Background: Mismatch of intramedullary nails with the bowing of femur is a frequent clinical finding. Previous studies showed inconsistent results. Methods: We present an algorithm of region growing territory method to get the radii of the anterior bowing of femur. We also tested it on ten radiographs. Plain radiographs of the lateral view of femur from five men and five women taken between January and August 2014 in Taipei Hospital were chosen randomly. The curvature of femur outline and medullary canal were measured for three times each. Radii of curvature of whole femur, proximal, middle and distal parts were calculated and analyzed. Results: The coefficient of variation of the 240 measurements ranged from 0.007 to 0.295 and averaged 0.088. The average radii of curvature of the whole, proximal, middle, and distal femur were 1318 mm, 752 mm, 1379 mm, and 599 mm, respectively. At the distal part of the femur, the radius of curvature of the femur outline (452 mm) was smaller than the medullary canal (746 mm) (p < 0.05). Women’s femur was straighter than men’s when we compared the whole length (1435 mm vs. 1201 mm, p < 0.05). The radii we calculated were smaller than the current intramedullary nails. Conclusion: The results showed that the inter-observer and intra-observer differences are acceptable, support the impression that different bowing conditions existed for Asians as compared to Caucasians, and also indicate the mismatch of current instruments to the curvature of femur.
Improper acetabulum component position is a significant risk factor for postoperative dislocation after total hip arthroplasty. Several radiographic two‐dimensional methods exist for measuring acetabulum component anteversion, but they cannot distinguish between anteversion and retroversion. “Liaw's version,” initially proposed as a simple mathematical standardized two‐dimensional method, was modified to the computerized ellipse method, proving superior accuracy to traditional two‐dimensional methods. In this article, we demonstrated its application in detecting and measuring retroverted acetabulum component. We obtained anteroposterior pelvis radiographs from a patient undergoing total hip arthroplasty on the day of surgery and 2 weeks postoperatively. The computerized ellipse method was used to measure the acetabulum component orientation. Upon comparison, the difference between θ assigned to be retroverted (9.52–8.56 = 0.96) is much smaller than the difference between θ assigned to be anteverted (23.81–18.86 = 4.95), leading us to determine retroversion. This was further confirmed by computed tomography at the 6‐week follow‐up. We propose that using the computerized ellipse method to measure Liaw's version can be a valuable tool in identifying acetabulum component retroversion on anteroposterior radiographs during routine postoperative follow‐up and retrospective assessments of total hip arthroplasty patients.
There are many published cup anteversion measurements for postoperative total hip arthroplasty (THA), including Liaw’s, Lewinnek’s, and Murray’s methods. However, most measurements ignore the potential pelvic rotation on radiographs except in Liaw’s method. Without considering pelvic rotation, clinicians can miscalculate cup anteversion. Therefore, we aimed to quantify the mean degree of pelvic rotation. Herein, we collected 388 radiographs of 98 postoperative THA hips of 77 patients and measured pelvic rotation by measuring h, the horizontal displacement of the sacrococcygeal junction associated with the upper pole of the symphysis pubis, and ssd, the distance between the sacrococcygeal junction and pubic symphysis. The angle θ of pelvic rotation was defined as θ = arc sin (h/ssd) × (180°/π). The mean degree of pelvic rotation was then calculated. The standard deviation of h was 7.84 mm, and the mean ssd was 158 mm. The potential pelvic rotation was 2.50°. The p-values from the paired t-test were all >0.05 when interobserver and intraobserver errors were assessed. This is the first study to quantify the potential pelvic rotation in the coronal plane on postoperative plain radiographs. The potential pelvic rotation was too large to be neglected during the measurement of cup anteversion.
Currently, orthopedic surgeons mainly use the inter-teardrop line (IT-line) as the transverse mechanical axis of the pelvis (TAP) for postoperative evaluation of total hip arthroplasty (THA). However, the teardrop is often unclear in the pelvis anteroposterior (AP) radiographs, which makes postoperative evaluation of THA difficult. In this study, we attempted to identify other clear and accurate axes for postoperative evaluation of THA. We calculated the mean and standard deviation of these angles and tested the significance of these angles using t-tests. The inter-teardrops line (IT line) and the upper rim of the obturator foramen (UOF) had smaller angles with the IFH line. The bi-ischial line (BI line) was relatively inaccurate in measurements. We recommend using the IT line as the TAP when the lower boundary of the teardrops is clear and the shapes of the teardrops on both sides of the pelvis are symmetrical. When there is no deformation of the obturator foramen on pelvic AP radiographs, the UOF is also a good choice for the TAP. We do not recommend the BI line as the TAP.
Background and objectives: Treatment of a displaced or comminuted periprosthetic distal femur fracture is challenging, especially in patients with osteoporosis. In this case report, we shared our successful surgical experience of using a long intramedullary fibula bone graft in a plate fixation surgery for a periprosthetic distal femur fracture in an extremely elderly patient with osteoporosis. Case report: A 95-year-old woman with severe osteoporosis (bone mineral density level: −3.0) presented with right knee pain and deformity after a fall, and a right periprosthetic distal femur fracture was identified. The patient underwent an open reduction and an internal plate fixation surgery with the application of a long intramedullary fibular bone graft. Due to a solid fixation, immediate weight-bearing was allowed after the surgery. She could walk independently without any valgus or varus malalignment or shortening 3 months after the surgery. A solid union was achieved 4 months postoperatively. Conclusions: We present a case wherein a long intramedullary allogenous fibula strut bone graft was used successfully to treat a right periprosthetic femur fracture in an extremely elderly patient. A long allogenous fibula bone graft can act not only as a firm structure for bridging the bone defect but also as a guide for precise component alignment. We believe this treatment option for periprosthetic fractures is beneficial for achieving biological and mechanical stability and facilitates early mobilization and weight-bearing for the patient.
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic can be effectively controlled by rapid and accurate identification of SARS-CoV-2-infected cases through large-scale screening. Hypercube pooling polymerase chain reaction (PCR) is frequently used as a pooling technique because of its high speed and efficiency. We attempted to implement the hypercube pooling strategy and found it had a large quantization effect. This raised two questions: is hypercube pooling with edge = 3 actually the optimal strategy? If not, what is the best edge and dimension? We used a C++ program to calculate the expected number of PCR tests per patient for different values of prevalence, edge, and dimension. The results showed that every edge had a best performance range. Then, using C++ again, we created a program to calculate the optimal edge and dimension required for pooling samples when entering prevalence into our program. Our program will be provided as freeware in the hope that it can help governments fight the SARS-CoV-2 pandemic.