Lyme borreliosis (LB), caused by spirochetes belonging to the Borrelia burgdorferi sensu lato complex, is the most common tick-borne infection in Europe. Laboratory diagnosis of LB is mainly based on the patients’ medical history, clinical signs and symptoms in combination with detection of Borrelia-specific antibodies where indirect enzyme-linked-immunosorbent assay (ELISA) is the most widely used technique. The objective of the study was to evaluate and compare the diagnostic accuracy (sensitivities and specificities) of serological tests that are currently in use for diagnosis of LB in clinical laboratories in Northern Europe, by use of a large serum panel. The panel consisted of 195 serum samples from well-characterized and classified patients under investigation for clinically suspected LB (n = 59) including patients with Lyme neuroborreliosis, Lyme arthritis, acrodermatitis chronica atrophicans, erythema migrans or other diseases (n = 112). A total of 201 serum samples from healthy blood donors were also included. The panel (396 serum samples altogether) was sent to 12 clinical laboratories (using five different ELISA methods) as blinded for group affiliation and the laboratories were asked to perform serological analysis according to their routine procedure. The results from the study demonstrated high diagnostic concordance between the laboratories using the same diagnostic assay and lower diagnostic concordance between laboratories using different diagnostic assays. For IgG, the results were in general rather homogenous and showed an average sensitivity of 88% (range 85–91%) compared to IgM which showed lower average sensitivity of 59% (range 50–67%) and more heterogeneous results between assays and laboratories.
6 August 2018 in European Journal of Clinical Microbiology & Infectious Diseases
Anti-Borrelia antibodies in the cerebrospinal fluid (CSF) are required for definite diagnosis of Lyme neuroborreliosis (LNB). However, children often present with early LNB, and antibody production in the CSF may not be demonstrated. Recent studies have suggested the chemokine CXCL13 to be an early marker for LNB. The aim of the study was to evaluate CXCL13 for laboratory diagnosis in pediatric LNB patients and to evaluate the association with pleocytosis in CSF, clinical features, and recovery. CSF samples were collected from LNB patients, classified as definite LNB (n = 44) or possible LNB (n = 22), and controls classified as non-LNB (n = 102) or other specific diagnoses (n = 23). CSF samples were analyzed with the recomBead CXCL13 assay (Mikrogen Diagnostik, Germany), cut-off 160 pg/mL. CXCL13 was significantly higher in LNB patients compared to controls (p < 0.001). Among LNB patients, 58/66 had elevated CXCL13, and among controls, 111/125 had CXCL13 levels under cut-off (sensitivity 88%, specificity 89%). In LNB patients with pleocytosis but no detectable anti-Borrelia antibodies in CSF (possible LNB), CXCL13 was elevated in 16/22 (73%). A weak correlation between CXCL13 and pleocytosis in CSF was found in LNB patients (Rho = 0.46, p < 0.01), but no differences in CXCL13 levels in relation to specific clinical features. In conclusion, CXCL13 is elevated in CSF in children with LNB, showing acceptable sensitivity and specificity. In patients with possible LNB, CXCL13 was elevated in a majority of cases (73%) and is suggested as a complementary diagnostic tool in pediatric LNB patients. CXCL13 was not associated with specific clinical features or recovery.
Lyme borreliosis (LB) is the most common tick transmitted disease in Europe. The diagnosis of LB today is based on the patient´s medical history, clinical presentation and laboratory findings. The laboratory diagnostics are mainly based on antibody detection, but in certain conditions molecular detection by polymerase chain reaction (PCR) may serve as a complement. The purpose of this study was to evaluate the analytical sensitivity, analytical specificity and concordance of eight different real-time PCR methods at five laboratories in Sweden, Norway and Denmark. Each participating laboratory was asked to analyse three different sets of samples (reference panels; all blinded) i) cDNA extracted and transcribed from water spiked with cultured Borrelia strains, ii) cerebrospinal fluid spiked with cultured Borrelia strains, and iii) DNA dilution series extracted from cultured Borrelia and relapsing fever strains. The results and the method descriptions of each laboratory were systematically evaluated. The analytical sensitivities and the concordance between the eight protocols were in general high. The concordance was especially high between the protocols using 16S rRNA as the target gene, however, this concordance was mainly related to cDNA as the type of template. When comparing cDNA and DNA as the type of template the analytical sensitivity was in general higher for the protocols using DNA as template regardless of the use of target gene. The analytical specificity for all eight protocols was high. However, some protocols were not able to detect Borrelia spielmanii, Borrelia lusitaniae or Borrelia japonica.
