Xavier Gasparutto

Dr. Xavier Gasparutto

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in EFORT Open Reviews
Verified
Journal Article
Open access
PDF file
PDPeter Luca DiGiovanni
Peter Luca DiGiovanni
XGXavier Gasparutto
Xavier Gasparutto
SAStéphane Armand
Stéphane Armand
DHDidier Hannouche
Didier Hannouche
Offsets in the frontal plane are important for hip function. Research on total hip arthroplasty (THA) surgery agrees that increasing femoral offset up to 5 mm could improve functional outcome measures. The literature indicates that global offset is a key parameter that physicians should restore within 5 mm during surgery and avoid decreasing. Substantiated findings on acetabular offset are lacking despite its recognized importance, and the medialization approach must be assessed in light of its shortcomings. Future research, possibly through improved measurement, unified definitions, patient-specific surgical planning, and technology-enhanced surgical control, with specific focus on acetabular offset, is needed to better understand its impact on THA outcomes.

10 September 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XGXavier Gasparutto
Xavier Gasparutto
MGMathieu Gueugnon
Mathieu Gueugnon
DLDavy Laroche
Davy Laroche
PMPierre Martz
Pierre Martz
DHDidier Hannouche
Didier Hannouche
SAStéphane Armand
Stéphane Armand
Six to eight months after total hip arthroplasty, patients only attain 80% of the functional level of control groups. Understanding which functional tasks are most affected could help reduce this deficit by guiding rehabilitation towards them. The timed up-and-go test bundles multiple tasks together in one test and is a good indicator of a patient’s overall level of function. Previously, biomechanical analysis of its phases was used to identify specific functional deficits in pathological populations. To the best of our knowledge, this analysis has never been performed in patients who have undergone total hip arthroplasty. Seventy-one total hip arthroplasty patients performed an instrumented timed up-and-go test in a gait laboratory before and six months after surgery; fifty-two controls performed it only once. Biomechanical features were selected to analyse the test’s four phases (sit-to-stand, walking, turning, turn-to-sit) and mean differences between groups were evaluated for each phase. On average, six months after surgery, patients’ overall test time rose to 80% of the mean of the control group. The walking phase was revealed as the main deficiency before and after surgery (-41 ± 47% and -22 ± 32% slower, respectively). High standard deviations indicated that variability between patients was high. On average, patients showed improved results in every phase of the timed up-and-go test six months after surgery, but residual deficits in function differed between those phases. This simple test could be appropriate for quantifying patient-specific deficits in function and hence guiding and monitoring post-operative rehabilitation in clinical settings.

11 January 2022 in The Knee
Verified
Journal Article
Closed access
ABAlice Bonnefoy-Mazure
Alice Bonnefoy-Mazure
MAMichael Attias
Michael Attias
XGXavier Gasparutto
Xavier Gasparutto
KTKatia Turcot
Katia Turcot
SAStéphane Armand
Stéphane Armand
HMHermes H. Miozzari
Hermes H. Miozzari

29 January 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XGXavier Gasparutto
Xavier Gasparutto
JWJennifer Wegrzyk
Jennifer Wegrzyk
KRKevin Rose-Dulcina
Kevin Rose-Dulcina
DHDidier Hannouche
Didier Hannouche
SAStéphane ARMAND
Stéphane ARMAND
In clinical gait analysis, measurement errors impede the reliability and repeatability of the measurements. This extrinsic variability can potentially mislead the clinical interpretation of the analysis and should thus be minimised. Skin marker misplacement has been identified as the largest source of extrinsic variability between measurements. The goal of this study was to test whether the fusion of motion capture and 3D medical imaging could reduce extrinsic variability due to skin marker misplacement. The fusion method consists in using anatomical landmarks identified with 3D medical imaging to correct marker misplacements. To assess the reduction of variability accountable to the fusion method, skin marker misplacements were voluntarily introduced in the measurement of the pelvis and hip kinematics during gait for two patients scheduled for unilateral hip arthroplasty and two patients that underwent unilateral hip arthroplasty. The root mean square deviation was reduced by -78 ± 15% and the range of variability by -80 ± 16% for the pelvis and hip kinematics in average. These results showed that the fusion method could significantly reduce the extrinsic variability due to skin marker misplacement and thus increase the reliability and repeatability of motion capture measurements. However, the identification of anatomical landmarks via medical imaging is a new source of extrinsic variability that should be assessed before considering the fusion method for clinical applications.

