 and 980 nm. Using an optimized thin active shell doped with Yb3+ ions, the nanothermometer’s thermal sensitivity and the 1550 nm emission intensity are enhanced by modulating the environment quenching assisted downshifting process. Consequently, minimally invasive temperature imaging of the cerebrovascular system in mice with an imaging resolution of nearly 200 μm is achieved using the nanothermometer. This work points to a method for high-resolution temperature imaging of micron-level structures in vivo, potentially giving insights into research in temperature sensing, disease diagnosis, and treatment development.

1 November 2022 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
XMXiao Meng
Xiao Meng
QHQian Hu
Qian Hu
XWXi Wang
Xi Wang
TMTengfei Ma
Tengfei Ma
WLWeimin Liu
Weimin Liu
CYChunhong Ye
Chunhong Ye
A water-resistance polymer-based room temperature phosphorescence material (RTP) with an ultralong lifetime and afterglow was achieved by doping PAHs within a rigid polymeric network duringin situpolymerization.

2 August 2022 in Nanoscale Horizons
Verified
Journal Article
Closed access
PDF file
QHQian Hu
Qian Hu
NKNa Kong
Na Kong
YCYingjie Chai
Yingjie Chai
ZXZhenyu Xing
Zhenyu Xing
YWYukai Wu
Yukai Wu
Xingjun ZhuXingjun Zhu
Xingjun Zhu
Lanthanide luminescence nanothermometers (LNTs) provide microscopic, highly sensitive, and visualizable optical signals for reporting temperature information, which is particularly useful in biomedicine to achieve precise diagnosis and therapy. However, LNTs with efficient emissions at the long-wavelength region of the second and the third near-infrared (NIR-II/III) biological window, which is more favourable for in vivo thermometry, are still limited. Herein, we present a lanthanide-doped nanocomposite with Tm3+ and Nd3+ ions as emitters working beyond 1200 nm to construct a dual ratiometric LNT. The cross-relaxation processes among lanthanide ions are employed to establish a strategy to enhance the NIR emissions of Tm3+ for bioimaging-based temperature detection in vivo. The dual ratiometric probes included in the nanocomposite have potential in monitoring the temperature difference and heat transfer at the nanoscale, which would be useful in modulating the heating operation more precisely during thermal therapy and other biomedical applications. This work not only provides a powerful tool for temperature sensing in vivo but also proposes a method to build high-efficiency NIR-II/III lanthanide luminescent nanomaterials for broader bio-applications.

1 September 2024 in Aggregate
Verified
Journal Article
Open access
RLRuotong Li
Ruotong Li
KLKaiyuan Liu
Kaiyuan Liu
QHQian Hu
Qian Hu
JSJiakang Shen
Jiakang Shen
DZDongqing Zuo
Dongqing Zuo
WSWei Sun
Wei Sun
Osteosarcoma (OS) is characterized by an unfavorable prognosis and high mortality rates, with the local recurrence attributed to residual lesions post‐surgery being a major reason for treatment failure. Precise and tumor‐specific resection guidance to minimize recurrence remains a significant challenge. In the present study, a nanosystem based on aggregation‐induced emission (AIE) molecules with emission in the second near‐infrared window is proposed for the synergistic fluorescence (FL) and chemiluminescence (CL) imaging‐guided surgical resection for the elimination of tumor foci. The designed AIE molecule, BBTD14, exhibits stable FL with a high quantum yield of up to 3.95%, which effectively matches the energy levels of CL high‐energy states, generating the longest emission wavelength of CL reported to date. Targeted tumor imaging‐guided surgery (IGS) is facilitated by FL and CL nanoprobes (FLNP and CLNP) constructed based on BBTD14. During OS surgery, the FLNP, with the stability of FL and a high targeting capability, was first intravenously used to guide the surgical removal of the main tumor. Subsequently, CLNP was locally incubated to facilitate rapid and accurate evaluation of residual tumors at the operative border. High signal‐to‐noise ratio CL imaging was achieved after spraying with hydrogen peroxide, thereby overcoming the limitations of intraoperative frozen sections. The proposed technique also significantly reduced the recurrence rates in OS mouse models and exhibited high marker specificity in ex vivo OS patient pathology samples, confirming its potential in clinical applications and providing a unique perspective for developing IGS.