Faiz Husnayain

Dr. Faiz Husnayain

Electrical Engineering Department, Universitas Indonesia, Depok, Jawa Barat, Indonesia
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
DAD R Aryani
D R Aryani
TKT A Khairurraziq
T A Khairurraziq
GRG R Ramadhan
G R Ramadhan
NWN S Wardana
N S Wardana
FHFaiz Husnayain
Faiz Husnayain
IGI Garniwa
I Garniwa
The implementation of photovoltaic (PV) system has been evolving all over the world as the alternative energy sources are getting more required. However, the construction of PV power plants on the ground would need a large space. In regions which are lack of sites for the ground PV installation, a floating PV system is one of the solutions. This study analyses the performance of floating PV in supplying power to loads with a battery as the energy storage in a stand-alone system. The system is simulated using small capacities of PV module, battery, and load, where all components are integrated using a solar charge controller to maintain a safe operation. The performance of floating PV is compared to the ground PV in terms of the capacity factor, conversion efficiency, and operating efficiency. The average of capacity factor and conversion efficiency of floating PV is 1.53% and 0.79% higher than the ground PV respectively. Meanwhile, in terms of operating efficiency, floating PV is 1.48% more effective compared to the ground PV. One can notice that the floating PV provides better power efficiency compared to ground PV as the cell temperature is maintained well in an optimal circumstance.

1 June 2019
Verified
Conference Paper
Closed access
MFMuhammad Alif Fatullah
Muhammad Alif Fatullah
ARAmien Rahardjo
Amien Rahardjo
FHFaiz Husnayain
Faiz Husnayain
There are two factors that affects battery capacity, ambient temperature and discharge rate. Ambient temperature can affect battery parameters such as voltage, capacity and battery life. Battery discharge current is influenced by the load associated with the battery. The load used needs to be adjusted to the battery capacity that will be used so that the discharge current produced by the battery is in accordance with its rating of use as the discharge flow generated by the battery can affect the battery’s capacity. Therefore, research on the effect of environmental temperature and current discharge on lead-acid batteries with a deep-discharge method is required to see the battery capacity at different ambient and discharge temperatures. From the research that have been carried out, the capacity ratio is directly proportional to the ambient temperature and inversely proportional to the battery discharge current. For example, on 30°C test, battery capacity at 2 Ohms, 3 Ohms and 4 Ohms respectively are 57.783, 58.74 and 60.467 Wh. Another example is on 2 Ohm load, battery capacity at 30°C, 40°C and 50°C are 57.783, 58.175 and 58.213 Wh respectively.

1 August 2015
Verified
Conference Paper
Closed access
FHFaiz Husnayain
Faiz Husnayain
MLM. Latif
M. Latif
IGI. Garniwa
I. Garniwa
In the power generation, transmission or distribution of electricity, transformer is one of the most valuable and important asset. The transformer reliability is very dependent on the quality of the insulation system. During the operational phase transformer, transformer oil will undergo degradation or deterioration due to high temperatures and chemical reactions that occur as oxidation. Aging in insulating oils would also affect its characteristics, such as physical and electrical properties, as well as lowering the lifetime of the insulation. This paper discusses the aging of insulation oil. Research on accelerated thermal aging was conducted to determine the behavior of insulating oil deterioration Nynas Nytro 10X and predict future use. Based on the Arrhenius law, if the temperature of transformer oil samples were operating normally in 60°C, the lifetime prediction of insulating oil will be 697.079 hours. Furthermore, the percentage decrease in the lifetime prediction isolation transformer IBT CBN S phase at normal loading conditions, the imposition of emergency at long time, as well as the emergency at short time in a row at 0.002032%, 0.047435% and 0.957268% of the rest period normal to the insulation of 5.5 years.

