Takumi Takeuchi

Dr. Takumi Takeuchi

Kyorin University School of Medicine

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2020 in Spine Surgery and Related Research
Verified
Journal Article
Open access
PDF file
TTTakumi Takeuchi
Takumi Takeuchi
NHNaobumi Hosogane
Naobumi Hosogane
KYKenichiro Yamagishi
Kenichiro Yamagishi
KSKazuhiko Satomi
Kazuhiko Satomi
KMKeitaro Matsukawa
Keitaro Matsukawa
SIShoichi Ichimura
Shoichi Ichimura
IntroductionWe have developed the single or double endplates penetrating screw (SEPS/DEPS) technique, which is a novel percutaneous pedicle screw (PPS) insertion technique suitable for osteoporotic vertebral body fracture (OVF) patients with diffuse idiopathic skeletal hyperostosis (DISH). This study aims to compare the effectiveness of this SEPS/DEPS technique with the conventional pedicle screw technique.MethodsThe screw is inserted upward from the outer caudal side of the pedicle toward the inner cranial side. Vertebrae affected with DISH were inserted with screws using the SEPS/DEPS technique, whereas non-fused vertebrae were inserted with screws using the conventional PPS technique. Twelve OVF patients with DISH were included in this study; three with SEPS/DEPS technique only and nine with a hybrid of both the DEPS and the conventional PPS techniques. As a control group, 12 OVF patients with DISH treated by conventional PPS. The rates of implant failures and of surgical complications were compared between the SEPS/DEPS group and the control group. The insertion torque was measured and compared between DEPS and conventional PPS in three hybrid patients.ResultsIn the SEPS/DEPS group, 70 screws were inserted with the SEPS/DEPS technique and 56 screws were inserted with the conventional PPS technique. In the control group, 116 screws were inserted using the conventional PPS and the PS techniques. The loosening of screws was significantly less in screws inserted with the SEPS/DEPS technique (0/70 screws, 0%) than with screws inserted with the conventional technique (12/116 screws, 10.3%). The average insertion torque of DEPS was 2.25 Nm, which was 134% higher than that of conventional PPS which was 1.64 Nm (p = 0.04).ConclusionThis novel SEPS/DEPS technique has a higher insertion torque compared with the conventional PPS techniques and demonstrated itself to be an effective option for patients with concomitant bone fragility due to DISH.

31 December 2024 in Asian Spine Journal
Verified
Journal Article
Open access
PDF file
KKKazumasa Konishi
Kazumasa Konishi
HSHideto Sano
Hideto Sano
YKYosuke Kawano
Yosuke Kawano
TMTakehiko Moroi
Takehiko Moroi
TTTakumi Takeuchi
Takumi Takeuchi
NHNaobumi Hosogane
Naobumi Hosogane
Study Design: A retrospective study.Purpose: To identify factors involved in surgical site infections (SSIs) after spinal instrumentation surgery performed at a single institution.Overview of Literature: SSIs after spinal instrumentation surgery are a serious complication. Despite reports on risk factors for SSIs in spine surgery, limited studies are related to spinal instrumentation surgery.Methods: In total, 828 patients (338 males and 490 females; mean age, 65.0 years) who underwent spinal instrumentation surgery from 2013 to 2021 in Kyorin University School of Medicine were retrospectively investigated. Patients were divided into the SSI (group I) and non-SSI (group N) groups. Patient characteristics, comorbidity, laboratory, and surgical factors were investigated. Univariate analysis was performed for each item, and multivariate logistic regression analysis was performed for items with significant differences.Results: Fifteen patients (1.85%) had SSIs. Univariate analysis revealed significant differences between groups I and N in history of steroid use, serum albumin, C-reactive protein, number of fixed vertebrae, and perioperative blood transfusion. Multivariate logistic regression analysis showed that a history of steroid use (odds ratio [OR], 5.38; 95% confidence interval [CI], 1.41–20.49; p=0.014), serum albumin (OR, 0.34; 95% CI, 0.13–0.84; p=0.020), and perioperative blood transfusion (OR, 5.85; 95% CI, 1.46–23.50; p=0.013) were independent risk factors for SSIs.Conclusions: The results of this study indicate that preoperative nutritional intervention, appropriate management of anemia, and intraoperative and postoperative bleeding control may decrease the incidence of SSIs. However, this study has several limitations, including its retrospective design, analysis of a few SSI cases, and inclusion of various surgical approaches and disease types. Future studies that address these limitations are desirable.

