Jasmine Nindra

Dr. Jasmine Nindra

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JNJasmine Nindra
Jasmine Nindra
MSManinder Singh Sidhu
Maninder Singh Sidhu
AKAnuraj Kochhar
Anuraj Kochhar
ADAshish Dabas
Ashish Dabas
Rosa VallettaRosa Valletta
Rosa Valletta
Gianrico SpagnuoloGianrico Spagnuolo
Gianrico Spagnuolo
The purpose of the present retrospective observational study was to compare the effects of treatment with Herbst appliance and fixed therapy with elastics on the condyle and glenoid fossa complex. Thirty patients aged between twelve and sixteen years with skeletal Class II malocclusion who met the inclusion criteria were included in the study: fifteen patients treated with Herbst appliance (Group 1), and fifteen patients treated with orthodontic camouflage using MBT prescription (MBTTM Versatile+ Appliance System) (Group 2). For Group 2, patients had CBCT scans taken before treatment either after Herbst appliance removal or at the end of treatment. CBCT scans were evaluated for changes in condyle-glenoid fossa complex using the In Vivo Dental 5.1 software. Statistical significance was set at p ≤ 0.05. On inter-group comparison, the Herbst group showed statistically significant increases in the condylar height of 1.35 mm (p ≤ 0.001) on the right and 1.21 mm (p ≤ 0.01) on the left side, and a condylar volume of 111.03 mm3 (p ≤ 0.01) on the right and 127.80 mm3 (p ≤ 0.001) on the left side. The Herbst group showed anterior remodelling on the postero-superior aspect of glenoid fossa. Herbst appliance treatment induced growth at the condylar head and anterior remodelling of glenoid fossa, thereby improving the maxilla-mandibular relationship in growing skeletal Class II patients.

28 February 2023 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
SASuman Arora
Suman Arora
SGSeema Grover
Seema Grover
PHPandurangan Harikrishnan
Pandurangan Harikrishnan
ADAshish Dabas
Ashish Dabas
NDNamrata Dogra
Namrata Dogra
JNJasmine Nindra
Jasmine Nindra

30 October 2023 in INTERNATIONAL JOURNAL OF EXPERIMENTAL RESEARCH AND REVIEW
Verified
Journal Article
Open access
PDF file
GPGananjay Patil
Gananjay Patil
SKSantosh Kumar
Santosh Kumar
NDNamrata Dogra
Namrata Dogra
JNJasmine Nindra
Jasmine Nindra
SKSatwashila Kadam
Satwashila Kadam
KYKrishna Yadav
Krishna Yadav
The study aims to test the effects of LED light at three different power settings (500mW/cm2, 1000mW/cm2& 1500m W/cm2) and three different exposure times (5sec, 10sec & 20sec) adhesive composites for use with stainless steel orthodontic brackets, and their shear bond strengths. Current In-vitro work used 120 teeth, mostly premolars, separated into 10 equal groups of 12. After the crowns of the teeth were exposed by mounting them vertically into self-heal acrylics, the buccal-enamel exterior was prepared for bonding (PEA) 0.022”x 0.028” stainless steel premolar bracket using a thin layer of light cure adhesive primer and paste (Transbond-XT-3M Unitek Monrovia, Calif). Brackets in Group 1 comprising the Control group treated by usual halogen light source for forty sec, in remaining 9 groups (Experimental group) three commercially available LED curing light units i.e., Woodpecker, Guilin, Guangxi, China; Stealth Soft Equinox, Denmark, Holland; Radii plus, SDI, Australia, having three different light intensity 500mW/cm2, 1000mW/cm2, 1500mW/cm2 respectively were used to bond the brackets at three contact time (5/10/20 sec). The universal testing equipment was used to determine the shear bond strength of each specimen. The uppermost average SBS was found in the group cured with LED of intensity 1500 mW/cm2 for 20 sec (20.08 + 4.82 MPa) which was statistically significant compared the to control group (12.72 + 2.42 MPa). The lowest mean SBS values were obtained for groups cured with LED of intensity 500 mW/cm2 even at different curing times of 5, 10 and 20 sec i.e., 5.46 + 1.99 MPa, 8.77 + 2.38 Mpa and 11.24 + 2.59 MPa, respectively. Increasing the intensity of the LED light curing unit provides a clinically acceptable SBS even after reducing the curing times, thereby reducing the chairside time for bonding of orthodontic brackets.The study aims to test the effects of LED light at three different power settings (500mW/cm2, 1000mW/cm2& 1500m W/cm2) and three different exposure times (5sec, 10sec & 20sec) adhesive composites for use with stainless steel orthodontic brackets, and their shear bond strengths. Current In-vitro work used 120 teeth, mostly premolars, separated into 10 equal groups of 12. After the crowns of the teeth were exposed by mounting them vertically into self-heal acrylics, the buccal-enamel exterior was prepared for bonding (PEA) 0.022”x 0.028” stainless steel premolar bracket using a thin layer of light cure adhesive primer and paste (Transbond-XT-3M Unitek Monrovia, Calif). Brackets in Group 1 comprising the Control group treated by usual halogen light source for forty sec, in remaining 9 groups (Experimental group) three commercially available LED curing light units i.e., Woodpecker, Guilin, Guangxi, China; Stealth Soft Equinox, Denmark, Holland; Radii plus, SDI, Australia, having three different light intensity 500mW/cm2, 1000mW/cm2, 1500mW/cm2 respectively were used to bond the brackets at three contact time (5/10/20 sec). The universal testing equipment was used to determine the shear bond strength of each specimen. The uppermost average SBS was found in the group cured with LED of intensity 1500 mW/cm2 for 20 sec (20.08 + 4.82 MPa) which was statistically significant compared the to control group (12.72 + 2.42 MPa). The lowest mean SBS values were obtained for groups cured with LED of intensity 500 mW/cm2 even at different curing times of 5, 10 and 20 sec i.e., 5.46 + 1.99 MPa, 8.77 + 2.38 Mpa and 11.24 + 2.59 MPa, respectively. Increasing the intensity of the LED light curing unit provides a clinically acceptable SBS even after reducing the curing times, thereby reducing the chairside time for bonding of orthodontic brackets.