20 July 2017 in European Journal of Clinical Microbiology & Infectious Diseases
For laboratory diagnostics of Lyme neuroborreliosis (LNB), the recomBead Borrelia antibody index (AI) assay has shown promising results in a mixed age population, but has not previously been evaluated with specific focus on paediatric patients. The aim of the study was to evaluate the recomBead Borrelia AI assay in cerebrospinal fluid (CSF) for the laboratory diagnosis of LNB in children. We also wanted to explore whether early markers, such as CXCL13 in CSF and/or total IgM index could be useful as complementary diagnostic tools. Children being evaluated for LNB in a Swedish Lyme endemic area were included in the study (n = 146). Serum and CSF were collected on admission. Patients with other specific diagnoses were controls (n = 15). The recomBead Borrelia AI assay and the recomBead CXCL13 assay (Mikrogen) were applied together with total IgM index. The overall sensitivity for recomBead Borrelia AI (IgM and IgG together) was 74% and the specificity was 97%. However, the highest sensitivity (91%) at an acceptable level of specificity (90%) was obtained by recomBead Borrelia AI together with CXCL13 and total IgM index, showing a positive predictive value of 84% and a negative predictive value of 95%. Thus, the recomBead Borrelia AI assay performs with moderate sensitivity and high specificity in paediatric LNB patients. The major advantage seems to be increased sensitivity in the possible LNB group compared to the IDEIA assay. The diagnostic sensitivity may be further increased by using a combination of early markers, such as CXCL13 in CSF and total IgM index.
9 October 2021 in European Journal of Clinical Microbiology & Infectious Diseases
The chemokine CXCL13 is used as complement to serology in the diagnostics of Lyme neuroborreliosis (LNB). We evaluated and compared the semi-quantitative, cassette-based ReaScan CXCL13 assay with the quantitative recomBead CXCL13 assay using a collection of 209 cerebrospinal fluid samples. The categorical agreement between results interpreted as negative, grey zone, and positive by the two methods was 87%. The diagnostic sensitivity was higher using the recomBead assay, whereas specificity was higher using ReaScan. Few manual steps, and a short turn-around time with no batching of samples makes the ReaScan CXCL13 assay an attractive complement to serology in the diagnostics of LNB.
In Lyme neuroborrelios (LNB), the immune response has been in focus, but the association between different cytokines/chemokines and clinical manifestations in LNB patients has not been fully investigated. The aim of this study was to evaluate a large number of cytokines and chemokines in cerebrospinal fluid (CSF) in relation to diagnosis, clinical presentation and recovery in children being evaluated for LNB. Pediatric patients (n = 105) were recruited at seven Swedish pediatric departments during 2010-14. Serum and CSF samples were drawn on admission, before start of antibiotic treatment. Patients diagnosed as Definite LNB or Possible LNB were categorized as LNBtot patients, all LNBtot patients presented with pleocytosis in CSF. Patients diagnosed as Non-LNB or Other diagnosis were categorized as Controlstot, all controlstot presented without pleocytosis in CSF. Multiplex bead array (Luminex) kits were used for analyses of 41 different cytokines/chemokines in CSF (Millipore). Twenty-eight cytokines/chemokines were detectable in CSF and the levels of 26 of these mediators were significantly higher in LNBtot patients than in Controlstot. In a discriminant analysis, a combination of four cytokines/chemokines (CXCL1, GM-CSF, IL-7 and IL-10) were shown to independently separate relevant patient groups. Furthermore, an IL-10/CXCL1 ratio was created and shown to have an improved diagnostic performance in distinguishing LNBtot vs Non-LNB patients, as compared to CXCL13 in CSF. No immune mediator differed significantly, when comparing LNBtot patients with different clinical presentation on admission or when comparing patients with or without recovery within 2 months of admission. A discriminant analysis was shown to be useful to distinguish the independently most important cytokines/chemokines (CXCL1, GM-CSF, IL-7 and IL-10) in CSF, in order to discriminate LNBtot patients from Non-LNB patients. An IL-10/CXCL1 ratio was shown to have a promising diagnostic profile with a better performance than the chemokine CXCL13 in CSF. However, further evaluation is required to address future possible usefulness of these cytokines and chemokines in laboratory diagnostics in LNB, including control groups with neuro-inflammation. No significant associations were found between CSF immune mediator levels and clinical presentation or recovery in pediatric LNB patients.