26 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TTTakumi Takeuchi
Takumi Takeuchi
KYKenichiro Yamagishi
Kenichiro Yamagishi
KKKazumasa Konishi
Kazumasa Konishi
HSHideto Sano
Hideto Sano
MTMasato Takahashi
Masato Takahashi
NHNaobumi Hosogane
Naobumi Hosogane
The combined anteroposterior fusion with vertebral body replacement (VBR) using a wide footplate expandable cage with a minimally invasive lateral approach has been widely used for pseudoarthrosis after osteoporotic vertebral fractures. The purpose of this study is to evaluate the radiological results of combined anteroposterior surgery using VBR and to recommend the optimal procedure. Thirty-eight elderly patients were included in this study. The mean preoperative local kyphosis angle was 29.3°, and the mean correction loss angle was 6.3°. Cage subsidence was observed in ten patients (26.3%), and UIV or LIV fracture in twelve patients (31.6%). Patients with cage subsidence were compared to those without cage subsidence to determine the causal factors. The mean number of fixed vertebrae was 5.4 vertebrae with cage subsidence and 7.4 vertebrae without cage subsidence. In addition, to precisely clarify the optimal number of fixed vertebrae, those patients with two above–two below fixation were compared to those with less than two above–two below fixation, which revealed that the correction loss angle was significantly less in two above–two below fixation (p = 0.016). Based on these results, we recommend at least two above–two below fixation with VBR to minimize the correction loss angle and prevent cage subsidence.

13 October 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
STShinji Takahashi
Shinji Takahashi
SIShota Ichikawa
Shota Ichikawa
KWKei Watanabe
Kei Watanabe
HUHaruki Ueda
Haruki Ueda
HAHideyuki Arima
Hideyuki Arima
Shoji SekiShoji Seki
Shoji Seki
Background/Objectives: The clinical management of adolescent idiopathic scoliosis (AIS) is hindered by the inability to accurately predict curve progression. Although skeletal maturity and the initial Cobb angle are established predictors of progression, their combined predictive accuracy remains limited. This study aimed to develop a robust and interpretable artificial intelligence (AI) system using deep learning (DL) models to predict the progression of scoliosis using only standing frontal radiographs. Methods: We conducted a multicenter study involving 542 patients with AIS. After excluding 52 borderline progression cases (6–9° progression in the Cobb angle), 294 and 196 patients were assigned to progression (≥10° increase) and non-progression (≤5° increase) groups, respectively, considering a 2-year follow-up. Frontal whole spinal radiographs were preprocessed using histogram equalization and divided into two regions of interest (ROIs) (ROI 1, skull base–femoral head; ROI 2, C7–iliac crest). Six pretrained DL models, including convolutional neural networks (CNNs) and transformer-based models, were trained on the radiograph images. Gradient-weighted class activation mapping (Grad-CAM) was further performed for model interpretation. Results: Ensemble models outperformed individual ones, with the average ensemble model achieving area under the curve (AUC) values of 0.769 for ROI 1 and 0.755 for ROI 2. Grad-CAM revealed that the CNNs tended to focus on the local curve apex, whereas the transformer-based models demonstrated global attention across the spine, ribs, and pelvis. Models trained on ROI 2 performed comparably with respect to those using ROI 1, supporting the feasibility of image standardization without a loss of accuracy. Conclusions: This study establishes the clinical potential of transformer-based DL models for predicting the progression of scoliosis using only plain radiographs. Our multicenter approach, high AUC values, and interpretable architectures support the integration of AI into clinical decision-making for the early treatment of AIS.