11 December 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
XGXavier Gasparutto
Xavier Gasparutto
PBPauline Besonhe
Pauline Besonhe
PDPeter Luca DiGiovanni
Peter Luca DiGiovanni
MZMatthieu Zingg
Matthieu Zingg
SBSana Boudabbous
Sana Boudabbous
DHDidier Hannouche
Didier Hannouche
Bi-plane X-ray provides 3D measurements of the lower limb based on the identification of anatomical landmarks in sagittal and frontal X-rays. In clinical practice, such measurements involve multiple operators and sessions. This study aimed at evaluating the reliability of anatomical landmarks identification and geometric parameters of the pelvis and femur measured with bi-plane X-rays before and after total hip arthroplasty (THA). Twenty-eight patients undergoing primary THA were selected retrospectively. Two operators performed three reconstructions for each patient before and after THA. Intraclass correlation (ICC) and smallest detectable change (SDC) were computed for intra-operator, inter-operator, and test–retest conditions. Most anatomical landmark positions had good to excellent SDC (< 5 mm) apart from the centre of the sacral slope, greater trochanter, and anterior superior iliac spines (up to 7.1, 16.9, and 21.5 mm respectively). Geometric parameters had moderate to excellent SDC, apart from femoral and stem torsion, pelvic incidence, and APP inclination with poor SDC (9–12°). The sagittal view had significantly higher measurement errors than the frontal view. Test–retest and inter-operator conditions had no significant differences suggesting a low influence of patient posture. Osteoarthritis and the presence of implants did not seem to influence reliability and measurement error. This study could be used as a reference when assessing lower limb structure with bi-plane X-rays.

5 December 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
XGXavier Gasparutto
Xavier Gasparutto
ABAlice Bonnefoy-Mazure
Alice Bonnefoy-Mazure
MAMichael Attias
Michael Attias
KTKatia Turcot
Katia Turcot
SAStéphane Armand
Stéphane Armand
HMHermès H Miozzari
Hermès H Miozzari
Total Knee Arthroplasty has well-established success in relieving knee pain and improving function but patients do not reach functional levels of control groups after surgery and 20% of patients remain unsatisfied. To understand the different patient profiles and develop patient-specific approaches of care, functional phenotypes based on knee biomechanics during gait have been evaluated. To widen the understanding of patient’s function, it seems crucial to consider the gait devieations at the whole body level. Thus, this study aims at 1) assessing the impact of knee OA on full-body gait mechanics, 2) assessing whether potential deviations persist one year after TKA surgery, and 3) their potential impact on satisfaction. To that end, clinical gait analysis was performed before and one year after surgery for 100 patients planned for unilateral primary TKA, along with 32 healthy participants as control group. Patients were clustered by applying K-means algorithms on full-body kinematic features of gait before surgery. The knee was excluded from classification to focus on full-body kinematics. Differences between groups, with controls, as well as before and after surgery were evaluated for patients reported outcome measures, kinematic features, and spatio-temporal parameters. Three functional groups were identified. One low-functioning cluster with mostly elderly women showing significant functional improvement one year after surgery, and two high-functioning clusters differentiated by pelvis tilt (anteversion vs. retroversion), sagittal knee alignment (varus vs. neutral), and knee flexion during stance phase (flexum vs. extended) that showed limited improvement one year after surgery. Satisfaction rates were similar among clusters and mental scores improved for all clusters. High functioning patients may benefit from TKA, mostly due to pain reduction, but may not see significant improvement of their function, with no clear impact on satisfaction rate. On the contrary, patients with important functional limitation are more likely to improve both pain and functional outcomes.