Martina Manfredi

Dr. Martina Manfredi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2020 in Veterinary Surgery
Verified
Journal Article
Closed access
PDF file
RFRoberta Ferrari
Roberta Ferrari
LCLavinia Elena Chiti
Lavinia Elena Chiti
MMMartina Manfredi
Martina Manfredi
GRGiuliano Ravasio
Giuliano Ravasio
DZDonatella De Zani
Donatella De Zani
DSDamiano Stefanello
Damiano Stefanello

15 February 2021 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
AMAurora Magliocca
Aurora Magliocca
Emanuele RezoagliEmanuele Rezoagli
Emanuele Rezoagli
DZDavide Zani
Davide Zani
MMMartina Manfredi
Martina Manfredi
DGDaria De Giorgio
Daria De Giorgio
GRGiuseppe Ristagno
Giuseppe Ristagno
Rationale: Cardiopulmonary resuscitation is the cornerstone of cardiac arrest (CA) treatment. However, lung injuries associated with it have been reported. Objectives: To assess 1) the presence and characteristics of lung abnormalities induced by cardiopulmonary resuscitation and 2) the role of mechanical and manual chest compression (CC) in its development. Methods: This translational study included 1) a porcine model of CA and cardiopulmonary resuscitation (n = 12) and 2) a multicenter cohort of patients with out-of-hospital CA undergoing mechanical or manual CC (n = 52). Lung computed tomography performed after resuscitation was assessed qualitatively and quantitatively along with respiratory mechanics and gas exchanges. Measurements and Main Results: The lung weight in the mechanical CC group was higher compared with the manual CC group in the experimental (431 ± 127 vs. 273 ± 66, P = 0.022) and clinical study (1,208 ± 630 vs. 837 ± 306, P = 0.006). The mechanical CC group showed significantly lower oxygenation (P = 0.043) and respiratory system compliance (P < 0.001) compared with the manual CC group in the experimental study. The variation of right atrial pressure was significantly higher in the mechanical compared with the manual CC group (54 ± 11 vs. 31 ± 6 mm Hg, P = 0.001) and significantly correlated with lung weight (r = 0.686, P = 0.026) and respiratory system compliance (r = −0.634, P = 0.027). Incidence of abnormal lung density was higher in patients treated with mechanical compared with manual CC (37% vs. 8%, P = 0.018). Conclusions: This study demonstrated the presence of cardiopulmonary resuscitation–associated lung edema in animals and in patients with out-of-hospital CA, which is more pronounced after mechanical as opposed to manual CC and correlates with higher swings of right atrial pressure during CC.

8 January 2019 in Journal of the American Heart Association
Verified
Journal Article
Open access
AMAurora Magliocca
Aurora Magliocca
DODavide Olivari
Davide Olivari
DGDaria De Giorgio
Daria De Giorgio
DZDavide Zani
Davide Zani
MMMartina Manfredi
Martina Manfredi
GRGiuseppe Ristagno
Giuseppe Ristagno
Background: Mechanical chest compression (CC) is currently suggested to deliver sustained high‐quality CC in a moving ambulance. This study compared the hemodynamic support provided by a mechanical piston device or manual CC during ambulance transport in a porcine model of cardiopulmonary resuscitation. Methods and Results: In a simulated urban ambulance transport, 16 pigs in cardiac arrest were randomized to 18 minutes of mechanical CC with the LUCAS (n=8) or manual CC (n=8). ECG, arterial and right atrial pressure, together with end‐tidal CO 2 and transthoracic impedance curve were continuously recorded. Arterial lactate was assessed during cardiopulmonary resuscitation and after resuscitation. During the initial 3 minutes of cardiopulmonary resuscitation, the ambulance was stationary, while then proceeded along a predefined itinerary. When the ambulance was stationary, CC‐generated hemodynamics were equivalent in the 2 groups. However, during ambulance transport, arterial and coronary perfusion pressure, and end‐tidal CO 2 were significantly higher with mechanical CC compared with manual CC (coronary perfusion pressure: 43±4 versus 18±4 mmHg; end‐tidal CO 2 : 31±2 versus 19±2 mmHg, P <0.01 at 18 minutes). During cardiopulmonary resuscitation, arterial lactate was lower with mechanical CC compared with manual CC (6.6±0.4 versus 8.2±0.5 mmol/L, P <0.01). During transport, mechanical CC showed greater constancy compared with the manual CC, as represented by a higher CC fraction and a lower transthoracic impedance curve variability ( P <0.01). All animals in the mechanical CC group and 6 (75%) in the manual one were successfully resuscitated. Conclusions: This model adds evidence in favor of the use of mechanical devices to provide ongoing high‐quality CC and tissue perfusion during ambulance transport.