29 February 2024 in Asian Spine Journal
Verified
Journal Article
Open access
PDF file
TTTakumi Takeuchi
Takumi Takeuchi
YTYuhei Takamizawa
Yuhei Takamizawa
KKKazumasa Konishi
Kazumasa Konishi
HSHideto Sano
Hideto Sano
MTMasahito Takahashi
Masahito Takahashi
NHNaobumi Hosogane
Naobumi Hosogane
Study Design: This is a finite element (FE) study.Purpose: To compare the fixation strength of traditional trajectory (TT) and single and double endplate penetrating screw trajectories (SEPST/DEPST) to the osteoporotic vertebral body model based on the FE method.Overview of Literature: SEPST/DEPST have been developed to enhance the fixation strength in patients with diffuse idiopathic hyperostosis (DISH). This technique was also applied to patients with osteoporosis. However, determining the superiority of SEPST/ DEPST is difficult because of the heterogeneous patient backgrounds.Methods: Twenty vertebrae (T12 and L1) from 10 patients with osteoporosis (two males and eight females; mean age, 74.7 years) were obtained to create the 10 FE models. First, a single screw was placed with TT and SEPST/DEPST, and the fixation strength was compared by axial pullout strength (POS) and multidirectional loading tests. Second, two screws were placed on the bilateral pedicles with TT and SEPST/DEPST, and the fixation force of the vertebrae in the constructs in flexion, extension, lateral flexion, and axial rotation was examined.Results: SEPST and DEPST had 140% and 171% higher POS values than TT, respectively, and the DEPST result was statistically significant (p =0.007). The multidirectional fixation strength was significantly higher in DEPST and SEPST than in TT in the cranial, caudal, and medial directions (p <0.05) but not in the lateral direction (p =0.05). The vertebral fracture strength at the lower instrumented vertebra of the DEPST tended to be higher than that of TT. The vertebral motion angles in SEPST and DEPST were significantly smaller in lateral bending (p =0.02) and tended to be smaller in flexion and extension than in TT (p =0.13).Conclusions: This study may provide useful information for spine surgeons in deciding whether to choose the SEPS or DEPS technique for augmenting fixation in osteoporotic vertebral fracture surgery.

12 November 2017 in Behavioural Neurology
Verified
Journal Article
Open access
PDF file
TTTakumi Takeuchi
Takumi Takeuchi
MTMasahito Takahashi
Masahito Takahashi
KSKazuhiko Satomi
Kazuhiko Satomi
HOHideaki Ohne
Hideaki Ohne
AHAtsushi Hasegawa
Atsushi Hasegawa
SIShoichi Ichimura
Shoichi Ichimura
The objective of this study was to electrophysiologically assess the corticospinal tracts of adult rats and the recovery of motor function of their forelimbs after cervical cord hemisection. Of 39 adult rats used, compound muscle action potentials (CMAPs) of the forelimbs of 15 rats were evaluated, before they received left C5 segmental hemisection of the spinal cord, by stimulating the pyramid of the medulla oblongata on one side using an exciting microelectrode. All 15 rats exhibited contralateral electrical activity, but their CMAPs disappeared after hemisection. The remaining 24 rats received hemisection first, and CMAPs of 12 rats were assessed over time to study their recovery time. All of them exhibited electrical activity of the forelimbs in 4 weeks after surgery. The remaining 12 rats received additional right C2 segmental hemisection, and variation of CMAPs between before and after surgery was examined. The right side of the 12 rats that received the additional hemisection exhibited no electrical activity in response to the stimulation of the pyramids on both sides. These results suggest that changes in path between the resected and healthy sides, activation of the ventral corticospinal tracts, and propriospinal neurons were involved in the recovery of motor function after cervical cord injury.