Jonghyun Eom

Dr. Jonghyun Eom

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YTYoon-Oh Tak
Yoon-Oh Tak
APAnjin Park
Anjin Park
JCJanghoon Choi
Janghoon Choi
JEJonghyun Eom
Jonghyun Eom
HKHYUK SANG KWON
HYUK SANG KWON
Joo Beom EomJoo Beom Eom
Joo Beom Eom
Whole slide imaging (WSI) refers to the process of creating a high-resolution digital image of a whole slide. Since digital images are typically produced by stitching image sequences acquired from different fields of view, the visual quality of the images can be degraded owing to shading distortion, which produces black plaid patterns on the images. A shading correction method for brightfield WSI is presented, which is simple but robust not only against typical image artifacts caused by specks of dust and bubbles, but also against fixed-pattern noise, or spatial variations in pixel values under uniform illumination. The proposed method comprises primarily of two steps. The first step constructs candidates of a shading distortion model from a stack of input image sequences. The second step selects the optimal model from the candidates. The proposed method was compared experimentally with two previous state-of-the-art methods, regularized energy minimization (CIDRE) and background and shading correction (BaSiC) and showed better correction scores, as smooth operations and constraints were not imposed when estimating the shading distortion. The correction scores, averaged over 40 image collections, were as follows: proposed method, 0.39 ± 0.099; CIDRE method, 0.67 ± 0.047; BaSiC method, 0.55 ± 0.038. Based on the quantitative evaluations, we can confirm that the proposed method can correct not only shading distortion, but also fixed-pattern noise, compared with the two previous state-of-the-art methods.

26 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJanghoon Choi
Janghoon Choi
JSJun Geun Shin
Jun Geun Shin
HKHYUK SANG KWON
HYUK SANG KWON
YTYoon-Oh Tak
Yoon-Oh Tak
HPHyeong Ju Park
Hyeong Ju Park
JEJonghyun Eom
Jonghyun Eom
We developed a single-camera-based near-infrared (NIR) fluorescence imaging device using indocyanine green (ICG) NIR fluorescence contrast agents for image-induced surgery. In general, a fluorescent imaging system that simultaneously provides color and NIR images uses two cameras, which is disadvantageous because it increases the imaging head of the system. Recently, a single-camera-based NIR optical imaging device with quantum efficiency partially extended to the NIR region was developed to overcome this drawback. The system used RGB_NIR filters for camera sensors to provide color and NIR images simultaneously; however, the sensitivity and resolution of the infrared images are reduced by 1/4, and the exposure time and gain cannot be set individually when acquiring color and NIR images. Thus, to overcome these shortcomings, this study developed a compact fluorescent imaging system that uses a single camera with two complementary metal–oxide semiconductor (CMOS) image sensors. Sensitivity and signal-to-background ratio were measured according to the concentrations of ICG solution, exposure time, and camera gain to evaluate the performance of the imaging system. Consequently, the clinical applicability of the system was confirmed through the toxicity analysis of the light source and in vivo testing.

13 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJanghoon Choi
Janghoon Choi
JSJun Geun Shin
Jun Geun Shin
YTYoon-Oh Tak
Yoon-Oh Tak
YSYoungseok Seo
Youngseok Seo
JEJonghyun Eom
Jonghyun Eom
In this study, we propose a single camera-based dual-channel near-infrared (NIR) fluorescence imaging system that produces color and dual-channel NIR fluorescence images in real time. To simultaneously acquire color and dual-channel NIR fluorescence images of two fluorescent agents, three cameras and additional optical parts are generally used. As a result, the volume of the image acquisition unit increases, interfering with movements during surgical procedures and increasing production costs. In the system herein proposed, instead of using three cameras, we set a single camera equipped with two image sensors that can simultaneously acquire color and single-channel NIR fluorescence images, thus reducing the volume of the image acquisition unit. The single-channel NIR fluorescence images were time-divided into two channels by synchronizing the camera and two excitation lasers, and the noise caused by the crosstalk effect between the two fluorescent agents was removed through image processing. To evaluate the performance of the system, experiments were conducted for the two fluorescent agents to measure the sensitivity, crosstalk effect, and signal-to-background ratio. The compactness of the resulting image acquisition unit alleviates the inconvenient movement obstruction of previous devices during clinical and animal surgery and reduces the complexity and costs of the manufacturing process, which may facilitate the dissemination of this type of system.


2 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
JSJun Geun Shin
Jun Geun Shin
JEJonghyun Eom
Jonghyun Eom
A noncontact photoacoustic and fluorescence dual-modality imaging system is proposed, which integrates a fiber-based fluorescence imaging system with noncontact photoacoustic imaging using a specially fabricated double-cladding fiber (DCF) coupler and a DCF lens. The performance of the DCF coupler and lens was evaluated, and the feasibility of this new imaging system was demonstrated using simple tubing phantoms with black ink and fluorophore. Our imaging results demonstrated that the multimodal imaging technique can simultaneously acquire photoacoustic and fluorescence images without coming into contact with the sample. Consequently, the developed method is the first noncontact scheme among multimodal imaging systems that is integrated with a photoacoustic imaging system, which can provide varied and complementary information about the sample.