22 April 2021 in Veterinary and Comparative Oncology
Verified
Journal Article
Closed access
PDF file
LCLavinia Elena Chiti
Lavinia Elena Chiti
DSDamiano Stefanello
Damiano Stefanello
MMMartina Manfredi
Martina Manfredi
DZDavide D. Zani
Davide D. Zani
DZDonatella De Zani
Donatella De Zani
RFRoberta Ferrari
Roberta Ferrari

18 November 2021 in Veterinary Radiology & Ultrasound
Verified
Journal Article
Open access
PDF file
MBMara Bagardi
Mara Bagardi
CLChiara Locatelli
Chiara Locatelli
MMMartina Manfredi
Martina Manfredi
JBJessica Bassi
Jessica Bassi
CSCarlotta Spediacci
Carlotta Spediacci
PBPaola G. Brambilla
Paola G. Brambilla
Cavalier King Charles Spaniels (CKCS) are predisposed to developing myxomatous mitral valve disease (MMVD), with radiographs frequently used to screen for evidence of left‐sided cardiomegaly secondary to MMVD. Vertebral heart size (VHS), vertebral left atrial size (VLAS), modified VLAS (M‐VLAS), and radiographic left atrial dimension (RLAD) are reported as objective measurements of global heart size and left atrial size. Normal VHS in CKCS (10.6 ± 0.5) is reportedly higher than the non‐breed‐specific value (9.7±0.5). Breed‐specific VLAS, M‐VLAS, and RLAD cut‐offs have not been reported in CKCS. The aim of this prospective reference interval study was to describe the VHS, VLAS, M‐VLAS, and RLAD values for 30 clinically healthy adult CKCS. Inclusion criteria were unremarkable physical examination, normal echocardiography, and thoracic radiographs without malposition/abnormalities. There were 22 female and eight male dogs. Ages ranged from 1 to 6 years. The VHS mean value in our sample was 10.08 ± 0.56 (95% range, 9.87‐10.29). This was significantly greater than a previously published general canine reference value of 9.7 ± 0.5 and significantly less than a previously published CKCS breed‐specific value of 10.6 ± 0.5 (P < 0.01). Mean VLAS, M‐VLAS, and the RLAD values in our study were 1.79 ± 0.3 (95% range, 1.68‐1.9), 2.23 ± 0.44 (95% range, 2.06‐2.39), and 1.2 ± 0.34 (95% range, 1.07‐1.33), respectively. These were significantly less than previously published reference interval values (P < 0.001). The VHS, M‐VLAS, and the RLAD were not affected by sex, body weight, or BCS; whereas the VLAS was moderately affected by body weight. Findings from this study can be used as background for future thoracic radiographic assessments in CKCS.

15 June 2021 in Veterinary Radiology & Ultrasound
Verified
Journal Article
Open access
PDF file
MMMartina Manfredi
Martina Manfredi
DZDonatella De Zani
Donatella De Zani
LCLavinia Elena Chiti
Lavinia Elena Chiti
RFRoberta Ferrari
Roberta Ferrari
DSDamiano Stefanello
Damiano Stefanello
DZDavide Danilo Zani
Davide Danilo Zani
Sentinel lymph node (SLN) mapping is the current gold standard for the oncological staging of solid malignancies in humans. This prospective observational study describes the feasibility and the limits of preoperative lymphoscintigraphy for SLN detection in dogs with spontaneous malignancies and the improvements in staging accuracy. Client‐owned dogs with confirmed malignant neoplasia and absence of distant metastasis were prospectively enrolled. Lymphoscintigraphy was performed after the peritumoral injection of Technetium‐99m labeled nanocolloids. Regional dynamic and static images were acquired, with and without masking of the injection site with a lead shield. The dogs were then subjected to surgery for tumor excision and SLN extirpation. Intraoperative SLN detection was performed by combining methylene blue dye and a dedicated gamma probe. Overall, 51 dogs with a total of 60 solid malignant tumors were enrolled. Lymphoscintigraphy identified at least one SLN in 57 of 60 cases (95%). The SLN did not always correspond to the regional lymph node (35/57, 61.4%). The use of a lead shield, masking the injection site, markedly improved the SLN visibility. The median time of SLN appearance was 11.4 ± 9.3 min. No side effects were observed. Preoperative lymphoscintigraphy allows for SLN detection in dogs and can improve staging accuracy by either identifying the SLN in a different lymphosome than clinically expected or discriminating the draining node in uncertain cases. The combined use of preoperative and intraoperative techniques is recommended to increase the SLN detection rate.