25 May 2020 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
AIAgus Indarto
Agus Indarto
AMArdhyan Wisnu Murti
Ardhyan Wisnu Murti
FHFaiz Husnayain
Faiz Husnayain
IGIwa Garniwa
Iwa Garniwa
ARAmien Rahardjo
Amien Rahardjo
CHChairul Hudaya
Chairul Hudaya
In this study, 238 power transformers (PTs) with operating voltages between 150­500 kV and capacities in the range of 60–167 MVA are tested for partial discharge (PD). Thirty-eight of the PTs exceeded the pre-determined value of 70 pC at 1.5 maximum voltage of the PT. Failure analysis of the failed 38 PTs showed that 21% of the PD sources originate from the winding cylinder, which is formed by bonding the edges of a pressboard with an adhesive. Therefore, in this study, the effect of casein- and polyvinyl-based adhesives used in winding cylinders was investigated through standard PD measurements. The results indicate that pressboards bonded with casein-based adhesives exhibit PD values 20–25 pC lower than those bonded with polyvinyl-based adhesives (50–400 pC) at identical applied voltages (7.5–25 kV or 3–10 kV/mm). The excellent performance of casein-based adhesives is mainly attributed to its porous structure, which accelerates the impregnation of oil into the adhesive and pressboard, as revealed by scanning electron microscopy observations. This practical study will be beneficial in the process of designing and manufacturing PTs and highlight materials for producing PTs with low PD values.

1 November 2014
Verified
Conference Paper
Closed access
FHFaiz Husnayain
Faiz Husnayain
NPN. D. Purnomo
N. D. Purnomo
RAR. Anwar
R. Anwar
IGI. Garniwa
I. Garniwa
Propose of this study is to analyze power system profile especially harmonic at one of Offshore Platform in Indonesia. Field survey was conducted and found that total harmonic distortion (THD) both of voltage and current exceed limitation as recommended in IEEE 519-1992, THD-i 11.76% ZU A, 11.29% ZUD, 31.11% ZUG, and unbalance load exceed 5%. Analysis using ETAP 12.6 shows harmonic reduction could be achieved by installing multi-tuned passive harmonic filters. However, since the result of actual measurement shows unbalance power flow that reflect the dynamic impedance on the network system, therefore the passive filter would not effective to reduce harmonics. On the other case active filter type is not sensitive on dynamic impedance, due to its internal controller capable to compensate and cancel harmonic currents in any condition. Based on the above considerations, it is recommended to install a line reactor on each VFD and active harmonic filter on respective Point of Common Coupling (PCC) with sizing 60A and 4% in ZUA; 75A and 4% in ZUD and 120A and 3% impedance in ZUG for active filter and line reactor impedance respectively. The final THD-i in each NUI as follow 5.87%, 4.95% and 6.65%.

1 June 2019
Verified
Conference Paper
Closed access
MHMuhammad Daffa El Hakim
Muhammad Daffa El Hakim
AKAgustinus Aditya Budi Kusuma
Agustinus Aditya Budi Kusuma
DADwi Riana Aryani
Dwi Riana Aryani
FJFauzan Hanif Jufri
Fauzan Hanif Jufri
FHFaiz Husnayain
Faiz Husnayain
AUAgus R. Utomo
Agus R. Utomo
Practically, the photovoltaic system has an average efficiency of around 15-20%. With this range of value, it is highly recommended for the system to gain the maximum efficiency possible. This paper consists of load-flow study that aims to analyze the optimum location for solar PV implementation by evaluating the voltage drop of the examined system. The study is performed by modeling the power system of the Lombok electrical network. Afterward, a 10 MWp PV solar plant is integrated at several points in either transmission or distribution bus. This study is carried out by the ETAP program to calculate and process the data based on the Newton-Raphson method. The result of the data processing shows that the best interconnection for PV implementation on grid-solar power plan interconnected system located in Lombok is on GI Mantang substation. That 150-kV bus area is the most optimum location to integrate the PV system with the grid system with the voltage drop appeared on that bus is 1.471%.