Hyun-Jae Lee

Mr. Hyun-Jae Lee

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
HLHyun-Jae Lee
Hyun-Jae Lee
JSJingeun Shon
Jingeun Shon
This paper presents an improved voltage flux-weakening strategy of a permanent magnet synchronous motor (PMSM) in a high-speed operation. The speed control performance using voltage flux-weakening control is not affected by the motor parameters, so it is used in various motors for high-speed operations. In general, the voltage flux-weakening control uses voltage references to generate a flux axis current reference. However, there may be errors between the voltage reference and the actual voltage flowing into the motor. This causes an error in the current reference generation and reduces the efficiency of the inverter and motor due to the use of more current. In this paper, the problems that can occur due to voltage errors were analyzed through theoretical approaches and simulations, and improved voltage flux-weakening control to resolve these problems was presented. This method’s advantage is that the error between the voltage reference and the voltage applied to the motor can be minimized, and the target speed can be reached with minimum current. As a result, it was possible to increase the energy efficiency by reducing the amount of current flowing through the motor. The effect of the improved voltage-based flux-weakening control method was verified through simulations and experiments. As a result, the voltage errors were reduced by approximately 2.16% compared to the general method. Moreover, the current used in the field-weakening control region was reduced by up to 27.17% under the same torque condition.

30 June 2023 in IEEE Access
Verified
Journal Article
Open access
HLHyun-Jae Lee
Hyun-Jae Lee
JSJingeun Shon
Jingeun Shon
This paper introduces a novel non-integral method for calculating AC capacitor voltage in shunt hybrid active power filters (SHAPFs). These filters commonly use passive power filters (PPFs) that can introduce voltage containing harmonics into the AC capacitor, leading to overvoltage situations that can be dangerous. To avoid accidents due to overvoltage, it is necessary to monitor the AC capacitor voltage continuously. The proposed method enables the calculation of the voltage across the AC capacitor, using only the sensor available in the SHAPF, without requiring additional sensors. By avoiding the use of integration to calculate the voltage, the method effectively mitigates errors due to DC offset inflows. The effectiveness of the proposed method was verified through simulations and actual experiments. Results demonstrate that the proposed voltage calculation method improves the voltage calculation accuracy by approximately 1.93[%] when compared to the general voltage calculation method. The proposed non-integral AC capacitor voltage calculation method represents a significant advancement for SHAPFs, providing an effective means for reducing overvoltage risks, without requiring additional sensors or costly equipment.

13 February 2023 in IEEE Access
Verified
Journal Article
Open access
HLHyun-Jae Lee
Hyun-Jae Lee
JSJingeun Shon
Jingeun Shon
This study presents a method for monitoring the voltage across the AC capacitor in a grid-connected hybrid active power filter without the use of additional voltage sensors. In the case of an AC capacitor used in a hybrid, active power filter, there is a risk of burnout caused by exceeding the allowable voltage owing to the harmonic current and voltage generated by the inverter. Therefore, this study presents a method to monitor the voltage of the AC capacitor using the current from which the DC component has been removed without any additional voltage sensors to prevent the burn-out of the AC capacitor. The proposed sensorless AC capacitor voltage monitoring method is verified through simulations and experiments. The difference between the magnitude of the voltage measured in the simulations and experiments and the magnitude of the voltage predicted with the proposed method was approximately 0.526[%] on average.

16 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
JHJeongwon HAN
Jeongwon HAN
HLHyun-Jae Lee
Hyun-Jae Lee
JSJingeun Shon
Jingeun Shon
This paper proposes a new maximum power point tracking (MPPT) method based on machine learning with improved power production efficiency for application to photovoltaic (PV) systems. Power loss occurs in the incremental conductance (InC) method, depending on the size of the voltage step used to track the maximum power point. Additionally, the size of the voltage step must be specified by the initial user; however, an appropriate size cannot be determined in a rapidly changing environment. To solve this problem, this study presents a gradient descent InC (GD InC) method that optimizes the size of the voltage step by applying an optimization method based on machine learning. The effectiveness of the GD InC method was verified and the optimized size of the voltage step was confirmed to produce the largest amount of power. When the size of the voltage step was optimized, a maximum difference of 4.53% was observed compared with the case when the smallest amount of power was produced. The effectiveness of the GD InC method, which improved the efficiency of power production by optimizing the size of the voltage step, was verified. Power can be produced efficiently by applying the GD InC method to PV systems.

7 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
HLHyun-Jae Lee
Hyun-Jae Lee
Gunbok LeeGunbok Lee
Gunbok Lee
GKGildong Kim
Gildong Kim
JSJingeun Shon
Jingeun Shon
This study presents a variable incremental controller for flux-weakening control in the high-speed operation area of a permanent-magnetic synchronous motor (PMSM). In general, voltage-based flux-weakening control utilizes a reference voltage and a PI controller to generate a flux component current. In this paper, the voltage-based flux-weakening control is performed using the variable incremental controller instead of the PI controller. The variable incremental controller can control the flux component current using only the maximum speed and maximum current of the motor. A method for properly setting an appropriate variable incremental controller using acceleration is additionally presented. A variable incremental controller is applied and, accordingly, the overshoot of the motor speed can be reduced and the speed error of the motor can be minimized by reducing the difference between the actual motor and targeted accelerations. This method can simplify the design of a controller that utilizes flux-weakening control and can be applied to railroad cars whose acceleration does not alter frequently to increase the effect of motor control.

29 August 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
HLHyun-Jae Lee
Hyun-Jae Lee
JSJingeun Shon
Jingeun Shon